Further experimental evidence of the compressibility of arteries

被引:17
作者
Yossef, Ofry Efraim [1 ]
Farajian, Mor [1 ]
Gilad, Ilan [1 ]
Willenz, Udi [2 ]
Gutman, Nimrod [2 ]
Yosibash, Zohar [1 ]
机构
[1] Ben Gurion Univ Negev, Dept Mech Engn, IL-84105 Beer Sheva, Israel
[2] Lahav CRO, IL-85335 Kibbutz Lahav, Israel
关键词
Artery; Compressibility; Experimental observations;
D O I
10.1016/j.jmbbm.2016.08.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Further experimental evidence on the compressibility of arteries under normal physiological pressure range is provided using the experimental apparatus introduced in Yosibash et al., JMBBM 39(2014):339-354. We enlarged the experimental database by including almost twice the number of experiments, we considered a different artery - the porcine common carotid that allowed longer and larger diameters. In the physiological pressure range of 50-200 mmHg, a relative volume change of 5% was obtained, lower compared to the sapheneous and femoral arteries (2-6%). Most of the arteries had a relative volume change of 1.5%. The relative volume change is found to be almost linearly proportional to the pressure, and inversely proportional to the dimensions of the experimented arteries (especially the artery length). The smaller the artery tested, the larger the relative volume change (such a phenomenon was also realized in Yosibash et al., JMBBM 39(2014):339-354.). We realized in recent past publications a flaw in the experimental protocol that results in an overestimation of the relative volume change (thus underestimating the bulk modulus). It is due to the consideration of experimental observations close to the zero pressure. Nontheless, in view of the experimental evidence, the pre-assumption of incompressibility in many phenomenological constitutive models of artery walls should be re-evaluated. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 189
页数:13
相关论文
共 8 条
  • [1] Active axial stress in mouse aorta
    Agianniotis, A.
    Rachev, A.
    Stergiopulos, N.
    [J]. JOURNAL OF BIOMECHANICS, 2012, 45 (11) : 1924 - 1927
  • [2] Comparison of femoral and auricular arterial blood pressure monitoring in pigs
    Bass, Louise M. E.
    Yu, Dao-Yi
    Cullen, Len K.
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2009, 36 (05) : 457 - 463
  • [3] Review of Experimental Investigations on Compressibility of Arteries and Introduction of a New Apparatus
    Di Puccio, F.
    Celi, S.
    Forte, P.
    [J]. EXPERIMENTAL MECHANICS, 2012, 52 (07) : 895 - 902
  • [4] Biomechanical Phenotyping of Central Arteries in Health and Disease: Advantages of and Methods for Murine Models
    Ferruzzi, J.
    Bersi, M. R.
    Humphrey, J. D.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (07) : 1311 - 1330
  • [5] Hannon J., 1989, TECH REP
  • [6] Constitutive modelling of arteries
    Holzapfel, Gerhard A.
    Ogden, Ray W.
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2010, 466 (2118): : 1551 - 1596
  • [7] On the Compressibility of Arterial Tissue
    Nolan, D. R.
    McGarry, J. P.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (04) : 993 - 1007
  • [8] Experimental evidence of the compressibility of arteries
    Yosibash, Zohar
    Manor, Itay
    Gilad, Ilan
    Willentz, Udi
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 39 : 339 - 354