Development of square-wave adsorptive stripping voltammetric method for determination of acebutolol in pharmaceutical formulations and biological fluids
被引:36
作者:
Al-Ghamdi, Ali F.
论文数: 0引用数: 0
h-index: 0
机构:
Taibah Univ, Coll Sci, Dept Chem, Al Madinah Al Munawarah, Saudi ArabiaKing Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
Al-Ghamdi, Ali F.
[2
]
Hefnawy, Mohamed M.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi ArabiaKing Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
Hefnawy, Mohamed M.
[1
]
论文数: 引用数:
h-index:
机构:
Al-Majed, Abdulrahman A.
[1
]
Belal, Fatallah F.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Mansoura, Fac Pharm, Dept Analyt Chem, Mansoura 35516, EgyptKing Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
Belal, Fatallah F.
[3
]
机构:
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
[2] Taibah Univ, Coll Sci, Dept Chem, Al Madinah Al Munawarah, Saudi Arabia
A validated simple, rapid, sensitive and specific square-wave voltammetric technique is described for the determination of acebutolol (AC) following its accumulation onto a hanging mercury drop electrode in a Britton-Robinson universal buffer of pH 7.5. The optimal procedural conditions were: accumulation potential E-acc = -0.8 V versus Ag/AgCl/KCl, accumulation duration t(acc) = 30 s, pulse-amplitude = 70 mV, scan rate = 100 mV/s, frequency = 30 Hz, surface area of the working electrode = 0.6 mm(2) and the convection rate = 2000 rpm. Under these optimized conditions, the adsorptive stripping voltammetry (AdSV) peak current was proportional over the concentration range 5 x 10(-7) - 6 x 10(-6) M (r = 0.999). Recoveries for acebutolol from human plasma and urine were in the range 97-103% and 96-104% respectively. The method proved to be precise (intra-day precision expressed as %RSD in human plasma ranged from 2.9 - 3.2% and inter-day precision expressed as %RSD ranged from 3.4 - 3.8%) and accurate (intra-day accuracies expressed as % error in human urine ranged from -3.3 - 2.8% and inter-day accuracies ranged from -3.3 - 1.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for acebutolol were 1.7 x 10(-7) and 5 x 10(-7) M, respectively. Possible interferences by substances usually present in the pharmaceutical formulations were investigated with a mean recovery of 101.6 +/- 0.64%. Results of the developed square-wave adsorptive stripping voltammetry (SW-AdSV) method were comparable with those obtained by reference analytical method.