Severe prosthesis-patient mismatch after aortic valve replacement for aortic stenosis: Analysis of risk factors for early and long-term mortality

被引:21
作者
Mannacio, Vito [1 ]
Mannacio, Luigi [1 ]
Mango, Emilo [2 ]
Antignano, Anita [3 ]
Mottola, Michele [1 ]
Caparrotti, Sergio [2 ]
Musumeci, Francesco [4 ]
Vosa, Carlo [1 ]
机构
[1] Univ Naples Federico II, Dept Cardiac Surg, Naples, Italy
[2] Casa Cura Montevergine, Cardiac Surg Unit, Mercogliano, Italy
[3] Azienda Osped Santobono Pausillipon, Dept Cardiol, Naples, Italy
[4] Azienda Osped S Camillo Forlanini, Dept Cardiac Surg, Rome, Italy
关键词
Severe prosthesis-patient mismatch; Moderate prosthesis-patient mismatch; Aortic stenosis; Aortic valve replacement; IMPACT; SURVIVAL; SOCIETY; ASSOCIATION; UPDATE;
D O I
10.1016/j.jjcc.2016.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Severe prosthesis-patient mismatch (PPM) is considered to further decrease survival compared to moderate PPM. This study aimed to assess the impact of severe PPM on survival after aortic valve replacement (AVR). Methods: We retrospectively studied 2404 consecutive patients with PPM who underwent first-time AVR for pure stenosis between January 2003 and December 2014. Mismatch was moderate for indexed effective valve orifice >0.65 to <0.85 cm(2)/m(2) and severe for indexed effective valve orifice <0.65 cm(2)/m(2). Moderate mismatch occurred in 2165 patients (89%), and severe in 239 (11%) patients. Logistic multiple regression with bootstrapping and propensity score analyses were performed using 29 clinical and demographic data to assess the risk-adjusted impact of severe mismatch on mortality. The Cox proportional hazards model was constructed to process the long-term outcome. Results: Early mortality was 2.3% (51/2165) in moderate mismatch group and 3.7% (9/239) in severe mismatch group (p = 0.2). Mortality at 5 and 10 years, was 218/1470 (14.8%) and 252/585 (43.1%) for moderate mismatch and 43/198 (21.7%) and 61/105 (58.1%) for severe mismatch (p = 0.02 and p = 0.006). Multivariable predictors of late mortality were as follows: age >= 70 years, left ventricular ejection fraction <= 40%, indexed left ventricular mass >220 g/m(2) and concomitant coronary artery revascularization. After propensity score matching, conditional logistic regression analysis demonstrated no relationship between severe mismatch and increased mortality at 5 postoperative years (HR, 0.9; 95% CI, 0.7-1.6; p = 0.06), whereas it was significant at 10 postoperative years (HR, 1.9; 95% CI, 1.2-2.5; p = 0.03). During the follow-up, severe mismatch was associated with more frequent hospital readmissions for cardiac events (0.12 vs. 0.08 events/patient/year, p = 0.007). Conclusions: Patients with severe mismatch had lower long-term survival and higher incidence of hospital readmissions for cardiac events. However, the effect of severe mismatch on outcome appeared mainly related to the preoperative risk profile of each patient. (C) 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 23 条
[1]   Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement [J].
Bakhtiary, Farhad ;
Schiemann, Mirko ;
Dzemali, Omer ;
Dogan, Selami ;
Schaechinger, Volker ;
Ackermann, Hans ;
Moritz, Anton ;
Kleine, Peter .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (07) :790-796
[2]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[3]   Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement [J].
Bleiziffer, Sabine ;
Ali, Ayyaz ;
Hettich, Ina M. ;
Akdere, Deniz ;
Laubender, Ruediger P. ;
Ruzicka, Daniel ;
Boehm, Johannes ;
Lange, Ruediger ;
Eichinger, Walter .
HEART, 2010, 96 (11) :865-871
[4]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.jacc.2008.02.032, 10.1016/j.jacc.2008.05.007, 10.1016/j.hrthm.2008.04.014]
[5]   Valve Prosthesis-Patient Mismatch (VP-PM) A Long-Term Perspective [J].
Daneshvar, Samuel A. ;
Rahimtoola, Shahbudin H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (13) :1123-1135
[6]   Prosthesis-patient mismatch: An update [J].
Dumesnil J.G. ;
Pibarot P. .
Current Cardiology Reports, 2011, 13 (3) :250-257
[7]   VALIDATION AND APPLICATIONS OF INDEXED AORTIC PROSTHETIC VALVE AREAS CALCULATED BY DOPPLER ECHOCARDIOGRAPHY [J].
DUMESNIL, JG ;
HONOS, GN ;
LEMIEUX, M ;
BEAUCHEMIN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :637-643
[8]   Impact of valve prosthesis-patient mismatch estimated by echocardiographic-determined effective orifice area on long-term outcome after aortic valve replacement [J].
Florath, Ines ;
Albert, Alexander ;
Rosendahl, Utrich ;
Ennker, Ina Carolin ;
Ennker, Juergen .
AMERICAN HEART JOURNAL, 2008, 155 (06) :1135-1142
[9]   Patient prosthesis mismatch is rare after aortic valve replacement: Valve size may be irrelevant - Discussion [J].
Olinger, GN ;
Christakis, GT .
ANNALS OF THORACIC SURGERY, 2002, 73 (06) :1829-1829
[10]   Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival [J].
Howell, Neil J. ;
Keogh, Bruce E. ;
Ray, Daniel ;
Bonser, Robert S. ;
Graham, Tim R. ;
Mascaro, Jorge ;
Rooney, Stephen J. ;
Wilson, Ian C. ;
Pagano, Domenico .
ANNALS OF THORACIC SURGERY, 2010, 89 (01) :60-64