Left Ventricular Assist Device Management in the ICU

被引:35
作者
Pratt, Alexandra K. [1 ]
Shah, Nimesh S. [1 ]
Boyce, Steven W. [2 ]
机构
[1] MedStar Washington Hosp Ctr, Surg Crit Care Serv, Washington, DC USA
[2] MedStar Washington Hosp Ctr, MedStar Heart Inst, Adv Heart Failure Program, Washington, DC USA
关键词
continuous-flow left ventricular assist device; HeartMate II; HeartWare; left ventricular assist device; MECHANICAL CIRCULATORY SUPPORT; INTERMACS ANNUAL-REPORT; ROTARY BLOOD PUMPS; CONTINUOUS-FLOW; HEART-FAILURE; INTERNATIONAL SOCIETY; CLINICAL MANAGEMENT; DESTINATION THERAPY; IMPLANTATION; SPEED;
D O I
10.1097/01.ccm.0000435675.91305.76
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To review left ventricular assist device physiology, initial postoperative management, common complications, trouble shooting and management of hypotension, and other common ICU problems. Data Source: Narrative review of relevant medical literature. Data Synthesis: Left ventricular assist devices prolong the lives of patients with end-stage heart failure, and their use is increasing. Continuous-flow left ventricular assist devices have replaced first-generation pulsatile devices. These patients present unique management concerns. In the immediate postimplant period, care must be taken to support the unassisted right ventricle. Invasive monitors for blood pressure, pulmonary artery catheterization, and echocardiography are essential to optimize left ventricular assist device settings and cardiac performance. Anticoagulation is necessary to prevent devastating thrombotic and embolic complications, but bleeding is a major source of morbidity due to inherent bleeding diatheses and prescribed anticoagulants. Infection of the device can be life threatening, and all infections must be aggressively treated to avoid seeding the device. Patients are at risk of ventricular arrhythmias because of their underlying disease, as well as the placement and position of the inflow cannula. Aortic valve stenosis and insufficiency develop over time and can lead to thrombosis or heart failure. Cardiopulmonary resuscitation with chest compressions must be performed with care or not at all due to risk of dislodging the device. Conclusion: Intensivists are increasingly likely to encounter patients requiring mechanical circulatory support with left ventricular assist devices at various points in the trajectory of their disease, from the immediate postimplant period to subsequent admissions for complications, and at end of life. A basic understanding of left ventricular assist device physiology is essential to the safe and effective care of these patients.
引用
收藏
页码:158 / 168
页数:11
相关论文
共 100 条
  • [1] Use of an Intrapericardial, Continuous-Flow, Centrifugal Pump in Patients Awaiting Heart Transplantation
    Aaronson, Keith D.
    Slaughter, Mark S.
    Miller, Leslie W.
    McGee, Edwin C.
    Cotts, William G.
    Acker, Michael A.
    Jessup, Mariell L.
    Gregoric, Igor D.
    Loyalka, Pranav
    Frazier, O. H.
    Jeevanandam, Valluvan
    Anderson, Allen S.
    Kormos, Robert L.
    Teuteberg, Jeffrey J.
    Levy, Wayne C.
    Naftel, David C.
    Bittman, Richard M.
    Pagani, Francis D.
    Hathaway, David R.
    Boyce, Steven W.
    [J]. CIRCULATION, 2012, 125 (25) : 3191 - +
  • [2] What is the optimum antibiotic prophylaxis in patients undergoing implantation of a left ventricular assist device?
    Acharya, Metesh Nalin
    Som, Robin
    Tsui, Steven
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (02) : 209 - 214
  • [3] HeartWare continuous-flow ventricular assist device thrombosis: The Bad Oeynhausen experience
    Aissaoui, Nadia
    Boergermann, Jochen
    Gummert, Jan
    Morshuis, Michiel
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (04) : E37 - E39
  • [4] Hemodynamic Stress Echocardiography in Patients Supported With a Continuous-Flow Left Ventricular Assist Device
    Andersen, Mads
    Gustafsson, Finn
    Madsen, Per Lav
    Brassard, Patrice
    Jensen, Anette Schophuus
    Secher, Niels
    Hassager, Christian
    Nordsborg, Nikolai
    Moller, Jacob Eifer
    [J]. JACC-CARDIOVASCULAR IMAGING, 2010, 3 (08) : 854 - 859
  • [5] Incidence of Ventricular Arrhythmias in Patients on Long-term Support With a Continuous-flow Assist Device (HeartMate II)
    Andersen, Mads
    Videbaek, Regitze
    Boesgaard, Soren
    Sander, Kare
    Hartsen, Peter B.
    Gustafsson, Finn
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (07) : 733 - 735
  • [6] Liberal use of delayed sternal closure for postcardiotomy hemodynamic instability
    Anderson, CA
    Filsoufi, F
    Aklog, L
    Farivar, RS
    Byrne, JG
    Adams, DH
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (05) : 1484 - 1488
  • [7] [Anonymous], 2010, THOR CORP HEARTM 2 L
  • [8] Technique for Less Invasive Implantation of Heartmate II Left Ventricular Assist Device Without Median Sternotomy
    Anyanwu, Anelechi C.
    [J]. SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2011, 23 (03) : 241 - 244
  • [9] Human pulmonary vascular response to 4 h of hypercapnia and hypocapnia measured using Doppler echo cardiography
    Balanos, GM
    Talbot, NP
    Dorrington, KL
    Robbins, PA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2003, 94 (04) : 1543 - 1551
  • [10] Case series: Clinical management of persistent mechanical assist device driveline drainage using vacuum-assisted closure therapy
    Baradarian, Sam
    Stahovich, Marcia
    Krause, Susan
    Adamson, Robert
    Dembitsky, Walter