CONCURRENT VALIDITY OF VERTICAL JUMP PERFORMANCE ASSESSMENT SYSTEMS

被引:100
作者
Castagna, Carlo [1 ,2 ]
Ganzetti, Marco [3 ]
Ditroilo, Massimiliano [4 ]
Giovannelli, Marco [2 ]
Rocchetti, Alessandro [3 ]
Manzi, Vincenzo [1 ]
机构
[1] Italian Football Federat FIGC, Tech Dept, Football Training & Biomech Lab, Florence, Italy
[2] Italian Olymp Comm, Marche Reg Sch Sport, Ancona, Italy
[3] Myolab Performance, Jesi, Italy
[4] Univ Coll Dublin, Sch Publ Hlth Physiotherapy & Populat Sci, Dublin 2, Ireland
关键词
maximal anaerobic power; explosive power; fitness assessment; stretch shortening cycle; PHYSIOLOGICAL-CHARACTERISTICS; MECHANICAL POWER; ELASTIC ENERGY; RELIABILITY; STRENGTH; HEIGHT; CONTACT; SOCCER; OUTPUT;
D O I
10.1519/JSC.0b013e31825dbcc5
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Castagna, C, Ganzetti, M, Ditroilo, M, Giovannelli, M, Rocchetti, A, and Manzi, V. Concurrent validity of vertical jump performance assessment systems. J Strength Cond Res 27(3): 761-768, 2013-The aim of this study was to examine the concurrent validity of 2 portable systems for vertical jump (VJ) assessment under field conditions. The VJ flight times assessed using an optical mat (Optojump) and an accelerometer-based (Myotest) system were compared with that of a force platform. The flight times recorded during a countermovement jump (CMJ) were collected from 20 rugby players (n = 86 jumps) concurrently using the 3 tracking systems. Significant bias between the Force platform and either the Optojump (bias = 0.006 +/- 0.007; 95% confidence interval [CI] 0.004-0.007 seconds) and Myotest (bias = -0.031 +/- 0.021; 95% CI 0.035 to -0.026s; p < 0.0001) occurred. A nearly perfect correlation was found between force platform and Optojump (r = 0.99; 95% CI 0.098-0.99; p < 0.0001). Force platform and Myotest (r = 0.89; 95% CI 0.084-0.93; p < 0.0001) flight times showed very large association. Difference between Optojump and Myotest systems was significant (-0.036 +/- 0.021 seconds; 95% CI -0.041 to -0.032; p < 0.0001), which results in Myotest mean flight time being approximately 7.2% longer than the Optojump flight time. The association between Optojump and Myotest was nearly perfect (r = 0.91, 95% CI 0.86-0.94; p < 0.0001). This study showed that the Optojump and Myotest systems possess convergent validity and can be successfully used under field conditions to assess VJ while performing a CMJ. However, caution should be exercised when interpreting data obtained from different portable systems for field measurement.
引用
收藏
页码:761 / 768
页数:8
相关论文
共 39 条
[1]   STORAGE OF ELASTIC ENERGY IN SKELETAL-MUSCLES IN MAN [J].
ASMUSSEN, E ;
BONDEPET.F .
ACTA PHYSIOLOGICA SCANDINAVICA, 1974, 91 (03) :385-392
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   MECHANICAL POWER TEST AND FIBER COMPOSITION OF HUMAN LEG EXTENSOR MUSCLES [J].
BOSCO, C ;
KOMI, PV ;
TIHANYI, J ;
FEKETE, G ;
APOR, P .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 51 (01) :129-135
[4]   INFLUENCE OF AGING ON THE MECHANICAL-BEHAVIOR OF LEG EXTENSOR MUSCLES [J].
BOSCO, C ;
KOMI, PV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 45 (2-3) :209-219
[5]   STORE AND RECOIL OF ELASTIC ENERGY IN SLOW AND FAST TYPES OF HUMAN SKELETAL-MUSCLES [J].
BOSCO, C ;
TIHANYI, J ;
KOMI, PV ;
FEKETE, G ;
APOR, P .
ACTA PHYSIOLOGICA SCANDINAVICA, 1982, 116 (04) :343-349
[6]   A SIMPLE METHOD FOR MEASUREMENT OF MECHANICAL POWER IN JUMPING [J].
BOSCO, C ;
LUHTANEN, P ;
KOMI, PV .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 50 (02) :273-282
[7]   A COMPARISON OF 2 OPTICAL TIMING SYSTEMS DESIGNED TO MEASURE FLIGHT TIME AND CONTACT TIME DURING JUMPING AND HOPPING [J].
Bosquet, Laurent ;
Berryman, Nicolas ;
Dupuy, Olivier .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (09) :2660-2665
[8]   The effect of a resistance training programme on the grab, track and swing starts in swimming [J].
Breed, RVP ;
Young, WB .
JOURNAL OF SPORTS SCIENCES, 2003, 21 (03) :213-220
[9]   VALIDITY AND RELIABILITY OF THE MYOTEST ACCELEROMETRIC SYSTEM FOR THE ASSESSMENT OF VERTICAL JUMP HEIGHT [J].
Casartelli, Nicola ;
Mueller, Roland ;
Maffiuletti, Nicola A. .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2010, 24 (11) :3186-3193
[10]  
Cohen J., 1988, Statistical power analysis for the behavioral sciences, VSecond