Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols

被引:26
作者
Neefjes, Lisan A. [1 ,2 ,4 ]
Rossi, Alexia [1 ,2 ]
Genders, Tessa S. S. [2 ,3 ]
Nieman, Koen [1 ,2 ]
Papadopoulou, Stella L. [1 ,2 ]
Dharampal, Anoeshka S. [1 ,2 ]
Schultz, Carl J. [1 ]
Weustink, Annick C. [2 ]
Dijkshoorn, Marcel L. [2 ]
ten Kate, Gert-Jan R. [1 ,2 ,4 ]
Dedic, Admir [1 ,2 ]
van Straten, Marcel [2 ]
Cademartiri, Filippo [2 ]
Hunink, M. G. Myriam [2 ,3 ]
Krestin, Gabriel P. [2 ]
de Feyter, Pim J. [1 ,2 ]
Mollet, Nico R. [1 ,2 ]
机构
[1] Erasmus MC, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
[3] Erasmus MC, Dept Epidemiol, NL-3000 CA Rotterdam, Netherlands
[4] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
Computed tomography; Coronary angiography; Coronary artery disease; Radiation dosage; Sensitivity and specificity; AMERICAN-HEART-ASSOCIATION; RADIATION-DOSE REDUCTION; COMPUTED-TOMOGRAPHY; HIGH-PITCH; IMAGE QUALITY; PERFORMANCE; EXPOSURE; STRATEGIES; CARDIOLOGY; RADIOLOGY;
D O I
10.1007/s00330-012-2663-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction. We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients. In group A (231 patients, 146 men, mean heart rate 58 +/- 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 +/- 0.60 vs. 3.82 +/- 1.65 mSv, P < 0.001). In group B (228 patients, 132 men, mean heart rate 75 +/- 11 bpm), per-segment sensitivity, specificity, PPV and NPV were comparable (94 %, 95 %, 67 %, 99 % vs. 92 %, 95 %, 66 %, 99 %, P > 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 +/- 2.58 vs. 8.13 +/- 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups. Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose.
引用
收藏
页码:614 / 622
页数:9
相关论文
共 50 条
  • [31] Detection of coronary artery anomalies by dual-source CT coronary angiography
    Cheng, Z.
    Wang, X.
    Duan, Y.
    Wu, L.
    Wu, D.
    Liang, C.
    Liu, C.
    Xu, Z.
    CLINICAL RADIOLOGY, 2010, 65 (10) : 815 - 822
  • [32] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Goetti, Robert
    Feuchtner, Gudrun
    Stolzmann, Paul
    Desbiolles, Lotus
    Fischer, Michael Alexander
    Karlo, Christoph
    Baumueller, Stephan
    Scheffel, Hans
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2010, 20 (11) : 2565 - 2571
  • [33] Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT: optimization of the CT protocol to reduce the radiation dose
    Kim, Sung Mok
    Kim, Yoo Na
    Choe, Yeon Hyeon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04) : 875 - 884
  • [34] Dual-source CT coronary angiography. Diagnostic accuracy without the use of B blockers
    Saad, Mohammad Ahmad M.
    Azer, Hany Younan
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2011, 42 (3-4) : 281 - 287
  • [35] Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience
    Leschka, Sebastian
    Stolzmann, Paul
    Desbiolles, Lotus
    Baumueller, Stephan
    Goetti, Robert
    Schertler, Thomas
    Scheffel, Hans
    Plass, Andre
    Falk, Volkmar
    Feuchtner, Gudrun
    Marincek, Borut
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2009, 19 (12) : 2896 - 2903
  • [36] Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note
    Feuchtner, Gudrun
    Goetti, Robert
    Plass, Andre
    Baumueller, Stephan
    Stolzmann, Paul
    Scheffel, Hans
    Wieser, Monika
    Marincek, Borut
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2092 - 2099
  • [37] 128-Slice Acceletated-Pitch Dual Energy CT Angiography of the Head and Neck: Comparison of Different Low Contrast Medium Volumes
    Chen, Yu
    Xue, Huadan
    Jin, Zheng-yu
    Zhang, Jie
    Sun, Hao
    Wang, Xuan
    Zhang, Zhu-hua
    Zhang, Da-ming
    Lu, Guang-ming
    Zhang, Zhao-qi
    Schoepf, U. Joseph
    Bucher, Andreas M.
    Wolla, Christopher D.
    Wang, Yun
    PLOS ONE, 2013, 8 (11):
  • [38] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Ming-li Sun
    Bin Lu
    Run-ze Wu
    Laura Johnson
    Lei Han
    Gang Liu
    Fang-Fang Yu
    Zhi-hui Hou
    Yang Gao
    Hong-yu Wang
    Shiliang Jiang
    Yue-jin Yang
    Shu-bin Qiao
    European Radiology, 2011, 21 : 1635 - 1642
  • [39] Diagnostic performance and radiation dose of lower extremity CT angiography using a 128-slice dual source CT at 80 kVp and high pitch
    Kim, Jin Woo
    Choo, Ki Seok
    Jeon, Ung Bae
    Kim, Tae Un
    Hwang, Jae Yeon
    Yeom, Jeong A.
    Jeong, Hee Seok
    Choi, Yoon Young
    Nam, Kyung Jin
    Kim, Chang Won
    Jeong, Dong Wook
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2016, 57 (07) : 822 - 828
  • [40] Low-Dose Scan Protocols in Dual-Source CT Coronary Angiography
    Li, Min
    Sun, Gang
    RADIOLOGY, 2012, 263 (03) : 937 - 938