Screen-film mammography and soft-copy full-field digital mammography: Comparison in the patients with microcalcifications

被引:18
作者
Kim, HS
Han, BK
Choo, KS
Jeon, YH
Kim, JH
Choe, YH
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Surg, Seoul 135710, South Korea
关键词
radiography; digital; mammography; microcalcification; screens and films; breast radiography; soft copy reading;
D O I
10.3348/kjr.2005.6.4.214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We wanted to compare the ability of screen-film mammography (SFM) and soft-copy full-field digital mammography (s-FFDM) on two different monitors to detect and characterize microcalcifications. Materials and Methods: The images of 40 patients with microcalcifications (three patients had malignant lesion and 37 patients had benign lesion), who underwent both SFM and FFDM at an interval of less than six months, were independently evaluated by three readers. Three reading sessions were undertaken for SFM and for FFDM on a mammography-dedicated review workstation (RWS, 2K x 2.5K), and for FFDM on a high-resolution PACS monitor (1.7K x 2.3K). The image quality, breast composition and the number and conspicuity of the microcalcifications were evaluated using a three-point rating method, and the mammographic assessment was classified into 4 categories (normal, benign, low concern and moderate to great concern). Results: The image quality, the number and conspicuity of the microcalcifications by s-FFDM (on the RWS, PACS and both) were superior to those by SFM in 80.0% and 52.5% of the cases, respectively (p < 0.01), and those by the 85.0%, s-FFDM on the two different monitors were similar in 15.0%,12.5% and 35.0% of the cases, respectively (p > 0.01). The mammographic assessment category for the microcalcifications in the three reading sessions was similar. Conclusion: s-FFDM gives a superior image quality to SFM and it is better at evaluating microcalcifications. In addition, s-FFDM with the PACS monitor is comparable to s-FFDM with the RWS for evaluating microcalcifications.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 17 条
[1]  
[Anonymous], BREAST IM REP DAT SY
[2]  
Brown H, 1999, APPL MIXED MODELS ME, P199
[3]  
FEIG SA, 1995, RADIOL CLIN N AM, V33, P1205
[4]   Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography [J].
Fischer, U ;
Baum, F ;
Obenauer, S ;
Luftner-Nagel, S ;
von Heyden, D ;
Vosshenrich, R ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2679-2683
[5]   A magnification mammography technique using storage phosphor plates: Experimental investigations concerning spatial resolution and detection of microcalcifications. [J].
Funke, M ;
Hermann, KP ;
Breiter, N ;
HundertMark, C ;
Sachs, J ;
Gruhl, T ;
Sperner, W ;
Grabbe, E .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (02) :174-179
[6]   Filmless in 60 days: The impact of picture archiving and communications systems within a large urban hospital [J].
Hayt, DB ;
Alexander, S ;
Drakakis, J ;
Berdebes, N .
JOURNAL OF DIGITAL IMAGING, 2001, 14 (02) :62-71
[7]   Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography. [J].
Hermann, KP ;
Obenauer, S ;
Grabbe, E .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11) :940-945
[8]   Digital mammography in direct magnification technique using a large-area amorphous silicon X-ray detector. [J].
Hermann, KP ;
Hundertmark, C ;
Funke, M ;
von Brenndorff, A ;
Grabbe, E .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05) :503-506
[9]   The current status of digital mammography [J].
James, JJ .
CLINICAL RADIOLOGY, 2004, 59 (01) :1-10
[10]   Storage phosphor and film-screen mammography:: performance with different mammographic techniques [J].
Kheddache, S ;
Thilander-Klang, A ;
Lanhede, B ;
Månsson, LG ;
Bjurstam, N ;
Ackerholm, P ;
Björneld, L .
EUROPEAN RADIOLOGY, 1999, 9 (04) :591-597