Identification of Capacitive MEMS Accelerometer Structure Parameters for Human Body Dynamics Measurements

被引:18
作者
Benevicius, Vincas [1 ]
Ostasevicius, Vytautas [1 ]
Gaidys, Rimvydas [1 ]
机构
[1] Kaunas Univ Technol, Inst Hitech Dev, Fac Mech Engn & Mechatron, LT-51369 Kaunas, Lithuania
关键词
capacitive; accelerometer; MEMS; optimization; proof-mass; L-shaped beam; OPTIMIZATION METHODOLOGY;
D O I
10.3390/s130911184
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to their small size, low weight, low cost and low energy consumption, MEMS accelerometers have achieved great commercial success in recent decades. The aim of this research work is to identify a MEMS accelerometer structure for human body dynamics measurements. Photogrammetry was used in order to measure possible maximum accelerations of human body parts and the bandwidth of the digital acceleration signal. As the primary structure the capacitive accelerometer configuration is chosen in such a way that sensing part measures on all three axes as it is 3D accelerometer and sensitivity on each axis is equal. Hill climbing optimization was used to find the structure parameters. Proof-mass displacements were simulated for all the acceleration range that was given by the optimization problem constraints. The final model was constructed in Comsol Multiphysics. Eigenfrequencies were calculated and model's response was found, when vibration stand displacement data was fed into the model as the base excitation law. Model output comparison with experimental data was conducted for all excitation frequencies used during the experiments.
引用
收藏
页码:11184 / 11195
页数:12
相关论文
共 16 条
  • [1] Ananthasures GK, 2003, OPTIMAL SYNTHESIS ME, P150
  • [2] Human body rheology impact on measurements in accelerometer applications
    Benevicius, V.
    Ostasevicius, V.
    Gaidys, R.
    [J]. MECHANIKA, 2013, (01): : 40 - 45
  • [3] Design of a compact system using a MEMS accelerometer to measure body posture and ambulation
    Bliley, Kara E.
    Schwab, Daniel J.
    Holmes, David R., III
    Kane, Paul H.
    Levine, James A.
    Daniel, Erik S.
    Gilbert, Barry K.
    [J]. 19TH IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2006, : 335 - +
  • [4] A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    Bouten, CVC
    Koekkoek, KTM
    Verduin, M
    Kodde, R
    Janssen, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 136 - 147
  • [5] Fundamentals of videogrammetry - A review
    Gruen, A
    [J]. HUMAN MOVEMENT SCIENCE, 1997, 16 (2-3) : 155 - 187
  • [6] Acceleration of the calcaneus at heel strike in neutrally aligned and pes planus feet
    Ledoux, WR
    Hillstrom, HJ
    [J]. CLINICAL BIOMECHANICS, 2001, 16 (07) : 608 - 613
  • [7] Lee H, 2009, LECT NOTES COMPUT SC, V5801, P148
  • [8] Automated optimal synthesis of microaccelerometers
    Mukherjee, T
    Zhou, Y
    Fedder, GK
    [J]. MEMS '99: TWELFTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 1999, : 326 - 331
  • [9] Numerical Analysis of Dynamic Effects of a Nonlinear Vibro-Impact Process for Enhancing the Reliability of Contact-Type MEMS Devices
    Ostasevicius, Vytautas
    Gaidys, Rimvydas
    Dauksevicius, Rolanas
    [J]. SENSORS, 2009, 9 (12) : 10201 - 10216
  • [10] On the optimization of compliant force amplifier mechanisms for surface micromachined resonant accelerometers
    Pedersen, CBW
    Seshia, AA
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (10) : 1281 - 1293