Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems

被引:45
作者
Hintze, H [1 ]
Wenzel, A [1 ]
机构
[1] Aarhus Univ, Royal Dent Coll, Dept Oral Radiol, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
digital radiography; dental; dental caries; diagnostic test; ROC curve;
D O I
10.1038/sj.dmfr.4600645
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the influence of the validation method on the diagnostic accuracy and the relative comparison of eight radiographic systems for caries detection. Methods: Three hundred and thirty-eight approximal and 145 occlusal surfaces were radiographed under standardised conditions using six CCD-based sensor systems: MPDx (Dental/Medical Diagnostic Systems Inc., Woodland Hills, CA, USA), Dixi (Planmeca, Helsinki, Finland), Sidexis (Sirona, Bensheim, Germany), RVG(old) (Trophy, Paris, France, 1994 model), RVG(new) (Trophy, Paris, France, 2000 model) and Visualix (Gendex, Milan, Italy) and two film systems: Ektaspeed Plus and Insight (Eastman Kodak, Rochester, NY, USA). Four observers examined the radiographs for approximal and occlusal caries using a five-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (A(z)). Results: For both approximal and occlusal caries the mean A(z) of the eight radiographic systems was significantly higher using radiographic than histological validation (P<0.001). Using histological validation for approximal caries, Dixi (A(z)=0.71) and Ektaspeed Plus (A(z)=0.7) were not significantly different, but Dixi was significantly more accurate than the other digital systems and the Insight film. Using radiographic validation for approximal caries, Ektaspeed Plus (A(z)=0.87) was significantly more accurate than Dixi (A(z)=0.82). Dixi was significantly more accurate than MPDx (A(z) = 0.74), RVG(old) (A(z) = 0.77), RVG(new) (A(z) = 0.77) and Visualix (A(z)= 0.76). Corresponding variations were found for occlusal caries depending on the validation method. Using histological validation, MPDx (A(z)=0.76) was significantly less accurate than Dixi (A(z)=0.81), Sidexis (A(z)=0.8), Ektaspeed Plus (A(z)=0.82) and Insight (A(z)=0.81). Using radiographic validation, MPDx (A(z)=0.83) was also significantly less accurate than RVG(old) (A(z)= 0.89) and RVG(new) (A(z) = 0.9). Conclusion: A(z) obtained from radiographic validation was significantly higher than A(z) obtained from histological validation. Comparison of the diagnostic efficacy for caries of the eight radiographic systems was strongly influenced by the validation method.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 22 条
[1]   Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection [J].
Abreu, M ;
Mol, A ;
Ludlow, JB .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2001, 91 (03) :381-385
[2]   Occlusal caries diagnosis: an in vitro histological validation of the Electronic Caries Monitor (ECM) and other methods [J].
Ashley, PF ;
Blinkhorn, AS ;
Davies, RM .
JOURNAL OF DENTISTRY, 1998, 26 (02) :83-88
[3]  
Firestone A R, 1994, Schweiz Monatsschr Zahnmed, V104, P719
[4]  
GJORUP T, 1988, KLIN VURDERING DIAGN
[5]  
GRONDAHL HG, 1979, SWED DENT J S, V3, P1
[6]   CLINICALLY UNDETECTED DENTAL-CARIES ASSESSED BY BITEWING SCREENING IN CHILDREN WITH LITTLE CARIES EXPERIENCE [J].
HINTZE, H ;
WENZEL, A .
DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (01) :19-23
[7]   STEREOMICROSCOPY, FILM RADIOGRAPHY, MICRORADIOGRAPHY AND NAKED-EYE INSPECTION OF TOOTH SECTIONS AS VALIDATION FOR OCCLUSAL CARIES DIAGNOSIS [J].
HINTZE, H ;
WENZEL, A ;
LARSEN, MJ .
CARIES RESEARCH, 1995, 29 (05) :359-363
[8]   Effect of noise on the compressibility and diagnostic accuracy for caries detection of digital bitewing radiographs [J].
Janhom, A ;
van der Stelt, PF ;
van Ginkel, FC ;
Geraets, WGM .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (01) :6-12
[9]   Interaction between noise and file compression and its effect on the recognition of caries in digital imaging [J].
Janhom, A ;
van der Stelt, PF ;
van Ginkel, FC .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) :20-27
[10]   Performance of a new F-speed film for caries detection [J].
Ludlow, JB ;
Abreu, M ;
Mol, A .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (02) :110-113