Trace analysis of contraceptive drug levonorgestrel in wastewater samples by a newly developed indirect competitive enzyme-linked immunosorbent assay (ELISA) coupled with solid phase extraction

被引:46
|
作者
Pu, Chun [1 ]
Wu, Ya-Fei [1 ]
Yang, Hong [2 ]
Deng, An-Ping [1 ]
机构
[1] Sichuan Univ, Coll Chem, Chengdu 610064, Peoples R China
[2] Sichuan Univ, W China Sch Pharm, Chengdu 610041, Peoples R China
基金
中国国家自然科学基金;
关键词
Levonorgestrel; Enzyme-linked immunosorbent assay; Steroids; Progestogens; Wastewater sample;
D O I
10.1016/j.aca.2008.08.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and specific enzyme-linked immunosorbent assay for the detection of levonorgestrel (LNG) in wastewater samples was developed. The carbonyl group at position 3 on LNG molecule was reduced to hydroxyl group, which was then linked to ethyl bromoacetate. After hydrolysis, the LNG derivative with carboxylic group at the end of a spacer arm was obtained and covalently coupled to carrier proteins. The conjugates of LNG-bovine serum albumin and LNG-ovalbumin were used as immunogen and coating antigen, respectively The superior polyclonal antibody was characterized in terms of sensitivity and specificity. The ELISA standard curve for LNG was constructed in the concentration range of 0.1-100 ng mL(-1). For eight standard curves run in 4 weeks, IC50 values were found within 0.9 +/- 0.2 ng mL(-1) and the limit of detection was about 0.07 ng mL(-1). The antiserum displayed 19.6% cross-reactivity with 17 alpha-ethynylestradiol, but only lesser than 0.1% cross-reactivity with other seven tested compounds. The parameters of the assay demonstrate the high sensitivity, specificity and stability of the established ELISA. Recoveries of LNG in spiked water samples were found in range of 95.0-123.5% with the relative standard deviations of 5.3-11.5%. Coupled with solid phase extraction, the ELISA was applied for the determination of LNG in influent and effluent obtained from wastewater treatment plant and the results were confirmed by HPLC. The results measured by ELISA were very similar to those of HPLC. The proposed ELISA provides an alternative method for the determination of trace LNG in wastewater samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 2 条
  • [1] Development of a New Monoclonal Antibody against Brevetoxins in Oyster Samples Based on the Indirect Competitive Enzyme-Linked Immunosorbent Assay
    Zhang, Xiya
    Ding, Mingyue
    Zhang, Chensi
    Mao, Yexuan
    Wang, Youyi
    Li, Peipei
    Jiang, Haiyang
    Wang, Zhanhui
    Yu, Xuezhi
    FOODS, 2021, 10 (10)
  • [2] Development of polyclonal antibody-based indirect competitive enzyme-linked immunosorbent assay for sodium saccharin residue in food samples
    Wang, Yu
    Xu, Zhen-Lin
    Xie, Yan-Yun
    Tian, Yuan-Xin
    Shen, Yu-Dong
    Young, Glenn M.
    Wang, Hong
    Lei, Hoing-Tao
    Sun, Yuan-Ming
    FOOD CHEMISTRY, 2011, 126 (02) : 815 - 820