Analysis of basic drugs in biological samples using dynamic single-interface hollow fiber liquid-phase microextraction combined with fast electromembrane extraction

被引:29
作者
Rahimi, Atyeh [1 ]
Nojavan, Saeed [1 ]
Maghsoudi, Majid [1 ]
机构
[1] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, GC, Tehran 1983963113, Iran
关键词
Dynamic single-interface; Fast electromembrane extraction; Hollow fiber liquid-phase microextraction; Plasma; Urine; MASS-SPECTROMETRY; IONIC LIQUID; MEMBRANE; CHROMATOGRAPHY; QUANTIFICATION; OPTIMIZATION; AUTOMATION; LIDOCAINE;
D O I
10.1016/j.microc.2020.105001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a combination of single-interface hollow fiber liquid-phase microextraction and electromembrane extraction was applied for the extraction of some basic drugs from biological samples. The extraction process was followed by the HPLC-UV instrument. In this dynamic system, 1-octanol was impregnated into the pores of hollow fiber wall as an acceptor phase, the sample solution (pH = 12.0) was pumped into the lumen of hollow fiber by a syringe pump, the extraction efficiency was improved by filling and emptying (25 times) of sample solution (step-1). The extracted analytes in the organic acceptor phase were back-extracted by a fast electromembrane extraction procedure (step-2). Effective parameters on the extraction efficiency of both methods were investigated and optimized. Under optimized conditions (organic acceptor phase: 1-octanol, sample solution volume: 1500 mu L, flow rate: 2.0 mL min(-1), the number of filling and emptying cycles: 25, voltage: 100 V, back-extraction time: 2 min, and aqueous acceptor phase: 100 mM HCl), the proposed method provided good linearity with determination coefficients ranging from 0.992 to 0.996 over a concentration range of 2.5-1000 ng mL(-)(1). Extraction recoveries were obtained in the range of 65.1 and 88.8%, which resulted in preconcentration factors in the range of 32.6-44.4. The limits of detection were found to be within the range of 0.12-0.36 ng mL(-)(1), while the corresponding repeatability ranged from 3.7 to 9.3% (n = 3). Finally, the optimized method was applied for the quantification of propranolol, diltiazem and, lidocaine in urine and, plasma samples with relative recoveries ranged between 94.1 and 105.4%, indicating the reliability of the method.
引用
收藏
页数:8
相关论文
共 40 条
[1]   Application of polyacrylamide gel as a new membrane in electromembrane extraction for the quantification of basic drugs in breast milk and wastewater samples [J].
Asadi, Sakine ;
Tabani, Hadi ;
Nojavan, Saeed .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 151 :178-185
[2]   Dynamic electromembrane extraction: Automated movement of donor and acceptor phases to improve extraction efficiency [J].
Asl, Yousef Abdossalami ;
Yamini, Yadollah ;
Seidi, Shahram ;
Amanzadeh, Hatam .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1419 :10-18
[3]   A novel approach to automation of dynamic hollow fiber liquid-phase microextraction [J].
Esrafili, Ali ;
Yamini, Yadollah ;
Ghambarian, Mahnaz ;
Moradi, Morteza ;
Seidi, Shahram .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (08) :957-964
[4]  
Gjelstad A., 2013, Scientia Chromatographica, V5, P181, DOI [10.4322/sc.2014.003, DOI 10.4322/sc.2014.003]
[5]   Simulation of flux during electro-membrane extraction based on the Nernst-Planck equation [J].
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) :104-111
[6]   Electrokinetic migration across artificial liquid membranes - Tuning the membrane chemistry to different types of drug substances [J].
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1124 (1-2) :29-34
[7]   Kinetic aspects of hollow fiber liquid-phase microextraction and electromembrane extraction [J].
Gjelstad, Astrid ;
Jensen, Henrik ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
ANALYTICA CHIMICA ACTA, 2012, 742 :10-16
[8]   Electromembrane extraction: a new technique for accelerating bioanalytical sample preparation [J].
Gjelstad, Astrid ;
Pedersen-Bjergaard, Stig .
BIOANALYSIS, 2011, 3 (07) :787-797
[9]   Study of mass transfer in a dynamic hollow-fibre liquid phase microextraction system [J].
Hansson, Helena ;
Colmsjo, Anders ;
Nilsson, Ulrika .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (01) :112-119
[10]   Dynamic hollow-fibre liquid phase microextraction of dinitrophenols from human plasma: Optimization of an extraction flow system using experimental design methodology [J].
Hansson, Helena ;
Lagerstrom, Malene ;
Aberg, Magnus ;
Nilsson, Ulrika .
TALANTA, 2009, 79 (03) :633-638