Introduction: Microwave and water bath postpolymerization have been suggested as methods to improve the mechanical properties of heat and autopolymerizing acrylic resins. However, the effects of autoclave heating on the fracture properties of autopolymerizing acrylic resins have not been investigated. Purpose: The aim of this study was to assess the effectiveness of various autoclave postpolymerization methods on the fracture properties of 3 different autopolymerizing acrylic resins. Methods: Forty-two specimens of 3 different autopolymerizing acrylic resins (Orthocryl, Paladent RR and Futurajet) were fabricated (40x8x4mm), and each group was further divided into 6 subgroups (n=7). Control group specimens remained as processed (Group 1). The first test group was postpolymerized in a cassette autoclave at 135 degrees C for 6 minutes and the other groups were postpolymerized in a conventional autoclave at 130 degrees C using different time settings (5, 10, 20 or 30 minutes). Fracture toughness was then measured with a three-point bending test. Data were analyzed by ANOVA followed by the Duncan test (alpha=0.05). Results: The fracture toughness of Orthocryl and Paladent-RR acrylic resins significantly increased following conventional autoclave postpolymerization at 130 degrees C for 10 minutes (P<.05). However, the fracture toughness of autoclave postpolymerized Futurajet was not significantly different than its control specimens (P<.05). The fracture toughness of Futurajet was significantly less than Paladent RR and Orthocryl specimens when autoclaved at 130 degrees C for 10 minutes. Conclusions: Within the limitations of this study, it can be suggested that autoclave postpolymerization is an effective method for increasing the fracture toughness of tested autoploymerized acrylic resins.
机构:
Univ Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, Italy
Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, ItalyUniv Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, Italy
Traini, Tonino
Gherlone, Enrico
论文数: 0引用数: 0
h-index: 0
机构:
Univ Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, ItalyUniv Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, Italy
Gherlone, Enrico
Parabita, Stefano Ferrari
论文数: 0引用数: 0
h-index: 0
机构:
Univ Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, ItalyUniv Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, Italy
Parabita, Stefano Ferrari
Caputi, Sergio
论文数: 0引用数: 0
h-index: 0
机构:
Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, ItalyUniv Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, Italy
Caputi, Sergio
Piattelli, Adriano
论文数: 0引用数: 0
h-index: 0
机构:
Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, ItalyUniv Vita Salute San Raffaele, Hosp San Raffaele, Dept Dent, I-20132 Milan, Italy
机构:
Universidade Veiga de Almeida, TijucaUniversidade Veiga de Almeida, Tijuca
Universidade Veiga de Almeida, Tijuca, Brazil
不详
论文数: 0引用数: 0
h-index: 0
机构:
Programa de Engenharia Metalurgica e de Materiais - PEMM, COPPE, Universidade Federal do Rio de Janeiro -UFRJ, 21941-972 Rio de Janeiro - RJ, Bloco FUniversidade Veiga de Almeida, Tijuca
不详
不详
论文数: 0引用数: 0
h-index: 0
机构:
Universidade Federal do Rio de Janiero - IF/UFRJ, Rio de JaneiroUniversidade Veiga de Almeida, Tijuca