Noninvasive and nonocclusive determination of blood pressure using laser Doppler flowmetry

被引:2
|
作者
Elter, P [1 ]
Stork, W [1 ]
Müller-Glaser, KD [1 ]
Lutter, N [1 ]
机构
[1] Univ Karlsruhe, Inst Informat Proc Technol, D-76128 Karlsruhe, Germany
来源
SPECIALTY FIBER OPTICS FOR MEDICAL APPLICATIONS, PROCEEDINGS OF | 1999年 / 3596卷
关键词
blood pressure; noninvasive; laser; Doppler; flowmetry;
D O I
10.1117/12.346715
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This report describes an approach determining blood pressure noninvasively without cuff. Regarding an elastic, fluid-filled tube as a model of an arterial segment, the solution of the Navier Stokes differential equations delivers a relation between the pressure and velocity pulse. There, simulations prove a minimal sensitivity of blood pressure concerning blood density, blood viscosity and damping. Hence, these parameters can be regarded interindividually as constants. Blood pressure is essentially sensitive on the pulse wave velocity, the velocity pulse, the arterial diameter and the reflection coefficient. To perform measurements, a system was built up comprising at least one laser Doppler blood flow sensor, a high performance DSP hardware and a PC. After individual initial Riva Rocci calibration, arterial diameter and reflection coefficient can be determined. Flow and pulse wave velocity and thus blood pressure can be calculated measuring continuously at least one velocity pulse with the laser Doppler flow sensor at a superficial artery like the a. radialis and simultaneously another cardiovascular signal like an ECG or another flow pulse at a different site of the artery. As a first result, high linear correlations between systolic blood pressure and pulse transit time were obtained.
引用
收藏
页码:188 / 196
页数:9
相关论文
共 50 条
  • [31] A comparison of Doppler flowmetry with conventional assessment of acute changes in hepatic blood flow
    Gibson, PR
    Gibson, RN
    Donlan, JD
    Jones, PA
    Colman, JC
    Dudley, FJ
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1996, 11 (01) : 14 - 20
  • [32] Application of the laser Doppler flowmeter for measurement of blood pressure and functional parameters of microcirculation
    Hu, Chang-Lin
    Lin, Zhan-Sheng
    Chen, Yen-Yu
    Lin, Yuan-Hsiang
    Lai, Mei-Feng
    Li, Meng-Lin
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2012, 22 (06) : 351 - 359
  • [33] Sample size determination in the laser-Doppler measurements of skin blood flow
    Stepanov, Rodion
    Podtaev, Sergey
    Tsiberkin, Kirill
    MICROVASCULAR RESEARCH, 2019, 125
  • [34] A Cluster Method to Noninvasive Continuous Blood Pressure Measurement Using PPG
    Miao, Yu
    Zhang, Zhiqiang
    Meng, Lifang
    Xie, Xiaoqin
    Pan, Haiwei
    SMART HEALTH, ICSH 2016, 2017, 10219 : 109 - 120
  • [35] Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach
    Teng, XF
    Zhang, YT
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3153 - 3156
  • [36] Acoustic resolution photoacoustic Doppler flowmetry using a transducer array: optimising processing for velocity contrast
    Bucking, T. M.
    van den Berg, P. J.
    Balabani, S.
    Steenbergen, W.
    Beard, P. C.
    Brunker, J.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [37] The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure
    Qing Shangguan
    Wu, Yanqing
    Xu, Jinsong
    Su, Hai
    Li, Juxiang
    Hong, Kui
    Cheng, Xiaoshu
    BLOOD PRESSURE MONITORING, 2015, 20 (06) : 316 - 319
  • [38] Blood Pressure Determination Using Analysis of Biosignals
    Ciz, Radim
    Chmelar, Milan
    RECENT RESEARCHES IN TELECOMMUNICATIONS, INFORMATICS, ELECTRONICS & SIGNAL PROCESSING, 2011, : 188 - +
  • [39] Determination of ankle-brachial index using a portable doppler and a blood pressure measuring device in diabetic patients
    Novo-Garcia, Carmen
    Ciria-Uriel, Javier
    Novo-Garcia, Enrique
    Nino-de Mateo, Mercedes
    ENFERMERIA CLINICA, 2012, 22 (04): : 198 - 204
  • [40] Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator
    P D Davis
    J L Dennis
    R Railton
    Journal of Human Hypertension, 2005, 19 : 197 - 203