On the validity of 3D polymer gel dosimetry: I. Reproducibility study

被引:61
作者
Vandecasteele, Jan [1 ]
De Deene, Yves [1 ]
机构
[1] Univ Ghent, Dept Radiat Oncol & Expt Canc Res, B-9000 Ghent, Belgium
关键词
RADIATION-DOSE DISTRIBUTIONS; HYDROXYMETHYL PHOSPHONIUM CHLORIDE; METHACRYLIC-ACID; CALIBRATION; MRI; ACCURACY; PAG; RADIOTHERAPY; VERIFICATION; ARTIFACTS;
D O I
10.1088/0031-9155/58/1/19
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The intra- and inter-batch accuracy and precision of MRI (polyacrylamide gelatin gel fabricated at atmospheric conditions) polymer gel dosimeters are assessed in full 3D. In the intra-batch study, eight spherical flasks were filled with the same polymer gel along with a set of test tubes that served as calibration phantoms. In the inter-batch study, the eight spherical flasks were filled with different batches of gel. For each spherical phantom, a separate set of calibration phantoms was used. The spherical phantoms were irradiated using a three-field coplanar beam configuration in a very reproducible manner. The calibration phantoms were irradiated to known doses to obtain a dose-R-2 calibration plot which was applied on the corresponding R-2 maps of all spherical phantoms on an individual basis. The intra-batch study showed high dosimetric precision (3.1%) notwithstanding poor accuracy (mean dose discrepancies up to 13.0%). In the inter-batch study, a similar dosimetric precision (4.3%) and accuracy (mean dose discrepancies up to 13.7%) were found. The poor dosimetric accuracy was attributed to a systematic fault that was related to the calibration method. Therefore, the dose maps were renormalized using an independent ion chamber dose measurement. It is illustrated that with this renormalization, excellent agreement between the gel measured and TPS calculated 3D dose maps is achievable: 97% and 99% of the pixels meet the 3%/3 mm criteria for the intra-and inter-batch experiments, respectively. However renormalization will result in significant dose deviations inside a realistically sized anthropomorphic phantom as will be shown in a concurrent paper.
引用
收藏
页码:19 / 42
页数:24
相关论文
共 55 条
  • [1] Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry
    Baldock, C
    Burford, RP
    Billingham, N
    Wagner, GS
    Patval, S
    Badawi, RD
    Keevil, SF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03) : 695 - 702
  • [2] Dose resolution in radiotherapy polymer gel dosimetry:: effect of echo spacing in MRI pulse sequence
    Baldock, C
    Lepage, M
    Bäck, SÅJ
    Murry, PJ
    Jayasekera, PM
    Porter, D
    Kron, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) : 449 - 460
  • [3] Uncertainty analysis in polymer gel dosimetry
    Baldock, C
    Murry, P
    Kron, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) : N243 - N246
  • [4] Liquid ionization chamber calibrated gel dosimetry in conformal stereotactic radiotherapy of brain lesions
    Bjoreland, Anders
    Lindvall, Peter
    Karlsson, Anna
    Gustavsson, Helen
    Back, Sven Aj
    Karlsson, Mikael
    Bergenheim, Tommy A.
    [J]. ACTA ONCOLOGICA, 2008, 47 (06) : 1099 - 1109
  • [5] A self consistent normalized calibration protocol for three dimensional magnetic resonance gel dosimetry
    Cardenas, RL
    Cheng, KH
    Verhey, LJ
    Xia, P
    Davis, L
    Cannon, B
    [J]. MAGNETIC RESONANCE IMAGING, 2002, 20 (09) : 667 - 679
  • [6] Verification of dynamic radiotherapy:: the potential for 3D dosimetry under respiratory-like motion using polymer gel
    Ceberg, S.
    Karlsson, A.
    Gustavsson, H.
    Wittgren, L.
    Back, S. A. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20) : N387 - N396
  • [7] RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation
    Ceberg, Sofie
    Gagne, Isabelle
    Gustafsson, Helen
    Scherman, Jonas Bengtsson
    Korreman, Stine S.
    Kjaer-Kristoffersen, Flemming
    Hilts, Michelle
    Back, Sven A. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) : 4885 - 4898
  • [8] The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy
    Cosgrove, VP
    Murphy, PS
    McJury, M
    Adams, EJ
    Warrington, AP
    Leach, MO
    Webb, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) : 1195 - 1210
  • [9] Introducing gel dosimetry in a clinical environment: Customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy
    Crescenti, Remo A.
    Scheib, Stefan G.
    Schneider, Uwe
    Gianolini, Stefano
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1286 - 1297
  • [10] The influence of cooling rate on the accuracy of normoxic polymer gel dosimeters
    De Deene, Y.
    Pittomvils, G.
    Visalatchi, S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (10) : 2719 - 2728