External fixation design evolution enhances biomechanical frame performance

被引:14
作者
Sellei, Richard Martin [1 ,2 ]
Kobbe, Philipp [1 ,3 ]
Dadgar, Azad [1 ,3 ]
Pfeifer, Roman [1 ,3 ]
Behrens, Markus [4 ]
von Oldenburg, Geert [5 ]
Pape, Hans-Christoph [1 ,3 ]
机构
[1] Univ Aachen, Med Ctr, Harald Tscherne Res Lab Orthopaed Trauma, D-52074 Aachen, Germany
[2] Sana Klinikum Offenbach, Dept Orthopaed Trauma, D-63069 Offenbach, Germany
[3] Univ Aachen, Med Ctr, Dept Orthopaed Trauma, D-52074 Aachen, Germany
[4] Stryker Trauma & Extrem, CH-2545 Selzach, Switzerland
[5] Stryker Trauma & Extrem, D-24232 Kiel, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷
关键词
Hoffmann; 3; External fixation system; Stiffness; Double stacking; STIFFNESS; FIXATORS;
D O I
10.1016/S0020-1383(15)30007-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: External fixation has become a quick and easy application for fracture stabilisation of the extremities and/or pelvis to maintain the reduction and provide stability while sparing the soft tissues. Over the last years, enhanced construct stiffness has become an essential requirement to preserve fracture reduction, particularly in active and overweight patients. This study was performed to determine whether the advancement of design features enhances the external fixation construct stiffness. The stiffness of the recently developed Hoffmann 3 external fixation system was determined and its characteristics compared with the widely clinically accepted Hoffmann II MRI fixation system. Methods: A synthetic fracture model was used. Two carbon tubes with a fracture gap of 20 mm were appropriate to determine the stiffness of three different configurations: the basic frame configuration (group H 3, representing Hoffmann 3 with a rod diameter of 11 mm) using a double rod construction with 6 mm Apex pins, was compared with the Hoffmann II MRI fixation system using two 8.0 mm diameter rods with 6 mm (group H II-6 mm) and 5 mm (group H II-5 mm) Apex pins. Each group was tested five times under anterior-posterior bending (N/mm), medio-lateral bending (N/mm) and axial torsion loading directions (Nm/deg). The stiffness results of each construct were compared statistically. Results: The basic frame construct (group H 3) showed consistently higher stiffness properties compared with the other configurations. The anterior-posterior-bending loads resulted in a mean value of 31 N/mm, which was significantly higher compared with the other groups (p=0.008) at 16 N/mm. The medio-lateral-bending test revealed a mean stiffness of 59 N/mm in the H3 group, compared with 43 N/mm in the H II-6 group and 31 N/mm in the H II-5 group. The axial torsion measurements of the Hoffmann 3 group yielded significantly higher results (1.03 Nm/degrees) compared with group H II-6 (0.61 Nm/degrees) and group H II-5 (0.56 Nm/degrees). Conclusions: The Hoffmann 3 construct showed the highest stiffness properties under bending and torsion loads. The enhanced stiffness of the Hoffmann 3 device may be helpful in maintaining fracture reduction and soft tissue compromise. This investigation showed the advancement of Hoffmann design features may be effective in enhancing frame stiffness. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S23 / S26
页数:4
相关论文
共 13 条
[1]  
ASTM International, 2007, STAND SPEC TEST METH, P1
[2]   The stiffness characteristics of hybrid Ilizarov fixators [J].
Baran, Onder ;
Havitcioglu, Hasan ;
Tatari, Hasan ;
Cecen, Berivan .
JOURNAL OF BIOMECHANICS, 2008, 41 (14) :2960-2963
[3]  
BEHRENS F, 1989, CLIN ORTHOP RELAT R, P48
[4]  
BEHRENS F, 1983, CLIN ORTHOP RELAT R, P103
[5]   EXTERNAL FIXATION OF THE TIBIA - BASIC CONCEPTS AND PROSPECTIVE EVALUATION [J].
BEHRENS, F ;
SEARLS, K .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (02) :246-254
[6]  
CHAO EYS, 1989, CLIN ORTHOP RELAT R, P24
[7]  
Moss DP, 2007, BULL HOSP JT DIS, V65, P294
[8]  
Pape Hans-Christoph, 2005, J Orthop Trauma, V19, P551, DOI 10.1097/01.bot.0000161712.87129.80
[9]   Timing of Fracture Fixation in Multitrauma Patients: The Role of Early Total Care and Damage Control Surgery [J].
Pape, Hans-Christoph ;
Tornetta, Paul, III ;
Tarkin, Ivan ;
Tzioupis, Christopher ;
Sabeson, Van ;
Olson, Steven A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (09) :541-549
[10]   The timing of definitive fixation for major fractures in polytrauma-A matched-pair comparison between a US and European level I centres: Analysis of current fracture management practice in polytrauma [J].
Schreiber, Verena M. ;
Tarkin, Ivan S. ;
Hildebrand, Frank ;
Darwiche, Sophie ;
Pfeifer, Roman ;
Chelly, Jaques ;
Giannoudis, Peter ;
Pape, Hans-Christoph .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (07) :650-654