Rotation Stability of the Cachet Angle-Supported Phakic Intraocular Lens

被引:2
作者
Kermani, Omid [1 ]
Oberheide, Uwe [1 ]
Gerten, Georg [1 ]
机构
[1] Augenklin Neumarkt, D-50667 Cologne, Germany
关键词
OPTICAL COHERENCE TOMOGRAPHY; ANTERIOR SEGMENT; MYOPIA; ACCOMMODATION; IMPLANTATION; EYES;
D O I
10.3928/1081597X-20130515-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the rotational stability of an acrylic angle-supported phakic intraocular lens (PIOL) 12 months after implantation in myopic eyes. METHODS: Patients with a history of moderate to high myopia underwent unilateral or bilateral implantation of an acrylic angle-supported PIOL (AcrySof Cachet; Alcon Laboratories, Inc., Fort Worth, TX). All were followed up for 12 months. IOL rotation was assessed using digital overlay of ocular photographs captured within 2 weeks of implantation and at postoperative month 12. The secondary outcomes of refractive power (spherical equivalent, refractive sphere, and cylinder) and uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were assessed preoperatively and again at 3 months after implantation. RESULTS: Fifty eyes of 28 patients with a mean age of 32 years were included in this retrospective cohort study. All underwent successful IOL implantation and follow-up. A mean 12-month rotation of 11 degrees was observed (standard deviation: 15.1 degrees, range: 0 to 60 degrees). All preoperative measures (mean) of refractive power improved by 3 months postoperatively (spherical equivalent = -0.35 +/- 0.79 diopters [D], spherical refraction = 0.04 +/- 0.82 D, and cylindrical refraction = -0.77 +/- 0.91 D). Two percent of eyes requiring additional laser adjustment by postoperative month 12, primarily due to corneal astigmatism. CONCLUSION: The study findings suggest that AcrySof Cachet angle-supported PIOLs offer moderate 1-year rotational stability. Because this type of IOL also corrects myopia effectively, it appears to be a good treatment option for myopic eyes. However, the rotation that occurs makes it unsuitable for cylinder corrections.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [21] Artisan Phakic Intraocular Lens in Patients With Keratoconus
    Venter, Jan
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (09) : 759 - 764
  • [22] Phakic intraocular lens for the correction of hyperopia
    Koivula, Annemari
    Zetterstrom, Charlotta
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) : 248 - 255
  • [23] Prediction of the trabecular iris angle after posterior chamber phakic intraocular lens implantation
    Nishida, Tomoya
    Kojima, Takashi
    Kataoka, Takahiro
    Isogai, Naoki
    Yoshida, Yoko
    Nakamura, Tomoaki
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (05) : 604 - 610
  • [24] Effect of Angle Opening Parameters on Corneal Endothelial Cell Density and Intraocular Pressure after Posterior Chamber Phakic Intraocular Lens Implantation
    Kamiya, Kazutaka
    Ando, Wakako
    Tsujisawa, Tatsuhiko
    Takahashi, Masahide
    Shoji, Nobuyuki
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (09) : 1 - 10
  • [25] Phakic Intraocular Lens for Keratoconus
    Kato, Naoko
    Toda, Ikuko
    Hori-Komai, Yoshiko
    Sakai, Chikako
    Arai, Hiroyuki
    Tsubota, Kazuo
    OPHTHALMOLOGY, 2011, 118 (03) : 605 - 606
  • [26] Rotational Stability of a New Posterior Chamber Toric Phakic Intraocular Lens
    Yasa, Dilek
    Kose, Bulent
    Agca, Alper
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [27] Iris-fixated phakic intraocular lens explantation
    Duignan, Emma S.
    Quigley, Clare
    Treacy, Maxwell P.
    Eldouri, Azher
    O'Keefe, Michael
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : 988 - 993
  • [28] Refractive lens exchange versus phakic intraocular lenses
    Nanavaty, Mayank A.
    Daya, Sheraz M.
    CURRENT OPINION IN OPHTHALMOLOGY, 2012, 23 (01) : 54 - 61
  • [29] Phakic intraocular lens explantation: series of 175 surgeries
    Marques, Joao Heitor
    Baptista, Pedro Manuel
    Abreu, Ana Carolina
    Monteiro, Silvia
    Pinto, Maria do Ceu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (09) : 1004 - 1009
  • [30] Vague of preoperative phakic intraocular lens simulation using optical coherence tomography
    Doors, Muriel
    Berendschot, Tos T. J. M.
    Hendrikse, Fred
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (03) : 438 - 443