Esophageal and pharyngeal injuries associated with the use of the esophageal-tracheal Combitube®

被引:0
作者
Stoppacher, R [1 ]
Teggatz, JR [1 ]
Jentzen, JM [1 ]
机构
[1] Milwaukee Cty Med Examiners Off, Milwaukee, WI 53233 USA
关键词
forensic science; Combitube((R)); esophagus; injury;
D O I
暂无
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The Combitube(R) is a ventilatory device consisting of a twin lumen tube with proximal and distal inflatable cuffs. The major benefit of the Combitube(R) is that its design and function allow for ventilation through non-laryngoscope-assisted insertion into either the trachea, oresophagus. As with any invasive procedure, intubation using the Combitube(R) carries certain risks and potential complications. The majority of complications are relatively minor; however, a rare and serious complication reported primarily in the anesthesiology literature is laceration of the esophagus. This reportedly rare injury is increasingly seen by medical examiners/coroners in the forensic setting. This paper presents a series of three cases of esophageal laceration and a single case of perforation of the hypopharynx associated with the use of the Combitube(R). while also exploring potential mechanisms of injury. In addition, this work demonstrates the vital role the medical examiner/coroner plays in identifying existing or potential problems with current or emerging medical devices.
引用
收藏
页码:586 / 591
页数:6
相关论文
共 12 条
  • [1] Current status of the Combitube™:: A review of the literature
    Agro, F
    Frass, M
    Benumof, JL
    Krafft, P
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (04) : 307 - 314
  • [2] DONMICHAEL TA, 1968, LANCET, V2, P1329
  • [3] THE ESOPHAGEAL TRACHEAL COMBITUBE - PRELIMINARY-RESULTS WITH A NEW AIRWAY FOR CPR
    FRASS, M
    FRENZER, R
    ZDRAHAL, F
    HOFLEHNER, G
    PORGES, P
    LACKNER, F
    [J]. ANNALS OF EMERGENCY MEDICINE, 1987, 16 (07) : 768 - 772
  • [4] ESOPHAGEAL-PERFORATION FOLLOWING USE OF THE ESOPHAGEAL OBTURATOR AIRWAY
    HARRISON, EE
    NORD, HJ
    BEEMAN, RW
    [J]. ANNALS OF EMERGENCY MEDICINE, 1980, 9 (01) : 21 - 25
  • [5] The influence of cuff volume and anatomic location on pharyngeal esophageal, and tracheal mucosal pressures with the esophageal tracheal combitube
    Keller, C
    Brimacombe, J
    Boehler, M
    Loeckinger, A
    Puehringer, F
    [J]. ANESTHESIOLOGY, 2002, 96 (05) : 1074 - 1077
  • [6] Esophageal rupture associated with the use of the Combitube(TM)
    Klein, H
    Williamson, M
    SueLing, HM
    Vucevic, M
    Quinn, AC
    [J]. ANESTHESIA AND ANALGESIA, 1997, 85 (04) : 937 - 939
  • [7] Complications following the use of the Combitube, tracheal tube and laryngeal mask airway
    Oczenski, W
    Krenn, H
    Dahaba, AA
    Binder, M
    El-Schahawi-Kienzl, I
    Kohout, S
    Schwarz, S
    Fitzgerald, RD
    [J]. ANAESTHESIA, 1999, 54 (12) : 1161 - 1165
  • [8] Richards Christopher F., 1998, Journal of Emergency Medicine, V16, P37, DOI 10.1016/S0736-4679(97)00239-4
  • [9] SILVIS SE, 1976, JAMA-J AM MED ASSOC, V235, P923
  • [10] *TYC HEALTHC, 1998, COMB PACK INS