Contrast-enhanced ultrasound guided biopsy of superficial toraco-abdominal and neck lesions. Initial experience in 20 patients

被引:0
|
作者
Sparchez, Zeno [1 ]
Radu, Pompilia [1 ]
Kacso, Gabriel [2 ]
Eniu, Dan [2 ]
Hica, Stefan
Sparchez, Mihaela
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Med 3, Inst Gastroenterol & Hepatol, Cluj Napoca, Romania
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Pediat 2, Dept Oncol, Cluj Napoca, Romania
关键词
superficial tumors; contrast-enhanced ultrasound; percutaneous biopsy;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: In the diagnostic workup of superficial located tumors, percutaneous biopsy plays an important role. However, a successful retrieval of an adequate tissue sample is achievable in only 80-90% of the cases, mainly due to tissue inhomogenities. Contrast-enhanced ultrasound (CEUS) was successfully used to optimize the percutaneous biopsy in several tumors. The aim of our study was to assess the feasibility of CEUS as a direct guiding method for percutaneous biopsy of superficial toraco-abdominal and neck tumors. Material and methods: Twenty patients aged 12-75 years with superficial toraco-abdominal and neck masses were studied. CEUS guided biopsy was performed using the contrast harmonic imaging technique with 9 MHz broadband linear transducer (10 cases) or 3.5MHz transducer (10 cases). The needle (18 G Bard coupled on an automatic device Bard Magnum) was directed in arterial phase into the enhanced, perfused areas. The following parameters were recorded: maximal length of the tumor, perfusion pattern, number of passages, length of the specimen, rate of complications. Results: The mean maximal length of the tumor was 6.95 cm (range 4-10.6 cm). CEUS guided biopsy was technical successful in 100% of patients. The mean number of passages needed to sample a good specimen was 1.6, range 1-3. The mean length of the specimen was 1.18 cm, range 0.8-1.4cm. The perfusion patterns of the tumors in our series were: P1-non-enhancing mass-11.1 %, P2 peripherally enhancing mass with non-enhancing central area -5.6%, P3 diffusely enhancing mass with scattered non-enhancing areas -77.7 % and P4 completely homogeneously enhancing masses -5.6% of patients. The sensitivity of CEUS guided biopsy in the diagnosis of superficial tumors was 100%. For adenopathies a sub-typing was possible in all cases. There was only one minor hematoma around the punctured tumor in one patient. Conclusions: In our series 83% of the tumors had a perfusion pattern (P2 and P3) that may lead to sampling errors in case of US guided biopsy. CEUS guided biopsy of toraco-abdominal and neck tumors is a feasible technique that improves the sensitivity of percutaneous biopsy to 100%.
引用
收藏
页码:288 / 293
页数:6
相关论文
共 50 条
  • [41] Clinical performance of Xpert MTB/RIF on contrast-enhanced ultrasound-guided core biopsy specimens for rapid diagnosis of superficial tuberculous lymphadenitis in high TB burden settings
    Sun, Wenwen
    Gu, Jin
    Bi, Ke
    Zhang, Yi
    Shen, Meng-jun
    Wang, Yin
    Fan, Lin
    INFECTION, 2021, 49 (04) : 653 - 660
  • [42] Clinical performance of Xpert MTB/RIF on contrast-enhanced ultrasound-guided core biopsy specimens for rapid diagnosis of superficial tuberculous lymphadenitis in high TB burden settings
    Wenwen Sun
    Jin Gu
    Ke Bi
    Yi Zhang
    Meng-jun Shen
    Yin Wang
    Lin Fan
    Infection, 2021, 49 : 653 - 660
  • [43] Undetermined focal liver lesions on gray-scale ultrasound in patients with fatty liver: Characterization with contrast-enhanced ultrasound
    Wang, Zhi-Li
    Tang, Jie
    Weskott, Hance Peter
    Li, Jun-Lai
    Wang, Wei
    Luo, Yu-Kun
    An, Li-Chun
    Xu, Jian-Hong
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 (10) : 1511 - 1519
  • [44] Blunt abdominal trauma: role of contrast-enhanced ultrasound (CEUS) in the detection and staging of abdominal traumatic lesions compared to US and CE-MDCT
    Sessa, Barbara
    Trinci, Margherita
    Ianniello, Stefania
    Menichini, Guendalina
    Galluzzo, Michele
    Miele, Vittorio
    RADIOLOGIA MEDICA, 2015, 120 (02): : 180 - 189
  • [45] Diagnostic accuracy of contrast-enhanced ultrasound for characterization of kidney lesions in patients with and without chronic kidney disease
    Emily Hueywen Chang
    Wui Kheong Chong
    Sandeep Kumar Kasoji
    Julia Rose Fielding
    Ersan Altun
    Lee B. Mullin
    Jung In Kim
    Jason Peter Fine
    Paul Alexander Dayton
    Wendy Kimryn Rathmell
    BMC Nephrology, 18
  • [46] Contrast-enhanced ultrasound for differentiating benign from malignant focal solid renal lesions in pediatric patients
    Fu, Yusi
    Zhong, Jia
    Tan, Yan
    Zheng, Taiqing
    Liu, Minghui
    Wang, Guotao
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [47] Diagnostic accuracy of contrast-enhanced ultrasound for characterization of kidney lesions in patients with and without chronic kidney disease
    Chang, Emily Hueywen
    Chong, Wui Kheong
    Kasoji, Sandeep Kumar
    Fielding, Julia Rose
    Altun, Ersan
    Mullin, Lee B.
    Kim, Jung In
    Fine, Jason Peter
    Dayton, Paul Alexander
    Rathmell, Wendy Kimryn
    BMC NEPHROLOGY, 2017, 18
  • [48] Contrast-enhanced ultrasound targeted versus conventional ultrasound guided systematic prostate biopsy for the accurate diagnosis of prostate cancer: A meta-analysis
    Zhang, Ming
    Meng, Qingsong
    Feng, Lulu
    Wang, Dongbin
    Qu, Changbao
    Tian, Hui
    Jia, Jianghua
    Gao, Qinglu
    Wang, Xin
    MEDICINE, 2022, 101 (51)
  • [49] Blunt abdominal trauma: role of contrast-enhanced ultrasound (CEUS) in the detection and staging of abdominal traumatic lesions compared to US and CE-MDCT
    Barbara Sessa
    Margherita Trinci
    Stefania Ianniello
    Guendalina Menichini
    Michele Galluzzo
    Vittorio Miele
    La radiologia medica, 2015, 120 : 180 - 189
  • [50] Comparative study of core needle biopsy and fine needle aspiration in the treatment of metastatic lymph nodes guided by contrast-enhanced ultrasound
    Mu, Wei-na
    Li, Jian-heng
    Liu, Ying
    Liang, Hui-qing
    Liu, Xin
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (06) : 1477 - 1482