Real-time radiative divertor feedback control development for the NSTX-U tokamak using a vacuum ultraviolet spectrometer

被引:5
作者
Soukhanovskii, V. A. [1 ]
Kaita, R. [2 ]
Stratton, B. [2 ]
机构
[1] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA
[2] Princeton Plasma Phys Lab, 100 Stellarator Rd, Princeton, NJ 08543 USA
关键词
PARTICLE CONTROL; DIII-D; PLASMA; DETACHMENT; JT-60U; POWER;
D O I
10.1063/1.4960058
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature T-e estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the Delta n = 0,1 line intensity ratios of carbon, nitrogen, or neon ion lines in the spectral range 300-1600 angstrom. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time T-e-dependent signal within a characteristic divertor detachment equilibration time of similar to 10-15 ms is expected. Published by AIP Publishing.
引用
收藏
页数:4
相关论文
共 27 条
[1]   LABORATORY STUDIES OF UV EMISSIONS OF H-2 BY ELECTRON-IMPACT - THE WERNER-BAND AND LYMAN-BAND SYSTEMS [J].
AJELLO, JM ;
SRIVASTAVA, SK ;
YUNG, YL .
PHYSICAL REVIEW A, 1982, 25 (05) :2485-2498
[2]   Feedback control on edge plasma parameters with ergodic divertor in Tore Supra [J].
Bucalossi, J ;
Gunn, JP ;
Géraud, A ;
Ghendrih, P ;
Grisolia, C ;
Grosman, A ;
Martin, G ;
Moulin, D ;
Pascal, JY .
JOURNAL OF NUCLEAR MATERIALS, 2001, 290 :566-570
[3]   Comprehensive 2D measurements of radiative divertor plasmas in DIII-D [J].
Fenstermacher, ME ;
Wood, RD ;
Allen, SL ;
Brooks, NH ;
Buchenauer, DA ;
Carlstrom, TN ;
Cuthbertson, JW ;
Doyle, EJ ;
Evans, TE ;
Garbet, PM ;
Harvey, RW ;
Hill, DN ;
Hyatt, AW ;
Isler, RC ;
Jackson, G ;
James, RA ;
Jong, R ;
Klepper, CC ;
Lasnier, CJ ;
Leonard, AW ;
Mahdavi, MA ;
Maingi, R ;
Meyer, WH ;
Moyer, RA ;
Nilson, DG ;
Petrie, TW ;
Porter, GD ;
Rhodes, TL ;
Schaffer, MJ ;
Stambaugh, RD ;
Thomas, DM ;
Tugarinov, S ;
Wade, MR ;
Watkins, JG ;
West, WP ;
Whyte, DG .
JOURNAL OF NUCLEAR MATERIALS, 1997, 241 :666-671
[4]   MULTICHANNEL GRAZING-INCIDENCE SPECTROMETER FOR PLASMA IMPURITY DIAGNOSIS - SPRED [J].
FONCK, RJ ;
RAMSEY, AT ;
YELLE, RV .
APPLIED OPTICS, 1982, 21 (12) :2115-2123
[5]   Dependence of divertor heat flux widths on heating power, flux expansion, and plasma current in the NSTX [J].
Gray, T. K. ;
Maingi, R. ;
Soukhanovskii, V. A. ;
Surany, J. E. ;
Ahn, J-W ;
McLean, A. G. .
JOURNAL OF NUCLEAR MATERIALS, 2011, 415 (01) :S360-S364
[6]   Impurity feedback control for enhanced divertor and edge radiation in DIII-D discharges [J].
Jackson, GL ;
Staebler, GM ;
Allen, SL ;
Brooks, NH ;
Evans, TE ;
Ferron, JR ;
Leonard, AW ;
Maingi, R ;
Petrie, TW ;
Schaffer, MJ ;
Wood, RD ;
West, WP ;
Whyte, DG .
JOURNAL OF NUCLEAR MATERIALS, 1997, 241 :618-622
[7]   Divertor power load feedback with nitrogen seeding in ASDEX Upgrade [J].
Kallenbach, A. ;
Dux, R. ;
Fuchs, J. C. ;
Fischer, R. ;
Geiger, B. ;
Giannone, L. ;
Herrmann, A. ;
Lunt, T. ;
Mertens, V. ;
McDermott, R. ;
Neu, R. ;
Puetterich, T. ;
Rathgeber, S. ;
Rohde, V. ;
Schmid, K. ;
Schweinzer, J. ;
Treutterer, W. .
PLASMA PHYSICS AND CONTROLLED FUSION, 2010, 52 (05)
[8]   An analysis of VUV C IV emission from the JET divertor giving measurements of electron temperatures [J].
Lawson, K. D. ;
Aggarwal, K. M. ;
Coffey, I. H. ;
Keenan, F. P. ;
O'Mullane, M. G. ;
Ryc, L. ;
Zacks, J. .
PLASMA PHYSICS AND CONTROLLED FUSION, 2011, 53 (01)
[9]   An absolute sensitivity calibration of the JET VUV SPRED spectrometer [J].
Lawson, K. D. ;
Coffey, I. H. ;
Zacks, J. ;
Stamp, M. F. .
JOURNAL OF INSTRUMENTATION, 2009, 4
[10]   Modification and control of divertor detachment in Alcator C-Mod [J].
Lipschultz, B ;
Goetz, JA ;
LaBombard, B ;
McCracken, GM ;
Ohkawa, H ;
Takase, Y ;
Terry, JL .
JOURNAL OF NUCLEAR MATERIALS, 1997, 241 :771-776