Is greater than 145° of deep knee flexion under weight-bearing conditions safe after total knee arthroplasty? A FLUOROSCOPIC ANALYSIS OF JAPANESE-STYLE DEEP KNEE FLEXION

被引:17
|
作者
Niki, Y. [1 ]
Takeda, Y. [1 ]
Udagawa, K. [1 ]
Enomoto, H. [1 ]
Toyama, Y. [1 ]
Suda, Y. [1 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Shinjuku Ku, Tokyo 1608582, Japan
关键词
POLYETHYLENE TIBIAL POST; IN-VIVO; KINEMATICS; FRACTURE;
D O I
10.1302/0301-620X.95B6.30757
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We investigated the characteristics of patients who achieved Japanese-style deep flexion (seiza-sitting) after total knee replacement (TKR) and measured three-dimensional positioning and the contact positions of the femoral and tibial components. Seiza-sitting was achieved after surgery by 23 patients (29 knees) of a series of 463 TKRs in 341 patients. Pre-operatively most of these patients were capable of seiza-sitting, had a lower body mass index and a favourable attitude towards the Japanese lifestyle (27 of 29 knees). According to two-/three-dimensional image registration analysis in the seiza-sitting position, flexion, varus and internal rotation angles of the tibial component relative to the femoral component had means of 148 (sip 8.0), 1.9 degrees (6D 3.2) and 13.4 degrees (SD 5.9), respectively. Femoral surface contact positions tended to be close to the posterior edge of the tibial polyethylene insert, particularly in the lateral compartment, but only 8.3% (two of 24) of knees showed femoral subluxation over the posterior edge. The mean contact positions of the femoral cam on the tibial post were located 7.8 mm (SD 1.5) proximal to the lowest point of the polyethylene surface and 5.5 mm (6D 0.9) medial to the centre of the post, indicating that the post-cam contact position translated medially during seiza-sitting, but not proximally. Collectively, the seiza-sitting position seems safe against component dislocation, but the risks of posterior edge loading and breakage of the tibial polyethylene post remain.
引用
收藏
页码:782 / 787
页数:6
相关论文
共 41 条
  • [21] Bicruciate-stabilised total knee arthroplasty provides good functional stability during high-flexion weight-bearing activities
    Kenichi Kono
    Hiroshi Inui
    Tetsuya Tomita
    Takaharu Yamazaki
    Shuji Taketomi
    Kazuomi Sugamoto
    Sakae Tanaka
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 2096 - 2103
  • [22] A greater reduction in the distal femoral anterior condyle improves flexion after total knee arthroplasty in patients with osteoarthritis
    Nishitani, Kohei
    Hatada, Ryosuke
    Kuriyama, Shinichi
    Lyman, Stephen L.
    Nakamura, Shinichiro
    Ito, Hiromu
    Matsuda, Shuicih
    KNEE, 2019, 26 (06) : 1364 - 1371
  • [23] Varus alignment after total knee arthroplasty results in greater axial rotation during deep knee bend activity
    Sekiguchi, Kazuya
    Nakamura, Shinichiro
    Nakamura, Kenji
    Ito, Hiromu
    Kuriyama, Shinichi
    Nishitani, Kohei
    Komistek, Richard D.
    Matsuda, Shuichi
    CLINICAL BIOMECHANICS, 2020, 77
  • [24] In vivo kinematics of a newly updated posterior-stabilised mobile-bearing total knee arthroplasty in weight-bearing and non-weight-bearing high-flexion activities
    Kage, Tomofumi
    Inui, Hiroshi
    Tomita, Tetsuya
    Yamazaki, Takaharu
    Taketomi, Shuji
    Yamagami, Ryota
    Kono, Kenichi
    Kawaguchi, Kohei
    Sameshima, Shin
    Tanaka, Sakae
    KNEE, 2021, 29 : 183 - 189
  • [25] In vivo kinematic analysis of a high-flexion posterior stabilized fixed-bearing knee prosthesis in deep knee-bending motion
    Tamaki, Masashi
    Tomita, Tetsuya
    Yamazaki, Takaharu
    Hozack, William J.
    Yoshikawa, Hideki
    Sugamoto, Kazuomi
    JOURNAL OF ARTHROPLASTY, 2008, 23 (06) : 879 - 885
  • [26] Biomechanical evaluation of new total knee arthroplasty (TKA) enabling high deep flexion: Stand-sit-stand motion condition
    Han, Paul
    Jang, Young Woong
    Kim, Jung Sung
    Yoo, Oui Sik
    Lee, Myung Chul
    Lim, Dohyung
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (12) : 2623 - 2629
  • [27] In Vivo Postoperative Motion of Fixed and Mobile Medial Pivot Knees Under Weight-Bearing Conditions after Cruciate-Sacrificing Total Knee Arthroplasty
    Yoshioka, Toru
    Okimoto, Nobukazu
    Sawa, Mikiya
    Asano, Kei
    Obayashi, Kenji
    Kawasaki, Makoto
    Majima, Tokifumi
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2023, 90 (01) : 103 - 110
  • [28] In Vivo Kinematics of Bicruciate-Retaining Total Knee Arthroplasty with Anatomical Articular Surface under High-Flexion Conditions
    Kono, Kenichi
    Inui, Hiroshi
    Tomita, Tetsuya
    Yamazaki, Takaharu
    Taketomi, Shuji
    Tanaka, Sakae
    JOURNAL OF KNEE SURGERY, 2021, 34 (04) : 452 - 459
  • [29] Medial-pivot total knee arthroplasty enhances tibiofemoral axial rotation stability in weight-bearing mid-range flexion compared to posterior-stabilised system
    Yu, Wanxin
    Zou, Diyang
    Tan, Jiaqi
    Zheng, Nan
    Ma, Xin
    Cheng, Rongshan
    Chen, Yunsu
    Tsai, Tsung-Yuan
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (08) : 2075 - 2086
  • [30] Different femorotibial contact on the weight-bearing: midflexion between normal and varus aligned knees after total knee arthroplasty
    Eisaku Fujimoto
    Yoshiaki Sasashige
    Tetsuya Tomita
    Kenji Kashiwagi
    Amiko Inoue
    Mikiya Sawa
    Yuki Ota
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1720 - 1728