Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing

被引:30
|
作者
Lima-Oliveira, Gabriel [1 ,2 ,3 ,4 ]
Lippi, Giuseppe [5 ]
Salvagno, Gian Luca [1 ]
Montagnana, Martina [1 ]
Picheth, Geraldo [2 ]
Guidi, Gian Cesare [1 ,2 ]
机构
[1] Univ Verona, Lab Clin Biochem, Dept Life & Reprod Sci, I-37100 Verona, Italy
[2] Univ Fed Parana, Dept Med Pathol, Postgrad Program Pharmaceut Sci, BR-80060000 Curitiba, Parana, Brazil
[3] MERCOSUL Sect Comm Clin Anal & Vitro Diagnost CSM, Rio De Janeiro, Brazil
[4] Brazilian Soc Clin Anal Sao Paulo State, Sao Paulo, Brazil
[5] Acad Hosp Parma, Dept Pathol & Lab Med, Clin Chem & Hematol Lab, Parma, Italy
关键词
blood collection; plasma samples; preanalytical variability; vacuum tubes; validation process; BIOLOGICAL VARIATION; CLINICAL-CHEMISTRY; QUALITY; COLLECTION; STASIS;
D O I
10.1097/MBC.0b013e32835b72ea
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sometimes in-vitro diagnostic devices (e. g. blood collection tubes) are not validated before use or when the producer's brand is changed. The aim of this study was to validate five brands of sodium citrate vacuum tubes. Blood specimens from 50 volunteers were collected in five different tube brands (I: Venosafe, II: VACUETTE, III: BD Vacutainer, IV: LABOR IMPORT and V: S-Monovette). Routine coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen (FIB)] were performed on ACL TOP instrument using HemosIL reagents. The significance of the differences between samples was assessed by paired Student's t-test, set at P<0.005. Significant differences were observed for: PT when comparing I vs. II, I vs. III, I vs. V, II vs. III, II vs. IV, II vs. V, III vs. IV, III vs. V and IV vs. V; aPTT when comparing I vs. II, I vs. III, I vs. IV, II vs. IV, III vs. IV and IV vs. V. No differences were observed among brands for FIB determination. We suggest that every laboratory management should both standardize the procedures and frequently evaluate the quality of in-vitro diagnostic devices. Blood Coagul Fibrinolysis 24:252-255 (C) 2013 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 10 条
  • [1] Preanalytical management: serum vacuum tubes validation for routine clinical chemistry
    Lima-Oliveira, Gabriel
    Lippi, Giuseppe
    Salvagno, Gian Luca
    Montagnana, Martina
    Picheth, Geraldo
    Guidi, Gian Cesare
    BIOCHEMIA MEDICA, 2012, 22 (02) : 180 - 186
  • [2] Comparison of Low Voleme and Conventional Sodium Citrate Tubes for Routine Coagulation Testing
    Chang, Soon Hee
    CLINICAL LABORATORY, 2021, 67 (07) : 1555 - 1560
  • [3] Guidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing
    Gosselin, Robert C.
    Bowyer, Annette
    Favaloro, Emmanuel J.
    Johnsen, Jill M.
    Lippi, Giuseppe
    Marlar, Richard A.
    Neeves, Keith
    Rollins-Raval, Marian A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2021, 19 (11) : 2857 - 2861
  • [4] Filling accuracy and imprecision of commercial evacuated sodium citrate coagulation tubes
    Lippi, Giuseppe
    Salvagno, Gian Luca
    Biljak, Vanja Radisic
    Kralj, Ana-Katarina
    Kuktic, Ivona
    Gelati, Matteo
    Simundic, Ana-Maria
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2019, 79 (04): : 276 - 279
  • [5] Routine coagulation testing in Vacutainer® Citrate Plus tubes filled at minimum or optimal volume
    Balboni, Fiamma
    Barbui, Stefania
    Gallo, Marco
    Berardi, Margherita
    Vezzosi, Marco
    Lippi, Giuseppe
    DIAGNOSIS, 2020, 7 (01) : 55 - 60
  • [6] Sodium citrate blood contamination by K2-ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing
    Lima-Oliveira, G.
    Salvagno, G. L.
    Danese, E.
    Favaloro, E. J.
    Guidi, G. C.
    Lippi, G.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2015, 37 (03) : 403 - 409
  • [7] Influence of two different buffered sodium citrate concentrations on coagulation testing
    Lippi, G
    Salvagno, GL
    Montagnana, M
    Guidi, GC
    BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 (05) : 381 - 383
  • [8] VALIDATION OF LOW-VOLUME BLOOD COLLECTION TUBES FOR ROUTINE HEMATOLOGIC TESTING
    Lippi, Giuseppe
    Martini, Loredana
    Cortivo, Barbara
    Zecchetto, Chiara
    Ferrari, Anna
    JOURNAL OF MEDICAL BIOCHEMISTRY, 2024, 43 (06) : 955 - 959
  • [9] Management of preanalytical phase for routine hematological testing: is the pneumatic tube system a source of laboratory variability or an important facility tool?
    Lima-Oliveira, G.
    Lippi, G.
    Salvagno, G. L.
    Dima, F.
    Brocco, G.
    Picheth, G.
    Guidi, G. C.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (04) : E37 - E40
  • [10] Brand of dipotassium EDTA vacuum tube as a new source of pre-analytical variability in routine haematology testing
    Lima-Oliveira, G.
    Lippi, G.
    Salvagno, G. L.
    Montagnana, M.
    Poli, G.
    Solero, G. P.
    Picheth, G.
    Guidi, G. C.
    BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 2013, 70 (01) : 6 - 9