Magnetic resonance imaging of the active second stage of labour: Proof of principle

被引:7
作者
Guettler, F. V. [1 ]
Heinrich, A. [1 ]
Rump, J. [1 ]
de Bucourt, M. [1 ]
Schnackenburg, B. [3 ]
Bamberg, C. [2 ]
Hamm, B. [1 ]
Teichgraeber, U. K. [1 ]
机构
[1] Charite, Dept Radiol, D-10117 Berlin, Germany
[2] Charite, Dept Obstet, D-10117 Berlin, Germany
[3] Philips GmbH Unternehmensbereich Healthcare, D-20099 Hamburg, Germany
关键词
Parturition; Magnetic resonance imaging; Prenatal diagnosis; Pregnancy; Obstetrics; IN-VITRO EVALUATION; VAGINAL DELIVERY; PELVIC FLOOR; CELL-CYCLE; CHILDBIRTH; PREGNANCY; MRI; INCONTINENCE; FIBROBLASTS; PARAMETERS;
D O I
10.1007/s00330-012-2455-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prove that magnetic resonance imaging of foetal anatomy during the active second stage of vaginal delivery is feasible. Initially, five pregnant volunteers around the 30th week of gestation were examined in an open MRI. Based on the findings, one vaginal delivery was acquired under real-time imaging. To monitor the birth status during image acquisition, an MR-compatible wireless cardiotocography (CTG) system was built. Single-shot sequence parameters were optimised to compensate motion artefacts during labour. Safety requirements to monitor the birth process under real-time MR imaging were met. High-resolution MR images were acquired immediately before and after delivery. In one patient, TSE single-shot cinematic sequences of the active second stage of labour were obtained. All sequences were adapted to tolerate movement of the mother and infant, as well as residual noise from the CTG. Furthermore, the MR imaging during labour showed only minor image artefacts. CTG-monitored acquisition of MRI series during the active second stage of delivery is feasible. Image quality should allow various further studies to improve models for birth simulation as well as potential investigation of obstructed labour and obstetric complications. aEuro cent The active second stage of obstetric delivery can be followed by MRI. aEuro cent Wireless cardiotocography allows monitoring of the foetus during MRI. aEuro cent It has potential applications in evaluation of late obstetric problems.
引用
收藏
页码:2020 / 2026
页数:7
相关论文
共 30 条
  • [1] [Anonymous], 1994, INT J GYNAECOL OBSTE, V44, P289
  • [2] [Anonymous], 2006, F205206E1 ASTM INT
  • [3] *ASTM INT, 2008, F250308 ASTM INT
  • [4] *ASTM INT, 2007, F211907 ASTM INT
  • [5] Women's position during labour: influence on maternal and neonatal outcome
    Bodner-Adler, B
    Bodner, K
    Kimberger, O
    Lozanov, P
    Husslein, P
    Mayerhofer, K
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2003, 115 (19-20) : 720 - 723
  • [6] Influence of different maternal birth positions on perineal trauma and neonatal parameters during spontaneous vaginal delivery
    Bodner-Adler, B
    Bodner, K
    Joura, EA
    Husslein, P
    Wagenbichler, P
    Kaider, A
    Mayerhofer, K
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 2001, 61 (10) : 766 - 770
  • [7] Gei A, 2009, INT J GYNECOL OBSTET, V107, pS477
  • [8] Guettler FV, 2011, OPEN SOURCE MR SUSCE
  • [9] Absence of harmful effects of magnetic resonance exposure at 1.5 T in utero during the third trimester of pregnancy: a follow-up study
    Kok, RD
    de Vries, MM
    Heerschap, A
    van den Berg, PP
    [J]. MAGNETIC RESONANCE IMAGING, 2004, 22 (06) : 851 - 854
  • [10] Kolbl H, 2001, Zentralbl Gynakol, V123, P666, DOI 10.1055/s-2001-20016