Effect of anastomosis angle on the localization of disturbed flow in side-to-end fistulae for haemodialysis access

被引:105
作者
Ene-Iordache, Bogdan [1 ]
Cattaneo, Luca [2 ]
Dubini, Gabriele [2 ]
Remuzzi, Andrea [1 ,3 ]
机构
[1] Mario Negri Inst Pharmacol Res, Clin Res Ctr Rare Dis Aldo & Cele Dacco, Ranica, BG, Italy
[2] Politecn Milan, Dept Struct Engn, Lab Biol Struct Mech LaBS, I-20133 Milan, MI, Italy
[3] Univ Bergamo, Dept Ind Engn, Dalmine, BG, Italy
基金
欧盟第七框架计划;
关键词
anastomosis angle; arteriovenous fistula; computational fluid dynamics; intimal hyperplasia; stenosis; ARTERIOVENOUS-FISTULA; VASCULAR ACCESS; PULSATILE FLOW; AV FISTULAS; STENOSIS; FAILURE; HEMODYNAMICS; LESIONS; GRAFTS; SITES;
D O I
10.1093/ndt/gfs298
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Early failure of the vascular access for haemodialysis (HD) after the surgical creation of a radial-cephalic arteriovenous fistula (AVF) occurs mainly due to a juxta-anastomotic stenosis. Even if elevated blood flow induces high wall shear stress, we have recently shown that disturbed flow, characterized by low and reciprocating flow, may develop in zones of the AVF where it can provide a good indication of the sites of future stenoses. The present study was aimed at investigating whether the anastomosis angle influences disturbed flow in radial-cephalic side-to-end AVF. By means of a parametric AVF model we created four equivalent meshes with anastomosis angles of 30, 45, 60 and 90, respectively. We then performed transient, non-Newtonian computational fluid dynamics simulations using, as boundary conditions, previously measured blood volume flow and division ratio in subjects requiring primary access. The relative residence time (RRT), a robust indicator of disturbed flow, was calculated for the overall wall surface and disturbed flow was localized as areas having RRT 1. Quantitative characterization and statistical tests were employed to assess the difference in RRT medians between the four anastomosis angle cases. Disturbed flow was located in all AVF models in the same areas where flow recirculation and stagnation occurred, on the inner wall of the swing segment (SS) and on the arterial wall at the anastomosis floor (AF). A smaller angle AVF had smaller disturbed flow areas with lower RRT peak values, either on the venous or the arterial limb. There were significant differences in the RRT medians on the SS and on the AF between sharper (30 and 45) and wider (60 or 90) angles. We have found that in side-to-end radial-cephalic AVFs for HD, the anastomosis angle does impact on the local disturbed flow patterns. Among the four geometries we considered in this study, the smaller angle (30) would be the preferred choice that minimizes the development of neointima. Clinicians should consider this at the time of AVF creation because the anastomosis angle is in part amenable to surgical manipulation.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 27 条
[1]  
[Anonymous], NUMP SCI COMP TOOLS
[2]  
[Anonymous], PAR OP SOURC SCI VIS
[3]  
[Anonymous], 2013, R LANG ENV STAT COMP
[4]   Early arteriovenous fistula failure: A logical proposal for when and how to intervene [J].
Asif, Arif ;
Roy-Chaudhury, Prabir ;
Beathard, Gerald A. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 1 (02) :332-339
[5]   Frequency of swing-segment stenosis in referred dialysis patients with angiographically documented lesions [J].
Badero, Olurotimi J. ;
Salifu, Moro O. ;
Wasse, Haimanot ;
Work, Jack .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2008, 51 (01) :93-98
[6]   Aggressive treatment of early fistula failure [J].
Beathard, GA ;
Arnold, P ;
Jackson, J ;
Litchfield, T .
KIDNEY INTERNATIONAL, 2003, 64 (04) :1487-1494
[7]   On reducing abnormal hemodynamics in the femoral end-to-side anastomosis: The influence of mechanical factors [J].
Brien, TO ;
Walsh, M ;
McGloughlin, T .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (03) :310-322
[8]   Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access [J].
Corpataux, JM ;
Haesler, E ;
Silacci, P ;
Ris, HB ;
Hayoz, D .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 (06) :1057-1062
[9]   Numerical simulation of the haemodynamics in end-to-side anastomoses [J].
Do, Hung ;
Owida, Amal A. ;
Yang, William ;
Morsi, Yos S. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2011, 67 (05) :638-650
[10]   Radial artery remodeling in response to shear stress increase within arteriovenous fistula for hemodialysis access [J].
Ene-Iordache, B ;
Mosconi, L ;
Antiga, L ;
Bruno, S ;
Anghileri, A ;
Remuzzi, G ;
Remuzzi, A .
ENDOTHELIUM-JOURNAL OF ENDOTHELIAL CELL RESEARCH, 2003, 10 (02) :95-102