Comparison of measured total suspended particulate matter concentrations using tapered element oscillating microbalance and a total suspended particulate sampler

被引:20
作者
Jerez, SB
Zhang, YH
McClure, JW
Jacobson, L
Heber, A
Hoff, S
Koziel, J
Beasley, D
机构
[1] Univ Illinois, Dept Agr & Biol Engn, Urbana, IL 61801 USA
[2] Univ Minnesota, Dept Biosyst & Agr Engn, St Paul, MN 55108 USA
[3] Purdue Univ, Dept Agr & Biol Engn, W Lafayette, IN 47907 USA
[4] Iowa State Univ, Dept Agr Biosyst Engn, Ames, IA USA
[5] N Carolina State Univ, Dept Biol & Agr Engn, Raleigh, NC 27695 USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 2006年 / 56卷 / 03期
关键词
D O I
10.1080/10473289.2006.10464460
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A comparison of the concentration of the total suspended particulate (TSP) matter measured by the tapered element oscillating microbalance (TEOM) monitor and the isokinetic TSP samplers developed at the University of Illinois was carried out in several types of confinement livestock buildings. In a majority of the measurements done, the dust concentration measured by the TEOM monitor was lower than the University of Illinois at Urbana-Champaign (UIUC) isokinetic TSP sampler; the TEOM monitor tended to underestimate the total dust concentration by as much as 54%. The difference in measurements can be attributed to the sampling efficiency of the TEOM monitor sampling head and the loss of some semivolatile compounds and particle-bound water because of heating of the TEOM monitor sampling.stream to 50 degrees C. Although several articles in the literature supported the latter argument, this study did not investigate the effect of heating the sampling stream or the effect of moisture on the relative difference in dust concentration measurements. The model that best describes the relationship between the two methods was site specific, that is, the linear regression model was applicable only to four of the sites monitored. The measured total dust concentration in livestock buildings range from similar to 300 to 4000 mu g/m(3); a higher correlation coefficient between TEOM-TSP and UIUC-TSP monitors was obtained in swine facilities than those obtained in a laying facility.
引用
收藏
页码:261 / 270
页数:10
相关论文
共 17 条
[1]   TEOM vs. manual gravimetric methods for determination of PM2.5 aerosol mass concentrations [J].
Ayers, GP ;
Keywood, MD ;
Gras, JL .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (22) :3717-3721
[2]  
Baltensperger U., 2001, AEROSOL MEASUREMENT, P387
[3]   Quantitative interpretation of divergence between PM10 and PM2.5 mass measurement by TEOM and gravimetric (Partisol) instruments [J].
Charron, A ;
Harrison, RM ;
Moorcroft, S ;
Booker, J .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (03) :415-423
[4]  
Donham K., 1999, P INT S DUST CONTR A
[5]  
HINDS WC, 1982, AEROSOL TECHNOLOGY, P187
[6]   A comprehensive experimental study of aerial pollutants in and emissions from livestock buildings. Part 1. Methods [J].
Hinz, T ;
Linke, S .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1998, 70 (01) :111-118
[7]  
LIM TT, P AIR POLLUTION AGR, V3
[8]  
MCCLURE J, P 97 ANN M EXH A WMA
[9]  
MEYER M, 1992, J AIR WASTE MANAGE, V21, P24
[10]   CONTINUOUS PM-10 MEASUREMENTS USING THE TAPERED ELEMENT OSCILLATING MICROBALANCE [J].
PATASHNICK, H ;
RUPPRECHT, EG .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (08) :1079-1083