Increasing the lateral resolution of 4Pi fluorescence microscopes

被引:18
作者
Sandeau, N [1 ]
Giovannini, H [1 ]
机构
[1] Univ Paul Cezanne EGIM Nord, CNRS, UMR 6133, Inst Fresnel, F-13397 Marseille 20, France
关键词
D O I
10.1364/JOSAA.23.001089
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The axial resolution of fluorescence microscopes can be considerably improved by superposing two illumination beams and by adding coherently the two wavefronts emitted by the luminescent sample. This solution has been implemented in 4Pi microscopes. Theoretical and experimental results have shown that a considerable improvement of the axial resolution can be obtained with these microscopes. However, the lateral resolution remains limited by diffraction. We propose a configuration of a Vi microscope in which the lateral displacement of the source modifies the collection efficiency function (CEF). Numerical calculations based on an approximate scalar theory and on exact vector-wave-optics results of the field distribution of the electromagnetic field in image space show that the lateral extent of the CEF can be reduced by a factor greater than 2 with respect to the diffraction limit. We show that, with this solution, the resolution in the transverse plane of 4Pi type B and 4Pi type C microscopes can be improved significantly. (C) 2006 Optical Society of America.
引用
收藏
页码:1089 / 1095
页数:7
相关论文
共 19 条
[1]   Single sharp spot in fluorescence microscopy of two opposing lenses [J].
Blanca, CM ;
Bewersdorf, J ;
Hell, SW .
APPLIED PHYSICS LETTERS, 2001, 79 (15) :2321-2323
[2]   Orientation imaging of single molecules by wide-field epifluorescence microscopy [J].
Böhmer, M ;
Enderlein, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2003, 20 (03) :554-559
[3]   Focal spots of size λ/23 open up far-field florescence microscopy at 33 nm axial resolution -: art. no. 163901 [J].
Dyba, M ;
Hell, SW .
PHYSICAL REVIEW LETTERS, 2002, 88 (16) :4-163901
[4]   Theoretical study of detection of a dipole emitter through an objective with high numerical aperture [J].
Enderlein, J .
OPTICS LETTERS, 2000, 25 (09) :634-636
[5]   3-DIMENSIONAL TRANSFER-FUNCTIONS IN 4PI CONFOCAL MICROSCOPES [J].
GU, M ;
SHEPPARD, CJR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (05) :1619-1627
[6]   Cooperative 4Pi excitation and detection yields sevenfold sharper optical sections in live-cell microscopy [J].
Gugel, H ;
Bewersdorf, J ;
Jakobs, S ;
Engelhardt, J ;
Storz, R ;
Hell, SW .
BIOPHYSICAL JOURNAL, 2004, 87 (06) :4146-4152
[7]   Focusing of light through a stratified medium:: a practical approach for computing microscope point spread functions.: Part I:: Conventional microscopy [J].
Haeberlé, O .
OPTICS COMMUNICATIONS, 2003, 216 (1-3) :55-63
[8]   PROPERTIES OF A 4PI CONFOCAL FLUORESCENCE MICROSCOPE [J].
HELL, S ;
STELZER, EHK .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1992, 9 (12) :2159-2166
[9]  
Hell S. W., 1992, European patent EP, Patent No. 0491289
[10]   MEASUREMENT OF THE 4PI-CONFOCAL POINT-SPREAD FUNCTION PROVES 75 NM AXIAL RESOLUTION [J].
HELL, SW ;
LINDEK, S ;
CREMER, C ;
STELZER, EHK .
APPLIED PHYSICS LETTERS, 1994, 64 (11) :1335-1337