Rotation Stability of the Cachet Angle-Supported Phakic Intraocular Lens

被引:2
作者
Kermani, Omid [1 ]
Oberheide, Uwe [1 ]
Gerten, Georg [1 ]
机构
[1] Augenklin Neumarkt, D-50667 Cologne, Germany
关键词
OPTICAL COHERENCE TOMOGRAPHY; ANTERIOR SEGMENT; MYOPIA; ACCOMMODATION; IMPLANTATION; EYES;
D O I
10.3928/1081597X-20130515-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the rotational stability of an acrylic angle-supported phakic intraocular lens (PIOL) 12 months after implantation in myopic eyes. METHODS: Patients with a history of moderate to high myopia underwent unilateral or bilateral implantation of an acrylic angle-supported PIOL (AcrySof Cachet; Alcon Laboratories, Inc., Fort Worth, TX). All were followed up for 12 months. IOL rotation was assessed using digital overlay of ocular photographs captured within 2 weeks of implantation and at postoperative month 12. The secondary outcomes of refractive power (spherical equivalent, refractive sphere, and cylinder) and uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were assessed preoperatively and again at 3 months after implantation. RESULTS: Fifty eyes of 28 patients with a mean age of 32 years were included in this retrospective cohort study. All underwent successful IOL implantation and follow-up. A mean 12-month rotation of 11 degrees was observed (standard deviation: 15.1 degrees, range: 0 to 60 degrees). All preoperative measures (mean) of refractive power improved by 3 months postoperatively (spherical equivalent = -0.35 +/- 0.79 diopters [D], spherical refraction = 0.04 +/- 0.82 D, and cylindrical refraction = -0.77 +/- 0.91 D). Two percent of eyes requiring additional laser adjustment by postoperative month 12, primarily due to corneal astigmatism. CONCLUSION: The study findings suggest that AcrySof Cachet angle-supported PIOLs offer moderate 1-year rotational stability. Because this type of IOL also corrects myopia effectively, it appears to be a good treatment option for myopic eyes. However, the rotation that occurs makes it unsuitable for cylinder corrections.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [41] Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens
    Gargallo-Martinez, Beatriz
    Javier Garcia-Medina, Jose
    Rubio-Velazquez, Elena
    Fernandes, Paulo
    Villa-Collar, Cesar
    Gonzalez-Meijome, Jose M.
    Gutierrez-Ortega, Ramon
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [42] Angle-supported intraocular lens versus scleral-sutured posterior chamber intraocular lens in post-cataract surgery aphakic patients: two-year follow-up cost-effectiveness analysis
    Ranno, Stefano
    Rabbiolo, Giovanni Mario
    Lucentini, Stefano
    Ruggiero, Edoardo
    Luccarelli, Saverio Vincenzo
    Lombardi, Linda
    Nucci, Paolo
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (03) : 871 - 879
  • [43] Iris-fixated toric phakic intraocular lens for myopic astigmatism
    Munoz, Gonzalo
    Cardoner, Antoni
    Albarran-Diego, Cesar
    Ferrer-Blasco, Teresa
    Belda-Salmeron, Lurdes
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07) : 1166 - 1175
  • [44] Medium-term visual, refractive, and intraocular stability after implantation of a posterior chamber phakic intraocular lens to correct moderate to high myopia
    Perez-Cambrodi, Rafael J.
    Pinero, David P.
    Madrid-Costa, David
    Blanes-Mompo, Francisco J.
    Ferrer-Blasco, Teresa
    Cervino, Alejandro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10) : 1791 - 1798
  • [45] Cataract surgery following phakic intraocular lens implantation
    Moshirfar, Majid
    Mifflin, Mark
    Wong, Gilbert
    Chang, JoAnn C.
    CURRENT OPINION IN OPHTHALMOLOGY, 2010, 21 (01) : 39 - 44
  • [46] Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens
    Zeng, Zongsheng
    Zhu, Meiyi
    Zhang, Guangbin
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [47] Influence of anterior chamber depth and vault on anterior chamber angle morphology after phakic posterior chamber intraocular lens implantation
    Sanchez-Trancon, Angel
    Manito, Santiago Cerpa
    Sierra, Oscar Torrado
    Baptista, Antonio Manuel
    Serra, Pedro Miguel
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [48] Rotation stability of a toric intraocular lens with a second capsular tension ring
    Sagiv, Oded
    Sachs, Dan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) : 1098 - 1099
  • [49] Visual quality after posterior chamber phakic intraocular lens implantation in keratoconus
    Kurian, Mathew
    Nagappa, Somshekar
    Bhagali, Ridhima
    Shetty, Rohit
    Shetty, Bhujang K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) : 1050 - 1057
  • [50] Comparison of Phakic Intraocular Lens Vault Using Conventional Nomogram and Prediction Formulas
    Ando, Wakako
    Kamiya, Kazutaka
    Hayakawa, Hideki
    Takahashi, Masahide
    Shoji, Nobuyuki
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 8