Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose

被引:76
作者
Ding, George X. [1 ]
Munro, Peter [2 ]
机构
[1] Vanderbilt Univ, Sch Med, Dept Radiat Oncol, Nashville, TN 37232 USA
[2] iLab GmbH, Varian Med Syst, Baden, Switzerland
关键词
MV imaging dose; kV-radiograph dose; kV-CBCT dose; kV-CBCT in TrueBeam; Imaging dose reduction techniques; CONE-BEAM CT; MONTE-CARLO-SIMULATION; COMPUTED-TOMOGRAPHY; GUIDED RADIOTHERAPY; DOSIMETRY; CBCT; IMRT; IGRT;
D O I
10.1016/j.radonc.2013.05.034
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare imaging doses from MV images, kV radiographs, and kV-CBCT and describe methods to reduce the dose to patient's organs using existing on-board imaging devices. Method and materials: Monte Carlo techniques were used to simulate kV. X-ray sources. The kV image doses to a variety of patient anatomies were calculated by using the simulated realistic sources to deposit dose in patient CT images. For MV imaging, the doses for the same patients were calculated using a commercial treatment planning system. Results: Portal imaging results in the largest dose to anatomic structures, followed by Varian OBI CBCT, Varian TrueBeam CBCT and then kV radiographs. The imaging doses for the 50% volume from the DVHs, D50, to the eyes for representative head images are 4.3-4.8 cGy; 0.05-0.06 cGy; 0.04-0.05 cGy; and, 0.12 cGy; D50 to the bladder for representative pelvis images are 3.3 cGy; 1.6 cGy; 1.0 cGy; and, 0.07 cGy; while D50 to the heart for representative thorax images are 3.5 cGy; 0.42 cGy; 0.2 cGy; and, 0.07 cGy; when using portal imaging, OBI kV-CBCT scans, TrueBeam kV-CBCT scans and kV radiographs, respectively. The orientation of the kV beam can affect organ dose. For example, D50 to the eyes can be reduced from 0.12 cGy using AP and right lateral radiographs to 0.008-0.017 cGy when using PA and right lateral radiographs. In addition, organ exposures can be further reduced to 15-70% of their original values with the use of a full-fan, bow-tie filter for kV radiographs. In contrast, organ doses increase by a factor of similar to 2-4 if bow-tie filters are not used during kV-CBCT acquisitions. Conclusion: Current on-board kV imaging devices result in much lower imaging doses compared to MV imagers even taking into account of higher bone dose from kV X-rays. And a variety of approaches are available to significantly reduce the image doses. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 34 条
[1]  
Andreo PBD., 2000, TECHNICAL REPORT SER, V18, P35
[2]   Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation [J].
Chow, James C. L. ;
Leung, Michael K. K. ;
Islam, Mohammad K. ;
Norrlinger, Bernhard D. ;
Jaffray, David A. .
MEDICAL PHYSICS, 2008, 35 (01) :52-60
[3]   Reduced CBCT Imaging Dose Due to the New X-Ray Source in TrueBeam ™ [J].
Ding, G. ;
Munro, P. .
MEDICAL PHYSICS, 2011, 38 (06)
[4]   Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. .
MEDICAL PHYSICS, 2008, 35 (03) :1135-1144
[5]   Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (06) :1595-1615
[6]   Reducing radiation exposure to patients from kV-CBCT imaging [J].
Ding, George X. ;
Munro, Peter ;
Pawlowski, Jason ;
Malcolm, Arnold ;
Coffey, Charles W. .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) :585-592
[7]   Dosimetric evaluation of the OneDose™ MOSFET for measuring kilovoltage imaging dose from image-guided radiotherapy procedures [J].
Ding, George X. ;
Coffey, Charles W. .
MEDICAL PHYSICS, 2010, 37 (09) :4880-4885
[8]   Beam characteristics and radiation output of a kilovoltage cone-beam CT [J].
Ding, George X. ;
Coffey, Charles W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) :5231-5248
[9]   RADIATION DOSE FROM KILOVOLTAGE CONE BEAM COMPUTED TOMOGRAPHY IN AN IMAGE-GUIDED RADIOTHERAPY PROCEDURE [J].
Ding, George X. ;
Coffey, Charles W. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02) :610-617
[10]   Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit [J].
Downes, P. ;
Jarvis, R. ;
Radu, E. ;
Kawrakow, I. ;
Spezi, E. .
MEDICAL PHYSICS, 2009, 36 (09) :4156-4167