Subcutaneous tissue reaction and cytotoxicity of polyvinylidene fluoride and polyvinylidene fluoride-trifluoroethylene blends associated with natural polymers

被引:17
作者
Marques, Leonardo [1 ]
Holgado, Leandro A. [1 ]
Simoes, Rebeca D. [2 ]
Pereira, Joao D. A. S. [2 ]
Floriano, Juliana F. [3 ]
Mota, Ligia S. L. S. [4 ]
Graeff, Carlos F. O. [3 ]
Constantino, Carlos J. L. [2 ]
Rodriguez-Perez, Miguel A. [5 ]
Matsumoto, Mariza [1 ]
Kinoshita, Angela [1 ]
机构
[1] Univ Sagrado Coracao USC, Sao Paulo, Brazil
[2] UNESP Univ Estadual Paulista, Fac Ciencias & Tecnol, Sao Paulo, Brazil
[3] UNESP Univ Estadual Paulista, Fac Ciencias, Sao Paulo, Brazil
[4] UNESP Univ Estadual Paulista, Inst Biociencias, Sao Paulo, Brazil
[5] Univ Valladolid, CellMat Lab, Fac Sci, Dept Condensed Matter Phys, Valladolid, Spain
基金
巴西圣保罗研究基金会;
关键词
biomaterial; piezoelectricity; tissue reaction; cytotoxicity; PVDF; MINERAL TRIOXIDE AGGREGATE; IN-VITRO BIOCOMPATIBILITY; PVDF; BONE; RESPONSES; STARCH; RUBBER; MESHES; PIEZOELECTRICITY; BIOMATERIALS;
D O I
10.1002/jbm.b.32941
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cytotoxicity and subcutaneous tissue reaction of innovative blends composed by polyvinylidene fluoride and polyvinylidene fluoride-trifluoroethylene associated with natural polymers (natural rubber and native starch) forming membranes were evaluated, aiming its applications associated with bone regeneration. Cytotoxicity was evaluated in mouse fibroblasts culture cells (NIH3T3) using trypan blue staining. Tissue response was in vivo evaluated by subcutaneous implantation of materials in rats, taking into account the presence of necrosis and connective tissue capsule around implanted materials after 7, 14, 21, 28, 35, 60, and 100 days of surgery. The pattern of inflammation was evaluated by histomorphometry of the inflammatory cells. Chemical and morphological changes of implanted materials after 60 and 100 days were evaluated by Fourier transform infrared (FTIR) absorption spectroscopy and scanning electron microscopy (SEM) images. Cytotoxicity tests indicated a good tolerance of the cells to the biomaterial. The in vivo tissue response of all studied materials showed normal inflammatory pattern, characterized by a reduction of polymorphonuclear leukocytes and an increase in mononuclear leukocytes over the time (p < 0.05 Kruskal-Wallis). On day 60, microscopic analysis showed regression of the chronic inflammatory process around all materials. FTIR showed no changes in chemical composition of materials due to implantation, whereas SEM demonstrated the delivery of starch in the medium. Therefore, the results of the tests performed in vitro and in vivo show that the innovative blends can further be used as biomaterials. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 1284-1293, 2013.
引用
收藏
页码:1284 / 1293
页数:10
相关论文
共 47 条
[1]  
[Anonymous], 1099322006 ISO
[2]  
[Anonymous], 1973, J BIOMECH, V6, P69
[3]  
[Anonymous], ISO 10993-1:2009-Biological Evaluation of Medical Devices- Evaluation and testing within a risk management proces
[4]  
Balabanian Claudia A C A, 2006, J Oral Sci, V48, P201, DOI 10.2334/josnusd.48.201
[5]   ILIAC CREST BONE-GRAFT HARVEST DONOR SITE MORBIDITY - A STATISTICAL EVALUATION [J].
BANWART, JC ;
ASHER, MA ;
HASSANEIN, RS .
SPINE, 1995, 20 (09) :1055-1060
[6]   In vitro biocompatibility of a novel membrane of the composite poly(vinylidene-trifluoroethylene)/barium titanate [J].
Beloti, Marcio M. ;
de Oliveira, Paulo T. ;
Gimenes, Rossano ;
Zaghete, Maria A. ;
Bertolini, Marcio J. ;
Rosa, Adalberto L. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 79A (02) :282-288
[7]   Autologous bone versus calcium-phosphate ceramics in treatment of experimental bone defects [J].
Bloemers, FW ;
Blokhuis, TJ ;
Patka, P ;
Bakker, FC ;
Wippermann, BW ;
Haarman, HJTM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 66B (02) :526-531
[8]   Vascular endothelial cell responses to different electrically charged poly(vinylidene fluoride) supports under static and oscillating flow conditions [J].
Bouaziz, A ;
Richert, A ;
Caprani, A .
BIOMATERIALS, 1997, 18 (02) :107-112
[9]  
Callegari Bianca, 2004, Acta ortop. bras., V12, P160
[10]   Comparison of different test models for the assessment of cytotoxicity of composite resins [J].
Cao, T ;
Saw, TY ;
Heng, BC ;
Liu, H ;
Yap, AUJ ;
Ng, ML .
JOURNAL OF APPLIED TOXICOLOGY, 2005, 25 (02) :101-108