Sign of eye irritation in female hospital workers and the indoor environment

被引:38
作者
Smedbold, HT [2 ]
Ahlen, C
Norbäck, D
Hilt, B
机构
[1] Norwegian Univ Sci & Technol, Inst Environm Med, N-7006 Trondheim, Norway
[2] Univ Trondheim Hosp, Dept Occupat Med, N-7006 Trondheim, Norway
[3] Sintef Unimed, Sect Extreme Work Environm, Trondheim, Norway
[4] Univ Uppsala Hosp, Dept Occupat & Environm Med, Uppsala, Sweden
[5] Uppsala Univ, Dept Med Sci, Uppsala, Sweden
关键词
tear-film break-up time; vital staining; microbial flora; traffic pollution; dust settlement;
D O I
10.1034/j.1600-0668.2001.110403.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The relationships between indoor environment factors and signs of eye irritation were studied in a sample of female personnel with (n=112) and without (n=64) mucous membrane symptoms working in 36 nursing departments at geriatric hospitals in the municipality of Trondheim, Norway. The indoor climate was characterised by high room temperature (interquartile range 23.0-23.7 degreesC), low relative air humidity (interquartile range 17-26%) and high outdoor airflow rate, as indicated by low indoor levels of carbon dioxide (interquartile range 490-650 ppm). An altered microbial flora was observed in nine of the departments, and Aspergillus fumigatus was found in three of these. Five of the hospitals were situated in urban parts of the municipality near roads with heavy traffic. In the initial analyses decreased tear-film stability (BUT) was observed in subjects working in departments with increased dust settlement rate (P=0.03), in hospitals situated in urban areas with heavy traffic (P <0.001), and in subjects working in departments with presence of A. fumigatus (P=0.04). Increased conjunctival staining (CS) was related to alteration of the microbial flora. In the final multivariate analyses statistically significant relationships were observed between BUT and dust settlement rate and urban vicinity of workplace and between CS and alteration of the microbial flora.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 45 条
  • [1] AHLEN C, 1995, P IND AIR QUAL PRACT, P255
  • [2] Andersson K, 1998, INDOOR AIR, P32
  • [3] Andersson K., 1992, NATO/OCCM Pilot Study on Indoor Air Quality, P47
  • [4] [Anonymous], 1993, Journal of Indoor Air, DOI DOI 10.1111/J.1600-0668.1993.T01-1-00002.X
  • [5] APTER A, 1994, J ALLERGY CLIN IMMUN, V94, P277, DOI 10.1016/0091-6749(94)90087-6
  • [6] LOW FLOW OF TEARS - THE DRY EYE
    DEROETTH, AFM
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1952, 35 (06) : 782 - 787
  • [7] FERRECCHI P, 1999, RELAZIONE ANN SULLA
  • [8] FLANNIGAN B, 1994, AIR QUAL MG, V2, P3
  • [9] FLANNIGAN B, 1992, EURO CH ENV, V4, P73
  • [10] FRANCK C, 1986, ACTA OPHTHALMOL, V64, P306