Influential Parameters in Lightning Current Passing a Grounding System of High Voltage Substation

被引:0
|
作者
Chuong Ho Van Nhat [1 ]
Sang Trinh Minh [2 ]
机构
[1] Ho Chi Minh City Univ Technol, Fac Elect & Elect Engn, Ho Chi Minh City, Vietnam
[2] Univ Techl Education HCMC, Fac Elect & Elect Engn, Ho Chi Minh City, Vietnam
关键词
Grounding System; High Voltage Substation; Grounding Wire; Electric Pole-Grounding Wire System;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The voltage amplitude and its distribution along the grounding grid are decided by current injecting a grounding system of high voltage substation [1]-[2]. Therefore, the short circuit current passing this grounding system of substation is always cared by the designers. [8]-[9] introduced a new method to calculate the current passing grounding system of high voltage substation when lightning strikes on the grounding wire of transmission line at any point regardless of the influential parameters. This paper studied clearly the influence of the parameters of "grounding wire-electric pole system" and from this, the dangerous zone of high voltage substation and some other interesting results were received.
引用
收藏
页码:627 / 632
页数:6
相关论文
共 50 条
  • [1] LIGHTNING CURRENT FLOW APPROXIMATION IN THE HIGH VOLTAGE SUBSTATION MEASUREMENT AREA
    Wiater, Jaroslaw
    18TH INTERNATIONAL CONFERENCE ELECTROMAGNETIC DISTURBANCES EMD 2008, VOL 2, PROCEEDINGS, 2008, : 45 - 47
  • [2] Design of Grounding System of Fuzhou Ultra-High Voltage Substation
    Lin, Zhihe
    Liu, Hanbo
    Zhang, Bin
    Ma, Weihua
    Zou, Jiayong
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2014, 5 : 895 - +
  • [3] Reduction of the fault current passing through the grounding system of an HV substation supplied by cable line
    Popovic, Ljubivoje M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 99 : 493 - 499
  • [4] The Influence of the Grounding Device Structure of a Substation on the Voltage of Conducted Interference of Lightning Currents
    Kosyakov A.A.
    Kuleshov P.V.
    Pogudin A.L.
    Russian Electrical Engineering, 2019, 90 (11): : 752 - 755
  • [5] A simplified approach to calculate the earth fault current division factor passing through the substation grounding system
    Saeednia, Hossein
    Ramezani, Nabiollah
    SCIENTIA IRANICA, 2024, 31 (17) : 1479 - 1489
  • [6] Decreasing lightning shock hazard at the HV substation by the modification of the grounding system
    Sowa, A
    Wiater, J
    2004 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SYMPOSIUM RECORD 1-3, 2004, : 458 - 461
  • [7] Lightning Protection System for High Voltage Transmission Line in Area with High Grounding Resistance
    Malelak, Monalisa A.
    Zoro, Reynaldo
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 350 - 355
  • [8] Parameters Measurement for Grounding Grids of a 1000kV Ultra-High-Voltage Substation
    Si Wen-Rong
    Fu Chen-Zhao
    Lu Bing -Bing
    Guo Xiang
    Xu Zhi-Bing
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 3688 - 3690
  • [9] Lightning Performance of an Air Insulated High Voltage Substation
    Christodoulou, C. A.
    Vita, V.
    Ekonomou, L.
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 1471 - 1481
  • [10] Lightning Protection System on Substation Extra High Voltage 500 kV Sumatera, Indonesia
    Irsal, Abdurrauf
    Denov, Bryan
    Zoro, Reynaldo
    PROCEEDING OF 2019 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICEEI), 2019, : 672 - 677