Thermal-Hydraulic Analysis of the DEMO CS Coil

被引:18
|
作者
Dembkowska, Aleksandra [1 ]
Lewandowska, Monika [1 ]
Sarasola, Xabier [2 ]
机构
[1] West Pomeranian Univ Technol, PL-70310 Szczecin, Poland
[2] EPFL, Paul Scherrer Inst, SPC, CH-5232 Villigen, Switzerland
关键词
DEMO CS coil; CS1; module; thermal-hydraulic analysis; temperature margin; DESIGN; SUPERCONDUCTORS; CABLES;
D O I
10.1109/TASC.2018.2809425
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two alternative designs of the central solenoid (CS) coil were proposed by EPFL-SPC PSI Villigen and CEA Cadarache for the European DEMO Tokamak. The DEMO CS coil consists of five modules, namely CSU3, CSU2, CS1, CSL2, and CSL3, the most demanding of which is the CS1. According to the EPFL-SCP design, the CS1 winding pack is composed of ten subcoils, each consisting of two layers wound with cables of the same kind. Our present work is focused on the thermal-hydraulic analysis of the CS1 cables designed by EPFL-SPC at the normal operating conditions during the whole current cycle. We took into account the realistic magnetic field distribution, heat transfer between neighboring turns, and heat generation due to AC losses. The analysis, performed using the THEA CryoSoft code, was aimed at the assessment of the minimum temperature margin and at verification if the proposed design fulfills the acceptance criterion. For the considered current scenario, the minimum of the temperature margin was observed at the end of the dwell phase. The temperature margin in the subcoils 1-9 was above the 1.5 K criterion, but was slightly too small in the most outer subcoil 10.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Thermal-hydraulic analysis of the DEMO CS coil designed by CEA
    Dembkowska, Aleksandra
    Lewandowska, Monika
    Zani, Louis
    Lacroix, Benoit
    FUSION ENGINEERING AND DESIGN, 2021, 171
  • [2] Thermal-hydraulic analysis of an HTS DEMO TF coil
    Lewandowska, Monika
    Dembkowska, Aleksandra
    Heller, Reinhard
    Wolf, Michael
    Cryogenics, 2018, 96 : 125 - 132
  • [3] Thermal-hydraulic analysis of the upgraded EU-DEMO CS1 coil
    Dembkowska, Aleksandra
    Lewandowska, Monika
    Sarasola, Xabier
    SUPERCONDUCTIVITY AND PARTICLE ACCELERATORS 2018, 2019, 11054
  • [4] Thermal-hydraulic analysis of an HTS DEMO TF coil
    Lewandowska, Monika
    Dembkowska, Aleksandra
    Heller, Reinhard
    Wolf, Michael
    CRYOGENICS, 2018, 96 : 125 - 132
  • [5] Thermal-Hydraulic Analysis of LTS Cables for the DEMO TF Coil
    Lewandowska, Monika
    Sedlak, Kamil
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)
  • [6] Development of a Thermal-Hydraulic Model for the European DEMO TF Coil
    Zanino, Roberto
    Bonifetto, Roberto
    Dicuonzo, Ortensia
    Muzzi, Luigi
    Nallo, Giuseppe F.
    Savoldi, Laura
    Turtu, Simonetta
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
  • [7] Thermal-hydraulic analysis of the HCLL DEMO blanket
    Aiello, G.
    Gabriel, F.
    Giancarli, L.
    Rampal, G.
    Salavy, J. -F.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (15-24) : 2189 - 2194
  • [8] Thermal-hydraulic analysis of LTS cables for the DEMO TF coil using simplified models
    Lewandowska, Monika
    Dembkowska, Aleksandra
    NUKLEONIKA, 2017, 62 (01) : 23 - 28
  • [9] Thermal-hydraulic analysis of the DTT CS and PF pulsed coil performance during AC operation
    Bonifetto, R.
    Di Zenobio, A.
    Muzzi, L.
    Turtu, S.
    Zanino, R.
    Zappatore, A.
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [10] Thermal-hydraulic analysis of the DEMO PF coils designed by CEA
    Lewandowska, Monika
    Dembkowska, Aleksandra
    Zani, Louis
    Lacroix, Benoit
    CRYOGENICS, 2022, 127