Method development for determining the malodor source and pollution in industrial park

被引:21
作者
Mao, I-Fang [2 ,3 ]
Chen, Mei-Ru [1 ,4 ]
Wang, Lee [5 ]
Chen, Mei-Lien [6 ]
Lai, Sin-Chen [4 ]
Tsai, Chung-Jung [1 ,4 ]
机构
[1] Chung Hwa Univ Med Technol, Dept Occupat Safety & Hlth, Tainan, Taiwan
[2] Chung Shan Med Univ, Dept Occupat Safety & Hlth, Taichung, Taiwan
[3] Chung Shan Med Univ Hosp, Dept Med Res, Taichung, Taiwan
[4] Chung Hwa Univ Med Technol, Inst Biosafety, Tainan, Taiwan
[5] Chung Shan Med Univ, Dept Publ Hlth, Taichung, Taiwan
[6] Natl Yang Ming Univ, Inst Environm & Occupat Hlth Sci, Taipei 112, Taiwan
关键词
Malodor; Odor intensity; TVOCs; Industrial park; CHROMATOGRAPHY-MASS-SPECTROMETRY; WATER TREATMENT PLANTS; WASTE-WATER; ORGANIC-COMPOUNDS; ODOR MEASUREMENT; ELECTRONIC NOSE; AIR-POLLUTION; OLFACTOMETRY; OPERATIONS; PERFORMANCE;
D O I
10.1016/j.scitotenv.2012.08.056
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Malodor pollution emitted from industrial park has become an important environmental issue. However, the difficulty in investigating malodor pollution is in determining the malodor source. The objective of this study was to develop a model for determining the malodor source and pollution in industrial park, via multiple time and site measurements of odor intensity and air pollutants, together with wind direction in different seasons, and the critical environmental factors could be also identified by correlating the odor intensities with meteorological conditions and the concentrations of air pollutants. A high-malodor-polluted industrial park involving metal and petrochemistry processing industries was selected as the study subject, and sampling was performed close to residential districts. Nine sites were selected as sampling points by a chessboard design, with each site measured for 5 days in fall and spring, respectively. Odor intensity (ratings 0-5) and environmental factors, including meteorological condition, PM10, PM25, total volatile organic compounds (TVOCs), ammonia and reduced sulfides, were evaluated six times daily. The results indicated that the incidences of odor ratings 1-5 were 71.9% and 81.0% in two seasons in the sampling area, and an open ditch for collecting industrial wastewater for feeding to the wastewater treatment plant was identified as the main odor source. Multiple regression analysis showed that the odor rating significantly correlated with TVOC concentration and wind speed (P < 0.05): odor intensity increased by 0.001 units on the rating scale for each 1 ppb increase in TVOCs, and decreased by 0.154 units for each 1 m/s increase in wind speed. This study developed a method to explore malodor pollution in industrial park, providing a novel thinking to understand and resolve malodor problems. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 2003, EN 13725
[2]  
[Anonymous], 2009, AM J PUBLIC HEALTH, DOI [10.2105/ajph.2008.148924, DOI 10.2105/AJPH.2008.148924, 10.2105/AJPH.2008.148924.]
[3]  
ASTM, 1997, E67991 ASTM
[4]   Residential exposure to outdoor air pollution from livestock operations and perceived annoyance among citizens [J].
Blanes-Vidal, Victoria ;
Suh, Helen ;
Nadimi, Esmaeil S. ;
Lofstrom, Per ;
Ellermann, Thomas ;
Andersen, Helle V. ;
Schwartz, Joel .
ENVIRONMENT INTERNATIONAL, 2012, 40 :44-50
[5]   Odour measurement - Factors affecting olfactometry panel performance [J].
Bliss, PJ ;
Schulz, TJ ;
Senger, T ;
Kaye, RB .
WATER SCIENCE AND TECHNOLOGY, 1996, 34 (3-4) :549-556
[6]   Development of an odor wheel classification scheme for wastewater [J].
Burlingame, GA ;
Suffet, IH ;
Khiari, D ;
Bruchet, AL .
WATER SCIENCE AND TECHNOLOGY, 2004, 49 (09) :201-209
[7]  
Chen HK, 1997, THESIS NATL TAIWAN U
[8]   Gas chromatography-mass spectrometry as a tool for estimating odour concentrations of biofilter effluents at aerobic composting and rendering plants [J].
Defoer, N ;
De Bo, I ;
Van Langenhove, H ;
Dewulf, J ;
Van Elst, T .
JOURNAL OF CHROMATOGRAPHY A, 2002, 970 (1-2) :259-273
[9]  
Devos M., 1990, Standardized Human Olfactory Thresholds
[10]   Odor-causing volatile organic compounds in wastewater treatment plant units and sludge management areas [J].
Dincer, Faruk ;
Muezzinoglu, Aysen .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2008, 43 (13) :1569-1574