Detection of trace levels of Pb2+ in tap water at boron-doped diamond electrodes with anodic stripping voltammetry

被引:93
作者
Dragoe, D
Spataru, N
Kawasaki, R
Manivannan, A
Spataru, T
Tryk, DA
Fujishima, A
机构
[1] Romanian Acad, Inst Phys Chem, Bucharest 060021, Romania
[2] Univ Tokyo, Sch English, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[3] W Virginia Univ, Dept Phys, Morgantown, WV 26505 USA
[4] Univ Puerto Rico, Dept Chem, San Juan, PR 00931 USA
[5] Kanagawa Acad Sci & Technol, Takatsu Ku, Kanagawa 2130012, Japan
关键词
boron-doped diamond; lead detection; anodic stripping voltammetry;
D O I
10.1016/j.electacta.2005.07.022
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Boron-doped diamond (BDD) electrodes were used to investigate the possibility of detecting trace levels of lead by linear-sweep anodic stripping voltammetry. The low limit of detection (2 nM) is an advantage compared to other electrode materials, and it was found that at low pH values, copper concentrations that are usually present in drinking water do not affect to a large extent the detection of lead. These findings recommend anodic stripping voltammetry at the BDD electrodes as a suitable mercury-free method for the determination of trace levels of lead in drinking water. The results obtained for the lead detection in tap water real samples are in excellent agreement with those found by inductively coupled plasma-mass spectrometry (ICP-MS), demonstrating the practical analytical utility of the method. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2437 / 2441
页数:5
相关论文