CONCURRENT VALIDITY OF VERTICAL JUMP PERFORMANCE ASSESSMENT SYSTEMS

被引:98
作者
Castagna, Carlo [1 ,2 ]
Ganzetti, Marco [3 ]
Ditroilo, Massimiliano [4 ]
Giovannelli, Marco [2 ]
Rocchetti, Alessandro [3 ]
Manzi, Vincenzo [1 ]
机构
[1] Italian Football Federat FIGC, Tech Dept, Football Training & Biomech Lab, Florence, Italy
[2] Italian Olymp Comm, Marche Reg Sch Sport, Ancona, Italy
[3] Myolab Performance, Jesi, Italy
[4] Univ Coll Dublin, Sch Publ Hlth Physiotherapy & Populat Sci, Dublin 2, Ireland
关键词
maximal anaerobic power; explosive power; fitness assessment; stretch shortening cycle; PHYSIOLOGICAL-CHARACTERISTICS; MECHANICAL POWER; ELASTIC ENERGY; RELIABILITY; STRENGTH; HEIGHT; CONTACT; SOCCER; OUTPUT;
D O I
10.1519/JSC.0b013e31825dbcc5
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Castagna, C, Ganzetti, M, Ditroilo, M, Giovannelli, M, Rocchetti, A, and Manzi, V. Concurrent validity of vertical jump performance assessment systems. J Strength Cond Res 27(3): 761-768, 2013-The aim of this study was to examine the concurrent validity of 2 portable systems for vertical jump (VJ) assessment under field conditions. The VJ flight times assessed using an optical mat (Optojump) and an accelerometer-based (Myotest) system were compared with that of a force platform. The flight times recorded during a countermovement jump (CMJ) were collected from 20 rugby players (n = 86 jumps) concurrently using the 3 tracking systems. Significant bias between the Force platform and either the Optojump (bias = 0.006 +/- 0.007; 95% confidence interval [CI] 0.004-0.007 seconds) and Myotest (bias = -0.031 +/- 0.021; 95% CI 0.035 to -0.026s; p < 0.0001) occurred. A nearly perfect correlation was found between force platform and Optojump (r = 0.99; 95% CI 0.098-0.99; p < 0.0001). Force platform and Myotest (r = 0.89; 95% CI 0.084-0.93; p < 0.0001) flight times showed very large association. Difference between Optojump and Myotest systems was significant (-0.036 +/- 0.021 seconds; 95% CI -0.041 to -0.032; p < 0.0001), which results in Myotest mean flight time being approximately 7.2% longer than the Optojump flight time. The association between Optojump and Myotest was nearly perfect (r = 0.91, 95% CI 0.86-0.94; p < 0.0001). This study showed that the Optojump and Myotest systems possess convergent validity and can be successfully used under field conditions to assess VJ while performing a CMJ. However, caution should be exercised when interpreting data obtained from different portable systems for field measurement.
引用
收藏
页码:761 / 768
页数:8
相关论文
共 39 条
  • [1] STORAGE OF ELASTIC ENERGY IN SKELETAL-MUSCLES IN MAN
    ASMUSSEN, E
    BONDEPET.F
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1974, 91 (03): : 385 - 392
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] MECHANICAL POWER TEST AND FIBER COMPOSITION OF HUMAN LEG EXTENSOR MUSCLES
    BOSCO, C
    KOMI, PV
    TIHANYI, J
    FEKETE, G
    APOR, P
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 51 (01): : 129 - 135
  • [4] INFLUENCE OF AGING ON THE MECHANICAL-BEHAVIOR OF LEG EXTENSOR MUSCLES
    BOSCO, C
    KOMI, PV
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 45 (2-3): : 209 - 219
  • [5] STORE AND RECOIL OF ELASTIC ENERGY IN SLOW AND FAST TYPES OF HUMAN SKELETAL-MUSCLES
    BOSCO, C
    TIHANYI, J
    KOMI, PV
    FEKETE, G
    APOR, P
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1982, 116 (04): : 343 - 349
  • [6] A SIMPLE METHOD FOR MEASUREMENT OF MECHANICAL POWER IN JUMPING
    BOSCO, C
    LUHTANEN, P
    KOMI, PV
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 50 (02): : 273 - 282
  • [7] A COMPARISON OF 2 OPTICAL TIMING SYSTEMS DESIGNED TO MEASURE FLIGHT TIME AND CONTACT TIME DURING JUMPING AND HOPPING
    Bosquet, Laurent
    Berryman, Nicolas
    Dupuy, Olivier
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (09) : 2660 - 2665
  • [8] The effect of a resistance training programme on the grab, track and swing starts in swimming
    Breed, RVP
    Young, WB
    [J]. JOURNAL OF SPORTS SCIENCES, 2003, 21 (03) : 213 - 220
  • [9] VALIDITY AND RELIABILITY OF THE MYOTEST ACCELEROMETRIC SYSTEM FOR THE ASSESSMENT OF VERTICAL JUMP HEIGHT
    Casartelli, Nicola
    Mueller, Roland
    Maffiuletti, Nicola A.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2010, 24 (11) : 3186 - 3193
  • [10] Cohen J., 1988, Statistical power analysis for the behavioral sciences, VSecond