Effect of autoclave postpolymerization treatments on the fracture toughness of autopolymerizing dental acrylic resins

被引:0
作者
Durkan, Rukiye [2 ]
Gurbuz, Ayhan [3 ]
Yilmaz, Burak [1 ]
Ozel, M. Birol [4 ]
Bagis, Bora [2 ]
机构
[1] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[2] Karadeniz Tech Univ, Dept Prosthodont, Fac Dent, Trabzon, Turkey
[3] Ankara Univ, Dept Prosthodont, Fac Dent, TR-06100 Ankara, Turkey
[4] Karadeniz Tech Univ, Dept Orthodont, Fac Dent, Trabzon, Turkey
关键词
Acrylic resin; Autoclave; Fracture toughness; RESIDUAL MONOMER CONTENT; DENTURE BASE MATERIALS; MECHANICAL-PROPERTIES; MICROWAVE IRRADIATION; FLEXURAL STRENGTH; WATER; POLYMERIZATION; RELINE; MICROHARDNESS; SOLUBILITY;
D O I
10.5301/JABB.2012.9026
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Introduction: Microwave and water bath postpolymerization have been suggested as methods to improve the mechanical properties of heat and autopolymerizing acrylic resins. However, the effects of autoclave heating on the fracture properties of autopolymerizing acrylic resins have not been investigated. Purpose: The aim of this study was to assess the effectiveness of various autoclave postpolymerization methods on the fracture properties of 3 different autopolymerizing acrylic resins. Methods: Forty-two specimens of 3 different autopolymerizing acrylic resins (Orthocryl, Paladent RR and Futurajet) were fabricated (40x8x4mm), and each group was further divided into 6 subgroups (n=7). Control group specimens remained as processed (Group 1). The first test group was postpolymerized in a cassette autoclave at 135 degrees C for 6 minutes and the other groups were postpolymerized in a conventional autoclave at 130 degrees C using different time settings (5, 10, 20 or 30 minutes). Fracture toughness was then measured with a three-point bending test. Data were analyzed by ANOVA followed by the Duncan test (alpha=0.05). Results: The fracture toughness of Orthocryl and Paladent-RR acrylic resins significantly increased following conventional autoclave postpolymerization at 130 degrees C for 10 minutes (P<.05). However, the fracture toughness of autoclave postpolymerized Futurajet was not significantly different than its control specimens (P<.05). The fracture toughness of Futurajet was significantly less than Paladent RR and Orthocryl specimens when autoclaved at 130 degrees C for 10 minutes. Conclusions: Within the limitations of this study, it can be suggested that autoclave postpolymerization is an effective method for increasing the fracture toughness of tested autoploymerized acrylic resins.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 29 条
[1]  
Anusavice KJ, 2003, PHILLIPS SCI DENT, P33
[2]   The effects of cross-linking agents on the water sorption and solubility characteristics of denture base resin [J].
Arima, T ;
Murata, H ;
Hamada, T .
JOURNAL OF ORAL REHABILITATION, 1996, 23 (07) :476-480
[3]   The effect of post-cure heating on residual, unreacted monomer in a commercial resin composite [J].
Bagis, YH ;
Rueggeberg, FA .
DENTAL MATERIALS, 2000, 16 (04) :244-247
[4]   Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins [J].
Bayraktar, G ;
Guvener, B ;
Bural, C ;
Uresin, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 76B (02) :340-345
[5]   Microwave polymerization of denture base materials. A comparative study [J].
Blagojevic, V ;
Murphy, VM .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (10) :804-808
[6]   ANNEALING AS A MECHANISM OF INCREASING WEAR-RESISTANCE OF COMPOSITES [J].
DEGEE, AJ ;
PALLAV, P ;
WERNER, A ;
DAVIDSON, CL .
DENTAL MATERIALS, 1990, 6 (04) :266-270
[7]   THE EFFECT OF PREPARATION CONDITIONS OF ACRYLIC DENTURE BASE MATERIALS ON THE LEVEL OF RESIDUAL MONOMER, MECHANICAL-PROPERTIES AND WATER-ABSORPTION [J].
DOGAN, A ;
BEK, B ;
CEVIK, NN ;
USANMAZ, A .
JOURNAL OF DENTISTRY, 1995, 23 (05) :313-318
[8]   DEGREE OF DOUBLE-BOND CONVERSION IN LIGHT-CURED COMPOSITES [J].
ELIADES, GC ;
VOUGIOUKLAKIS, GJ ;
CAPUTO, AA .
DENTAL MATERIALS, 1987, 3 (01) :19-25
[9]   Acrylic removable appliances:: Comparative evaluation of different postpolymerization methods [J].
Faltermeier, Andreas ;
Rosentritt, Martin ;
Muessig, Dieter .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (03) :301.e16-301.e22
[10]  
Fujii K, 1989, Dent Mater J, V8, P243