Development and Validation of an Associative Model for the Detection of Glaucoma Using Pupillography

被引:27
作者
Chang, Dolly S. [1 ,2 ,3 ]
Arora, Karun S. [1 ]
Boland, Michael V. [1 ,4 ]
Supakontanasan, Wasu [5 ]
Friedman, David. S. [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ, Wilmer Eye Inst, Glaucoma Ctr Excellence, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Wilmer Eye Inst, Dana Ctr Prevent Ophthalmol, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Baltimore, MD USA
[4] Johns Hopkins Univ, Sch Med, Div Hlth Sci Informat, Baltimore, MD USA
[5] Mahidol Univ, Ramathibodi Hosp, Dept Ophthalmol, Bangkok 10700, Thailand
关键词
AFFERENT PUPILLARY DEFECT; OPEN-ANGLE GLAUCOMA; MACULAR DEGENERATION; PERIMETRY; DAMAGE; STIMULATION;
D O I
10.1016/j.ajo.2013.07.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To develop and validate an associative model using pupillography that best discriminates those with and without glaucoma. DESIGN: A prospective case-control study. METHODS: We enrolled 148 patients with glaucoma (mean age 67 +/- 11) and 71 controls (mean age 60 +/- 10) in a clinical setting. This prototype pupillometer is designed to record and analyze pupillary responses at multiple, controlled stimulus intensities while using varied stimulus patterns and colors. We evaluated three approaches: (1) comparing the responses between the two eyes; (2) comparing responses to stimuli between the superonasal and inferonasal fields within each eye; and (3) calculating the absolute pupil response of each individual eye. Associative models were developed using stepwise regression or forward selection with Akaike information criterion and validated by fivefold cross-validation. We assessed the associative model using sensitivity, specificity and the area-under-the-receiver operating characteristic curve. RESULTS: Persons with glaucoma had more asymmetric pupil responses in the two eyes (P < 0.001); between superonasal and inferonasal visual field within the same eye (P = 0.014); and smaller amplitudes, slower velocities and longer latencies of pupil responses compared to controls (all P < 0.001). A model including age and these three components resulted in an area-under-thereceiver operating characteristic curve of 0.87 (95% CI 0.83 to 0.92) with 80% sensitivity and specificity in detecting glaucoma. This result remained robust after cross-validation. CONCLUSIONS: Using pupillography, we were able to discriminate among persons with glaucoma and those with normal eye examinations. With refinement, pupil testing may provide a simple approach for glaucoma screening. (C) 2013 by Elsevier Inc. All rights reserved.
引用
收藏
页码:1285 / 1296
页数:12
相关论文
共 37 条
  • [1] [Anonymous], 2004, ARCH OPHTHALMOL-CHIC, V122, P532
  • [2] GLAUCOMA HEMIFIELD TEST - AUTOMATED VISUAL-FIELD EVALUATION[J]. ASMAN, P;HEIJL, A. ARCHIVES OF OPHTHALMOLOGY, 1992(06)
  • [3] Dichoptic Multifocal Pupillography Reveals Afferent Visual Field Defects in Early Type 2 Diabetes[J]. Bell, Andrew;James, Andrew C.;Kolic, Maria;Essex, Rohan W.;Maddess, Ted. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010(01)
  • [4] Estimating the rate of progressive visual field damage in those with open-angle glaucoma, from cross-sectional data[J]. Broman, Aimee Teo;Quigley, Harry A.;West, Sheila K.;Katz, Joanne;Munoz, Beatriz;Bandeen-Roche, Karen;Tielsch, James M.;Friedman, David S.;Crowston, Jonathan;Taylor, Hugh R.;Varma, Rohit;Leske, M. Cristina;Bengtsson, Boel;Heijl, Anders;He, Mingguang;Foster, Paul J. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008(01)
  • [5] The clinical effectiveness and cost-effectiveness of screening for open angle glaucoma: a systematic review and economic evaluation[J]. Burr, Jm;Mowatt, G.;Hernandez, R.;Siddiqui, Mar;Cook, J.;Lourenco, T.;Ramsay, C.;Vale, L.;Fraser, C.;Azuara-Blanco, A.;Deeks, J.;Cairns, J.;Wormald, R.;McPherson, S.;Rabindranath, K.;Grant, A. HEALTH TECHNOLOGY ASSESSMENT, 2007(41)
  • [6] Chauhan BC, 1999, INVEST OPHTH VIS SCI, V40, P648
  • [7] Rapid pupil-based assessment of glaucomatous damage[J]. Chen, Yanjun;Wyatt, Harry J.;Swanson, William H.;Dul, Mitchell W. OPTOMETRY AND VISION SCIENCE, 2008(06)
  • [8] Ervin A-M., 2012, SCREENING GLAUCOMA C
  • [9] ASSESSMENT OF UNILATERAL AFFERENT PUPILLARY DEFECTS BY PUPILLOGRAPHY[J]. FISON, PN;GARLICK, DJ;SMITH, SE. BRITISH JOURNAL OF OPHTHALMOLOGY, 1979(03)
  • [10] HASHIMOTO E, 1991, Nippon Ganka Gakkai Zasshi, V95, P265