共 50 条
DETERMINATION OF LIQUID-LIQUID EQUILIBRIUM DATA FOR BIODIESEL CONTAINING TERNARY SYSTEMS USING NEAR INFRARED TECHNIQUE
被引:4
|作者:
Beneti, S. C.
[1
]
Priamo, W. L.
[2
]
Lanza, M.
[3
]
Kunita, M. H.
[4
]
Mazutti, M. A.
[5
]
Cardozo Filho, L.
[4
]
Vladimir Oliveira, J.
[1
]
机构:
[1] Univ Reg Integrada Alto Uruguai & Missoes, Dept Food Engn, URI, BR-99700000 Erechim, RS, Brazil
[2] IFRS, Inst Fed Educ Ciencia & Tecnol Rio Grande Sul, Sertao, RS, Brazil
[3] Univ Fed Santa Catarina, Ctr Technol, Dept Chem Engn & Food Engn, BR-88040900 Florianopolis, SC, Brazil
[4] Univ Estadual Maringa, Dept Chem Engn, Maringa, PR, Brazil
[5] Univ Fed Santa Maria, Dept Chem Engn, BR-97119900 Santa Maria, RS, Brazil
关键词:
Liquid-liquid equilibrium;
Near infrared spectroscopy;
Biodiesel;
Soybean oil;
ANHYDROUS ETHANOL;
NIR;
OIL;
D O I:
10.1590/S0104-66322013000100004
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
This work is focused on the determination of liquid-liquid equilibrium data for systems containing methyl and ethyl fatty acid esters, water, glycerol and ethanol at temperatures of 303.15 K and 318.15 K using a near-infrared spectroscopy technique (NIR). The NIR method used in this investigation provided quite satisfactory results when compared to conventional analytical techniques and hence can be used as an advantageous tool to quantify the compounds involved in the liquid-liquid equilibrium systems: i) without previous preparation of the samples; ii) with less waste generation; iii) at low cost; and iv) via a non-destructive technique, as sample analyses are made directly, showing good reproducibility and reliability of the data. The NIR method was effective in the use of different temperatures for calibration and validation of the systems under study. Besides, it is shown that extrapolation with the technique may be possible, making LLE predictions feasible for other conditions not used in the calibration procedure.
引用
收藏
页码:23 / 31
页数:9
相关论文