Effect of Corrosion Inhibition on the Stress Corrosion Cracking of UNS S31603 Austenitic Stainless Steel

被引:0
作者
Abuzeid, O. A. [1 ]
Aljoboury, A. I. [2 ]
Abou Zour, M. [3 ]
机构
[1] UAE Univ, Dept Mech Engn, POB 17555, Al Ain, U Arab Emirates
[2] Ind Support Serv, Abu Dhabi, U Arab Emirates
[3] Gen Elect, Water Proc Technol ME, Dubai, U Arab Emirates
来源
NEW MATERIALS AND PROCESSES, PTS 1-3 | 2012年 / 476-478卷
关键词
Corrosion inhibition; UNS S31603 Austenitic stainless steel; Stress corrosion cracking; Desalination plants; Molybdate corrosion inhibitor; DESALINATION PLANTS; HYDROCHLORIC-ACID; MOLYBDATE; PUMPS;
D O I
10.4028/www.scientific.net/AMR.476-478.256
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Brine recirculation pumps are essential components used for circulation of brine in multi-stage flashing chambers desalination plants. Failure of these pumps would result in shutdown of the desalination plants. The rotating parts of these pumps (shaft and impeller) are usually made out of stainless steels or Duplex stainless steels. The pressure parts (casings) are usually made out of Ni-resist ductile irons (NDI). In recent years there have been a number of cases in which NDI casing materials failed by stress corrosion cracking (SCC) especially in the Arabian Gulf region. This makes re-evaluation and further studies on the performance of these materials of paramount importance due to process-related economic and reliability considerations. As possible substitutes to NDI casing materials, the authors of this research have recently published material demonstrating the superiority of the SCC resistance of the super DSS, UNS S32750, over the ASS, UNS S31603, in hot brine environment. Economically, the idea of using chemical corrosion inhibitors to enhance the SCC resistance of the ASS, UNS S31603, is appealing, non famous and worth looking at. In this work the effect of corrosion inhibition on the corrosion resistance and SCC of the ASS, UNS S31603, in hot brine environment, is investigated. Brine water was injected with typical treat rate of 350 ppm of passivating type commercially available Molybdate corrosion inhibitor. Theoretically the corrosion inhibitor was proposed to improve the corrosion resistance of ASS, UNS S31603, in brine solution. Electrochemical polarization measurements and SCC tests were used to evaluate the performance of the metal under inhibited and uninhibited environments. Results have shown that treating the brine with this particular type of inhibitor under this particular treat rate and test conditions increased the pitting tendency of the ASS, UNS S31603. Results from both SCC tests and electrochemical measurements are in agreement and both role out the possibility of enhancing corrosion resistance and SCC of ASS UNS S31603 using Molybdate inhibitor.
引用
收藏
页码:256 / +
页数:3
相关论文
共 14 条
[1]   Stress corrosion cracking of stainless steels recommended for building brine recirculation pumps [J].
Aljoboury, A. I. ;
Mourad, A. -H. I. ;
Alawar, A. ;
Abou Zour, M. ;
Abuzeid, O. A. .
ENGINEERING FAILURE ANALYSIS, 2010, 17 (06) :1337-1344
[2]   A study on the failure of pump casings made of ductile Ni-resist cast irons used in desalination plants [J].
Alzafin, Y. A. ;
Mourad, A.-H. I. ;
Abou Zour, M. ;
Abuzeid, O. A. .
ENGINEERING FAILURE ANALYSIS, 2007, 14 (07) :1294-1300
[3]   Stress corrosion cracking of Ni-resist ductile iron used in manufacturing brine circulating pumps of desalination plants [J].
Alzafin, Y. A. ;
Mourad, A. -H. I. ;
Abou Zour, M. ;
Abuzeid, O. A. .
ENGINEERING FAILURE ANALYSIS, 2009, 16 (03) :733-739
[4]  
[Anonymous], 2007, MILL TEST REP
[5]  
[Anonymous], 2006, A240 ASTM
[6]  
[Anonymous], 1996, TM0177 ANSINACE
[7]  
[Anonymous], 2007, MET TEST REP
[8]  
[Anonymous], 2003, A439 ASTM
[9]  
[Anonymous], 1986, 3468 BS
[10]  
[Anonymous], 1993, CORROSION INHIBITORS