Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems

被引:45
|
作者
Hintze, H [1 ]
Wenzel, A [1 ]
机构
[1] Aarhus Univ, Royal Dent Coll, Dept Oral Radiol, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
digital radiography; dental; dental caries; diagnostic test; ROC curve;
D O I
10.1038/sj.dmfr.4600645
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the influence of the validation method on the diagnostic accuracy and the relative comparison of eight radiographic systems for caries detection. Methods: Three hundred and thirty-eight approximal and 145 occlusal surfaces were radiographed under standardised conditions using six CCD-based sensor systems: MPDx (Dental/Medical Diagnostic Systems Inc., Woodland Hills, CA, USA), Dixi (Planmeca, Helsinki, Finland), Sidexis (Sirona, Bensheim, Germany), RVG(old) (Trophy, Paris, France, 1994 model), RVG(new) (Trophy, Paris, France, 2000 model) and Visualix (Gendex, Milan, Italy) and two film systems: Ektaspeed Plus and Insight (Eastman Kodak, Rochester, NY, USA). Four observers examined the radiographs for approximal and occlusal caries using a five-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (A(z)). Results: For both approximal and occlusal caries the mean A(z) of the eight radiographic systems was significantly higher using radiographic than histological validation (P<0.001). Using histological validation for approximal caries, Dixi (A(z)=0.71) and Ektaspeed Plus (A(z)=0.7) were not significantly different, but Dixi was significantly more accurate than the other digital systems and the Insight film. Using radiographic validation for approximal caries, Ektaspeed Plus (A(z)=0.87) was significantly more accurate than Dixi (A(z)=0.82). Dixi was significantly more accurate than MPDx (A(z) = 0.74), RVG(old) (A(z) = 0.77), RVG(new) (A(z) = 0.77) and Visualix (A(z)= 0.76). Corresponding variations were found for occlusal caries depending on the validation method. Using histological validation, MPDx (A(z)=0.76) was significantly less accurate than Dixi (A(z)=0.81), Sidexis (A(z)=0.8), Ektaspeed Plus (A(z)=0.82) and Insight (A(z)=0.81). Using radiographic validation, MPDx (A(z)=0.83) was also significantly less accurate than RVG(old) (A(z)= 0.89) and RVG(new) (A(z) = 0.9). Conclusion: A(z) obtained from radiographic validation was significantly higher than A(z) obtained from histological validation. Comparison of the diagnostic efficacy for caries of the eight radiographic systems was strongly influenced by the validation method.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 10 条
  • [1] Diagnostic accuracy of two software modalities for detection of caries lesions in digital radiographs from four dental systems
    Hintze, H
    DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (02) : 78 - 82
  • [2] Comparison of digital systems and conventional dental film for the detection of approximal enamel caries
    Pontual, A. A.
    de Melo, D. P.
    de Almeida, S. M.
    Boscolo, F. N.
    Haiter Neto, F.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (07) : 431 - 436
  • [3] Two- and three-dimensional imaging modalities for the detection of caries.: A comparison between film, digital radiography and tuned aperture computed tomography (TACT™)
    Abreu, M
    Tyndall, DA
    Platin, E
    Ludlow, JB
    Phillips, C
    DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (03) : 152 - 157
  • [4] Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems
    Syriopoulos, K
    Sanderink, GCH
    Velders, XL
    van der Stelt, PF
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (05) : 312 - 318
  • [5] Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries
    Abesi, Farida
    Mirshekar, Alireza
    Moudi, Ehsan
    Seyedmajidi, Maryam
    Haghanifar, Sina
    Haghighat, Nima
    Bijani, Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2012, 9 (01) : 17 - 21
  • [6] Comparison of the Accuracy of Digital Radiography with Conventional Radiography and Visual Examination in the Detection of Permanent Teeth Interproximal Caries
    Taghiloo, Hamid
    Taghiloo, Sina
    Rahbar, Mahdi
    Safabakhsh, Deniz
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2019, 19 (01):
  • [7] Subjective image quality comparison between two digital dental radiographic systems and conventional dental film
    Ajmal, Muhammed
    Elshinawy, Mohamed I.
    SAUDI DENTAL JOURNAL, 2014, 26 (04) : 145 - 150
  • [8] Assessment of diagnostic accuracy of a direct digital radiographic-CMOS image with four types of filtered images for the detection of occlusal caries
    Sahu, Rohit Kumar
    Rajguru, Jagadish P.
    Pattnaiak, Naina
    Bardhan, Debajyoti
    Nayak, Bikash
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (01) : 206 - 214
  • [9] Comparison of low-contrast detail detectability with five different conventional and digital radiographic imaging systems
    Neitzel, U
    Böhm, A
    Maack, I
    MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE, 2000, 3981 : 216 - 223
  • [10] MEASUREMENT ACCURACY - COMPARISON OF 2 INTRAORAL DIGITAL RADIOGRAPHIC SYSTEMS, RADIOVISIOGRAPHY-S AND FLASHDENT, WITH ANALOG FILM
    SCARFE, WC
    NORTON, S
    FARMAN, AG