Noninvasive and nonocclusive determination of blood pressure using laser Doppler flowmetry

被引:2
|
作者
Elter, P [1 ]
Stork, W [1 ]
Müller-Glaser, KD [1 ]
Lutter, N [1 ]
机构
[1] Univ Karlsruhe, Inst Informat Proc Technol, D-76128 Karlsruhe, Germany
来源
SPECIALTY FIBER OPTICS FOR MEDICAL APPLICATIONS, PROCEEDINGS OF | 1999年 / 3596卷
关键词
blood pressure; noninvasive; laser; Doppler; flowmetry;
D O I
10.1117/12.346715
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This report describes an approach determining blood pressure noninvasively without cuff. Regarding an elastic, fluid-filled tube as a model of an arterial segment, the solution of the Navier Stokes differential equations delivers a relation between the pressure and velocity pulse. There, simulations prove a minimal sensitivity of blood pressure concerning blood density, blood viscosity and damping. Hence, these parameters can be regarded interindividually as constants. Blood pressure is essentially sensitive on the pulse wave velocity, the velocity pulse, the arterial diameter and the reflection coefficient. To perform measurements, a system was built up comprising at least one laser Doppler blood flow sensor, a high performance DSP hardware and a PC. After individual initial Riva Rocci calibration, arterial diameter and reflection coefficient can be determined. Flow and pulse wave velocity and thus blood pressure can be calculated measuring continuously at least one velocity pulse with the laser Doppler flow sensor at a superficial artery like the a. radialis and simultaneously another cardiovascular signal like an ECG or another flow pulse at a different site of the artery. As a first result, high linear correlations between systolic blood pressure and pulse transit time were obtained.
引用
收藏
页码:188 / 196
页数:9
相关论文
共 50 条
  • [1] Noninvasive, real time laser Doppler flowmetry in perfusion regions and larger vessels
    Elter, P
    Seiter, E
    Karch, T
    Stork, W
    Müller-Glaser, KD
    Lutter, N
    BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 : 244 - 254
  • [2] EVALUATION OF GINGIVAL VASCULARISATION USING LASER DOPPLER FLOWMETRY
    Vitez, B.
    Todea, C.
    Velescu, A.
    Sipos, C.
    HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670
  • [3] Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor
    Sola, Josep
    Proenca, Martin
    Ferrario, Damien
    Porchet, Jacques-Andre
    Falhi, Abdessamad
    Grossenbacher, Olivier
    Allemann, Yves
    Rimoldi, Stefano F.
    Sartori, Claudio
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (12) : 3505 - 3513
  • [4] NONINVASIVE DOPPLER BLOOD-PRESSURE MONITORING IN THE MONOPLACE HYPERBARIC CHAMBER
    WEAVER, LK
    HOWE, S
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (04): : 304 - 308
  • [5] Measurement procedures in confocal choroidal laser Doppler flowmetry
    Preitner, A
    Orgül, S
    Prünte, C
    Flammer, J
    CURRENT EYE RESEARCH, 2004, 28 (04) : 233 - 240
  • [6] LASER DOPPLER FLOWMETRY IN THE EVALUATION OF PERIODONTAL HEALTH AND DISEASE
    Firkova, Elena
    Bouka, Maria
    JOURNAL OF IMAB, 2019, 25 (03): : 2599 - 2602
  • [7] Noninvasive prediction of intracranial pressure curves using transcranial Doppler ultrasonography and blood pressure curves
    Schmidt, B
    Klingelhofer, J
    Schwarze, JJ
    Sander, D
    Wittich, I
    STROKE, 1997, 28 (12) : 2465 - 2472
  • [8] LASER-DOPPLER FLOWMETRY IN NEUROSURGERY
    BOLOGNESE, P
    MILLER, JI
    HEGER, IM
    MILHORAT, TH
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1993, 5 (03) : 151 - 158
  • [9] Noninvasive and Nonocclusive Blood Pressure Monitoring via a Flexible Piezo-Composite Ultrasonic Sensor
    Peng, Chang
    Chen, Mengyue
    Sim, Hun Ki
    Zhu, Yong
    Jiang, Xiaoning
    IEEE SENSORS JOURNAL, 2021, 21 (03) : 2642 - 2650
  • [10] Measurement of the cutaneous blood flow reserve in normal humans by laser-Doppler flowmetry
    Vayssairat, M
    Chabbert-Buffet, N
    Gaitz, JP
    Tribout, L
    Abdoucheli-Baudot, N
    INTERNATIONAL ANGIOLOGY, 2004, 23 (03) : 255 - 258