Evolution of Nerve Injury with Unexpected EMG Signal Recovery in Thyroid Surgery Using Continuous Intraoperative Neuromonitoring

被引:49
|
作者
Schneider, Rick [1 ,2 ]
Bures, Claudia [3 ]
Lorenz, Kerstin [1 ]
Dralle, Henning [1 ]
Freissmuth, Michael [4 ]
Hermann, Michael [3 ]
机构
[1] Univ Halle Wittenberg, Dept Gen Visceral & Vasc Surg, D-06097 Halle, Germany
[2] Univ Halle Wittenberg, Univ Hosp, Dept Gen Visceral & Vasc Surg, Fac Med, D-06097 Halle, Germany
[3] Kaiserin Elisabeth Spital, Dept Surg, Vienna, Austria
[4] Med Univ Vienna, Ctr Biomol Med & Pharmacol, Inst Pharmacol, Vienna, Austria
关键词
RECURRENT LARYNGEAL NERVE; ANCHOR ELECTRODE;
D O I
10.1007/s00268-012-1853-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Intermittent intraoperative neuromonitoring cannot prevent preparative surgical damage or predict imminent recurrent laryngeal nerve (RLN) damage with subsequent development of loss of electromyogram (EMG) signal during thyroid surgery. In case the nerve is stressed, i.e., from traction near the ligament of Berry, the nerve injury is only detected after it has occurred, not allowing the surgeon to correct the mechanical maneuver and salvage nerve function intraoperatively. The unusual clinical scenario of sacrifice of a tumor-infiltrated RLN was used to study real-time evolution of RLN injury caused by mechanical distention. The ipsilateral vagus nerve (VN) was continuously stimulated with a new stimulation probe, and changes in EMG response were correlated with the varying levels of stretch and traction. Mechanical traction induced an intermittent depression of EMG amplitudes as a sign of impaired propagation of axon potentials or synaptic transmission. Prolonged mechanical stress caused a long-lasting depression of EMG response. When the mechanical distention was relieved, neurotransmission was gradually restored, with reappearance of singular muscle depolarization of full magnitude interspersed between the barely detectable deflections in the EMG recording. These responses of full amplitude appeared with increasing frequency, until the regular continuous EMG pattern was completely restored. Only continuous VN stimulation serves to detect early changes in EMG response that indicate imminent danger to RLN functional integrity and alerts the surgeon to immediately correctable surgical actions, thus possibly preventing nerve damage or transforming damage into a reversible event.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [1] Evolution of Nerve Injury with Unexpected EMG Signal Recovery in Thyroid Surgery Using Continuous Intraoperative Neuromonitoring
    Rick Schneider
    Claudia Bures
    Kerstin Lorenz
    Henning Dralle
    Michael Freissmuth
    Michael Hermann
    World Journal of Surgery, 2013, 37 : 364 - 368
  • [2] Vagus Nerve Injury during Continuous Intraoperative Neuromonitoring (cIONM) for Thyroid Surgery: Assessment of Severity
    Rohaizak, M.
    Faezan, A. R. Nor
    Suraya, O.
    Shahrunniza, A. S.
    IIUM MEDICAL JOURNAL MALAYSIA, 2021, 20 (03): : 110 - 113
  • [3] Continuous Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve during Thyroid Surgery
    Jonas, J.
    ZENTRALBLATT FUR CHIRURGIE, 2010, 135 (03): : 273 - 276
  • [4] Safety of continuous intraoperative vagus nerve neuromonitoring during thyroid surgery
    Mathieson, Timothy
    Jimaja, Wedali
    Triponez, Frederic
    Licker, Marc
    Karenovics, Wolfram
    Makovac, Petra
    Muradbegovic, Mirza
    Belfontali, Valentina
    Bedat, Benoit
    Demarchi, Marco Stefano
    BJS OPEN, 2023, 7 (03):
  • [5] An Evaluation of the Signal Change in the Continuous Neuromonitoring in Thyroid Surgery
    Leinung, S.
    ZENTRALBLATT FUR CHIRURGIE, 2012, 137 (01): : 92 - 92
  • [6] New Backstrap Vagus Electrode for Continuous Intraoperative Neuromonitoring in Thyroid Surgery
    Lamade, Wolfram
    Ulmer, Christoph
    Rieber, Fabian
    Friedrich, Colin
    Koch, Klaus P.
    Thon, Klaus-Peter
    SURGICAL INNOVATION, 2011, 18 (03) : 206 - 213
  • [7] Ultrasound visualization of the vagus nerve for intraoperative neuromonitoring in thyroid surgery
    Hartl, Dana M.
    Bidault, Sophie
    Girard, Elizabeth
    Guerlain, Joanne
    Breuskin, Ingrid
    Lamartina, Livia
    Terroir, Marie
    Leboulleux, Sophie
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 4063 - 4070
  • [8] Continuous intraoperative neuromonitoring for thyroid cancer surgery: A prospective study
    Onoda, Naoyoshi
    Noda, Satoru
    Tauchi, Yukie
    Asano, Yuka
    Kusunoki, Yukina
    Ishihara, Sae
    Morisaki, Tamami
    Kashiwagi, Shinichiro
    Takashima, Tsutomu
    Ohira, Masaichi
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2019, 4 (04): : 455 - 459
  • [9] Thermal injury of the recurrent laryngeal nerve by THUNDERBEAT during thyroid surgery: findings from continuous intraoperative neuromonitoring in a porcine model
    Kwak, Hee Yong
    Dionigi, Gianlorenzo
    Kim, Dasom
    Lee, Hye Yoon
    Son, Gil Soo
    Lee, Jae Bok
    Bae, Jeoung Won
    Kim, Hoon Yub
    JOURNAL OF SURGICAL RESEARCH, 2016, 200 (01) : 177 - 182
  • [10] The learning curve for intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery
    Wojtczak, Beata
    Kaliszewski, Krzysztof
    Sutkowski, Krzysztof
    Glod, Mateusz
    Barczynski, Marcin
    LANGENBECKS ARCHIVES OF SURGERY, 2017, 402 (04) : 701 - 708