Helical computerized tomography arteriography for evaluation of live renal donors undergoing laparoscopic nephrectomy

被引:60
作者
Del Pizzo, JJ
Sklar, GN
You-Cheong, JW
Levin, B
Krebs, T
Jacobs, SC
机构
[1] Univ Maryland, Sch Med, Div Urol, Dept Surg, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Radiol, Baltimore, MD 21201 USA
关键词
tomography; angiography; laparoscopy; kidney transplantation;
D O I
10.1097/00005392-199907000-00008
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Traditionally, live renal donors are evaluated with excretory urography and renal arteriography. Helical computerized tomography (CT) arteriography offers a less invasive alternative for demonstrating necessary anatomical information before laparoscopic allograft harvest. We evaluate the accuracy of helical CT arteriography in depicting renal vascular anatomy with an emphasis on the detection of arterial and venous anomalies. Materials and Methods: Imaging studies were done on 175 patients according to a standard CT arteriography protocol with early arterial phase scanning (14 to 20-second delay), and 1 mm. axial and 3-dimensional maximum intensity projection reconstructions. Renal vascular anatomy was mapped with attention to aberrant arterial and venous anatomy. Intraoperative findings were correlated at laparoscopic donor nephrectomy. Results: There was overall agreement between CT arteriography and laparoscopic findings in 163 cases (93%). Supernumerary renal arteries were identified in 40 cases (23%). Sensitivity, specificity and accuracy of CT arteriography for arterial anatomy were 91, 98 and 96%, respectively. Cases with less than 2 mm. accessory arteries or early branching single vessels simulating dual arteries were misdiagnosed. Venous anomalies occurred in 11 patients (6.3%). Sensitivity, specificity and accuracy of CT arteriography for venous anatomy were 65, 100, and 97%, respectively. Misdiagnoses included early venous bifurcations and supernumerary tributary veins, which were poorly opacified. Conclusions: Helical CT is highly accurate and specific for the demonstration of renal arterial anatomy. Poor opacification resulted in a lower sensitivity for venous anatomy. Overall, helical CT provides essential anatomical information, and is an alternative to standard urography and arteriography.
引用
收藏
页码:31 / 34
页数:4
相关论文
共 13 条
  • [1] SPIRAL CT ANGIOGRAPHY - AN ALTERNATIVE TO CONVENTIONAL ANGIOGRAPHY
    BLUEMKE, DA
    CHAMBERS, TP
    [J]. RADIOLOGY, 1995, 195 (02) : 317 - 319
  • [2] Helical CT angiography for examination of living renal donors
    Cochran, ST
    Krasny, RM
    Danovitch, GM
    Rajfer, J
    Barbaric, ZM
    Wilkinson, A
    Rosenthal, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) : 1569 - 1573
  • [3] DASHMAN AH, 1998, AJR, V171, P193
  • [4] DERAUF B, 1987, RADIOL CLIN N AM, V25, P261
  • [5] KJELLEVAND TO, 1991, ACTA RADIOL, V32, P368
  • [6] Lowell J A, 1994, Semin Urol, V12, P102
  • [7] Helical CT evaluation of potential kidney donors: Findings in 154 subjects
    Platt, JF
    Ellis, JH
    Korobkin, M
    Reige, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) : 1325 - 1330
  • [8] SELECTION CRITERIA FOR THE EVALUATION OF LIVING RELATED RENAL DONORS
    RIEHLE, RA
    STECKLER, R
    NASLUND, EB
    RIGGIO, R
    CHEIGH, J
    STUBENBORD, W
    [J]. JOURNAL OF UROLOGY, 1990, 144 (04) : 845 - 848
  • [9] ASSESSMENT OF LIVING RENAL DONORS WITH SPIRAL CT
    RUBIN, GD
    ALFREY, EJ
    DAKE, MD
    SEMBA, CP
    SOMMER, FG
    KUO, PC
    DAFOE, DC
    WASKERWITZ, JA
    BLOCH, DA
    JEFFREY, RB
    [J]. RADIOLOGY, 1995, 195 (02) : 457 - 462
  • [10] RENAL ANGIOGRAPHY PROBLEMS IN LIVE KIDNEY DONORS
    SHERWOOD, T
    RUUTU, M
    CHISHOLM, GD
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1978, 51 (602) : 99 - 105