The Epidemiology of Microbial Keratitis With Silicone Hydrogel Contact Lenses

被引:55
|
作者
Stapleton, Fiona [1 ,2 ,3 ]
Keay, Lisa [2 ,3 ]
Edwards, Katie [2 ,3 ]
Holden, Brien [1 ,2 ,3 ]
机构
[1] Brien Holden Vis Inst, Sydney, NSW, Australia
[2] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
[3] Vis Cooperat Res Ctr, Sydney, NSW, Australia
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2013年 / 39卷 / 01期
基金
英国医学研究理事会;
关键词
Corneal infection; Contact lens; Microbial keratitis; Silicone hydrogel; RISK-FACTORS; DAILY-WEAR; ULCERATIVE KERATITIS; CORNEAL EPITHELIUM; BACTERIAL BINDING; SEVERITY; EVENTS; USERS; SIZE;
D O I
10.1097/ICL.0b013e3182713919
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
It was widely anticipated that after the introduction of silicone hydrogel lenses, the risk of microbial keratitis would be lower than with hydrogel lenses because of the reduction in hypoxic effects on the corneal epithelium. Large-scale epidemiological studies have confirmed that the absolute and relative risk of microbial keratitis is unchanged with overnight use of silicone hydrogel materials. The key findings include the following: (1) The risk of infection with 30 nights of silicone hydrogel use is equivalent to 6 nights of hydrogel extended wear; (2) Occasional overnight lens use is associated with a greater risk than daily lens use; (3) The rate of vision loss due to corneal infection with silicone hydrogel contact lenses is similar to that seen in hydrogel lenses; (4) The spectrum of causative organisms is similar to that seen in hydrogel lenses, and the material type does not impact the corneal location of presumed microbial keratitis; and (5) Modifiable risk factors for infection include overnight lens use, the degree of exposure, failing to wash hands before lens handling, and storage case hygiene practice. The lack of change in the absolute risk of disease would suggest that exposure to large number of pathogenic organisms can overcome any advantages obtained from eliminating the hypoxic effects of contact lenses. Epidemiological studies remain important in the assessment of new materials and modalities. Consideration of an early adopter effect with studies involving new materials and modalities and further investigation of the impact of second-generation silicone hydrogel materials is warranted.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [21] Clinical Investigation of Asmofilcon A Silicone Hydrogel Lenses
    Lakkis, Carol
    Vincent, Stephen
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (04) : 350 - 356
  • [22] Efficacy of two silicone-hydrogel contact lenses for bandage use after photorefractive keratectomy
    Plaka, A.
    Grentzelos, M. A.
    Astyrakakis, N. I.
    Kymionis, G. D.
    Pallikaris, I. G.
    Plainis, S.
    CONTACT LENS & ANTERIOR EYE, 2013, 36 (05) : 243 - 246
  • [23] Ion transport in silicone hydrogel contact lenses
    Peng, Cheng-Chun
    Chauhan, Anuj
    JOURNAL OF MEMBRANE SCIENCE, 2012, 399 : 95 - 105
  • [24] Contact Lens Lipid Spoliation of Hydrogel and Silicone Hydrogel Lenses
    Maissa, Cecile
    Guillon, Michel
    Cockshott, Nik
    Garofalo, Renee J.
    Lemp, Jessie M.
    Boclair, Joseph W.
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (09) : 1071 - 1083
  • [25] Risk Factors for Microbial Bioburden During Daily Wear of Silicone Hydrogel Contact Lenses
    Jiang, Ying
    Jacobs, Michael
    Bajaksouzian, Saralee
    Foster, Altreisha N.
    Debanne, Sara M.
    Bielefeld, Roger
    Garvey, Matt
    Raghupathy, Sangeetha
    Kern, Jami
    Szczotka-Flynn, Loretta B.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (03): : 148 - 156
  • [26] In Vitro and In Vivo Evaluation of Novel Ciprofloxacin-Releasing Silicone Hydrogel Contact Lenses
    Hui, Alex
    Willcox, Mark
    Jones, Lyndon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) : 4896 - 4904
  • [27] Eye care professionals' perceptions of the benefits of daily disposable silicone hydrogel contact lenses
    Orsborn, Gary
    Dumbleton, Kathy
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (04) : 373 - 379
  • [28] The effect of hydrogel and silicone hydrogel contact lenses on the measurement of intraocular pressure with rebound tonometry
    Zeri, Fabrizio
    Calcatelli, Paolo
    Donini, Bernardo
    Lupelli, Luigi
    Zarrilli, Luciana
    Swann, Peter G.
    CONTACT LENS & ANTERIOR EYE, 2011, 34 (06) : 260 - 265
  • [29] Mechanical Complications Induced by Silicone Hydrogel Contact Lenses
    Lin, Meng C.
    Yeh, Thao N.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 115 - 124
  • [30] Albumin Acts as a Lubricant on the Surface of Hydrogel and Silicone Hydrogel Contact Lenses
    Su, Chen-Ying
    Yeh, Lung-Kun
    Fan, Tzu-Wei
    Lai, Chi-Chun
    Fang, Hsu-Wei
    POLYMERS, 2021, 13 (13)