Multipole correction of stretched-wire measurements of field-gradients in quadrupole accelerator magnets

被引:9
作者
Arpaia, P. [1 ]
Buzio, M. [2 ]
Petrone, C. [1 ,2 ]
Russenschuck, S. [2 ]
Walckiers, L. [2 ]
机构
[1] Univ Sannio, Dept Engn, I-82100 Benevento, Italy
[2] CERN, Dept Technol, Grp Magnets Superconductors & Cryostats MSC, Sect Magnet Measurements, CH-1211 Geneva 23, Switzerland
关键词
Instrumentation for particle accelerators and storage rings - high energy (linear accelerators; synchrotrons); Hardware and accelerator control systems; Acceleration cavities and magnets superconducting (high-temperature superconductor; radiation hardened magnets; normal-conducting; permanent magnet devices; wigglers and undulators); Beam-line instrumentation (beam position and profile monitors; beam-intensity monitors; bunch length monitors);
D O I
10.1088/1748-0221/8/08/P08010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A correction of field gradients in quadrupole accelerator magnets measured by stretched-wire methods is described. The gradient is first measured by means of the single-stretched-wire method. By using the same experimental setup, the relative multipole-field errors of the quadrupole are then measured by means of the oscillating-wire technique and used for the correction scheme. Results of the experimental validation are presented for a prototype quadrupole for the CLIC accelerator study at CERN.
引用
收藏
页数:11
相关论文
共 15 条
[1]   Measuring field multipoles in accelerator magnets with small-apertures by an oscillating wire moved on a circular trajectory [J].
Arpaia, P. ;
Buzio, M. ;
Perez, J. Garcia ;
Petrone, C. ;
Russenschuck, S. ;
Walckiers, L. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[2]  
Arpaia P., 2012, IMEKO WORLD C METR G
[3]  
Arpaia P., 2011, CERNATS2011188
[4]   A software framework for developing measurement applications under variable requirements [J].
Arpaia, Pasquale ;
Buzio, Marco ;
Fiscarelli, Lucio ;
Inglese, Vitaliano .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (11)
[5]   Characterization and tuning of ultrahigh gradient permanent magnet quadrupoles [J].
Becker, S. ;
Bussmann, M. ;
Raith, S. ;
Fuchs, M. ;
Weingartner, R. ;
Kunz, P. ;
Lauth, W. ;
Schramm, U. ;
El Ghazaly, M. ;
Gruener, F. ;
Backe, H. ;
Habs, D. .
PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2009, 12 (10)
[6]   Twin rotating coils for cold magnetic measurements of 15 m long LHC dipoles [J].
Billan, J ;
Bottura, L ;
Buzio, M ;
D'Angelo, G ;
Deferne, G ;
Dunkel, O ;
Legrand, P ;
Rijllart, A ;
Siemko, A ;
Sievers, P ;
Schloss, S ;
Walckiers, L .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) :1422-1426
[7]   Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility [J].
Dabrowski, A. E. ;
Bettoni, S. ;
Bravin, E. ;
Corsini, R. ;
Doebert, S. ;
Lefevre, T. ;
Rabiller, A. ;
Soby, L. ;
Skowronski, P. K. ;
Tecker, F. ;
Egger, D. ;
Ferrari, A. ;
Welsch, C. P. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[8]  
Deferne G., 2005, IMMW INT MAGN MEAS W
[9]  
Deferne G., 2003, 13 INT MAGN MEAS WOR
[10]   Field alignment of quadrupole magnets for the LHC interaction regions [J].
DiMarco, J ;
Glass, H ;
Lamm, MJ ;
Schlabach, P ;
Sylvester, C ;
Tompkins, JC ;
Krzywinski, J .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) :127-130