The Epidemiology of Microbial Keratitis With Silicone Hydrogel Contact Lenses

被引:55
|
作者
Stapleton, Fiona [1 ,2 ,3 ]
Keay, Lisa [2 ,3 ]
Edwards, Katie [2 ,3 ]
Holden, Brien [1 ,2 ,3 ]
机构
[1] Brien Holden Vis Inst, Sydney, NSW, Australia
[2] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
[3] Vis Cooperat Res Ctr, Sydney, NSW, Australia
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2013年 / 39卷 / 01期
基金
英国医学研究理事会;
关键词
Corneal infection; Contact lens; Microbial keratitis; Silicone hydrogel; RISK-FACTORS; DAILY-WEAR; ULCERATIVE KERATITIS; CORNEAL EPITHELIUM; BACTERIAL BINDING; SEVERITY; EVENTS; USERS; SIZE;
D O I
10.1097/ICL.0b013e3182713919
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
It was widely anticipated that after the introduction of silicone hydrogel lenses, the risk of microbial keratitis would be lower than with hydrogel lenses because of the reduction in hypoxic effects on the corneal epithelium. Large-scale epidemiological studies have confirmed that the absolute and relative risk of microbial keratitis is unchanged with overnight use of silicone hydrogel materials. The key findings include the following: (1) The risk of infection with 30 nights of silicone hydrogel use is equivalent to 6 nights of hydrogel extended wear; (2) Occasional overnight lens use is associated with a greater risk than daily lens use; (3) The rate of vision loss due to corneal infection with silicone hydrogel contact lenses is similar to that seen in hydrogel lenses; (4) The spectrum of causative organisms is similar to that seen in hydrogel lenses, and the material type does not impact the corneal location of presumed microbial keratitis; and (5) Modifiable risk factors for infection include overnight lens use, the degree of exposure, failing to wash hands before lens handling, and storage case hygiene practice. The lack of change in the absolute risk of disease would suggest that exposure to large number of pathogenic organisms can overcome any advantages obtained from eliminating the hypoxic effects of contact lenses. Epidemiological studies remain important in the assessment of new materials and modalities. Consideration of an early adopter effect with studies involving new materials and modalities and further investigation of the impact of second-generation silicone hydrogel materials is warranted.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [41] Phomopsidione nanoparticles coated contact lenses reduce microbial keratitis causing pathogens
    Bin Sahadan, Muhammad Yusoff
    Tong, Woei Yenn
    Tan, Wen Nee
    Leong, Chean Ring
    Bin Misri, Mohamad Najib
    Chan, Murphy
    Cheng, See Yuan
    Shaharuddin, Shahrulzaman
    EXPERIMENTAL EYE RESEARCH, 2019, 178 : 10 - 14
  • [42] Contact lens induced papillary conjunctivitis with silicone hydrogel lenses
    Sorbara, L.
    Jones, L.
    Williams-Lyn, D.
    CONTACT LENS & ANTERIOR EYE, 2009, 32 (02) : 93 - 96
  • [43] Mucin balls with wear of conventional and silicone hydrogel contact lenses
    Tan, J
    Keay, L
    Jalbert, I
    Naduvilath, TJ
    Sweeney, DF
    Holden, BA
    OPTOMETRY AND VISION SCIENCE, 2003, 80 (04) : 291 - 297
  • [44] Contact lens-related microbial keratitis .1. Epidemiology
    Liesegang, TJ
    CORNEA, 1997, 16 (02) : 125 - 131
  • [45] Impact of Cosmetics on the Surface Properties of Silicone Hydrogel Contact Lenses
    Srinivasan, Sruthi
    Otchere, Heinz
    Yu, Mili
    Yang, Jeffery
    Luensmann, Doerte
    Jones, Lyndon
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (04): : 228 - 235
  • [46] Bacterial Adhesion to Unworn and Worn Silicone Hydrogel Lenses
    Vijay, Ajay Kumar
    Zhu, Hua
    Ozkan, Jerome
    Wu, Duojia
    Masoudi, Simin
    Bandara, Rani
    Borazjani, Roya N.
    Willcox, Mark D. P.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (08) : 1095 - 1106
  • [47] Comfort and adaptation to silicone hydrogel lenses for daily wear
    Dumbleton, Kathryn A.
    Woods, Craig A.
    Jones, Lyndon W.
    Fonn, Desmond
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (04): : 215 - 223
  • [48] Comfort and Vision with Silicone Hydrogel Lenses: Effect of Compliance
    Dumbleton, Kathryn
    Woods, Craig
    Jones, Lyndon
    Richter, Doris
    Fonn, Desmond
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (06) : 421 - 425
  • [49] Wettability and Silicone Hydrogel Lenses: A Review
    Keir, Nancy
    Jones, Lyndon
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 100 - 108
  • [50] Solutions for Care of Silicone Hydrogel Lenses
    Willcox, Mark D. P.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 24 - 28