Fabrication of superconducting quantum interference device magnetometers on a glass epoxy polyimide resin substrate with copper terminals

被引:1
作者
Kawai, Jun [1 ]
Kawabata, Miki [1 ]
Oyama, Daisuke [1 ]
Uehara, Gen [1 ]
机构
[1] Kanazasa Inst Technol, Appl Elect Lab, Kanazawa, Ishikawa 9201331, Japan
来源
SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011 | 2012年 / 36卷
关键词
SQUID; Nb/AlAlOx/Nb; fabrication; process; glass-epoxy polyimide resin; thermal change; SYSTEM;
D O I
10.1016/j.phpro.2012.06.157
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
We have developed fabrication technique of superconducting quantum interference device (SQUID) magnetometers based on Nb/AlAlOx/Nb junctions directly on a glass epoxy polyimide resin substrate, which has copper terminals embedded in advance. The advantage of this method is that no additional substrate and wirebonds are needed for assembly. Compared to conventional SQUID magnetometers, which are assembled with a SQUID chip fabricated on a Si substrate and wirebonding technique, low risk of disconnection can be expected. A directly-coupled multi-loop SQUID magnetometer fabricated with this method has as good noise performance as a SQUID magnetometer with the same design fabricated on a Si wafer. The magnetometer sustained its performance through thermal cycle test 13 times so far. (C) 2012 Published by Elsevier B.V. Selection and/or peer-review under responsibility of the Guest Editors.
引用
收藏
页码:262 / 267
页数:6
相关论文
共 9 条
[1]  
DRUNG D, 1990, IEEE T APPL SUPERCON, V57, P406
[2]   SQUID-Based Low Field MRI System for Small Animals [J].
Hatta, Junichi ;
Miyamoto, Masakazu ;
Adachi, Yoshiaki ;
Kawai, Jun ;
Uehara, Gen ;
Kado, Hisashi .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) :526-529
[3]  
Higuchi M., ADV BIOMAGNETISM
[4]   Magnetoencephalogram systems developed at KIT [J].
Kado, H ;
Higuchi, M ;
Shimogawara, M ;
Haruta, Y ;
Adachi, Y ;
Kawai, J ;
Ogata, H ;
Uehara, G .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) :4057-4062
[5]   Superconducting Pickup Coils Fabricated On A Glass Epoxy Polyimide Resin Substrate For SQUID Magnetometers [J].
Kawai, J. ;
Shimozu, T. ;
Kawabata, M. ;
Uehara, G. ;
Kado, H. .
8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97
[6]  
Kawaia J, 2007, INT C SER, V1300, P570
[7]   64-channel magnetocardiogram system based on double relaxation oscillation SQUID planar gradiometers [J].
Lee, Yong-Ho ;
Kim, Jin-Mok ;
Kim, Kiwoong ;
Kwon, Hyukchan ;
yu, Kwon-K Yu ;
Kim, In-Seon ;
Park, Yong-Ki .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2006, 19 (05) :S284-S288
[8]   Development of SQUID-based system for nondestructive evaluation [J].
Nagendran, R. ;
Janawadkar, A. P. ;
Pattabiraman, A. ;
Baisnab, Dipak Kumar ;
Jayapandian, J. ;
Baskaran, R. ;
Vaidhyanathan, L. S. ;
Hariharan, Y. ;
Nagesha, A. ;
Valsan, A. ;
Rao, K. Bhanu Sankara ;
Raj, Baldev .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (03) :3824-3829
[9]   INTRINSIC STRESS OF MAGNETRON-SPUTTERED NIOBIUM FILMS [J].
WU, CT .
THIN SOLID FILMS, 1979, 64 (01) :103-110