A Preliminary Comparative Study of Young's Modulus Versus Shear Modulus in the Diagnosis of Breast Cancer

被引:10
|
作者
Wu, Huaiyu [1 ]
Liang, Weiyu [1 ]
Jiao, Yang [1 ]
Song, Hong [1 ]
Peng, Quanzhou [2 ]
Luo, Hui [1 ]
Zhang, Yuanji [1 ]
Xu, Jinfeng [1 ,2 ]
Dong, Fajin [1 ,2 ]
机构
[1] Jinan Univ, Shenzhen Peoples Hosp, Shenzhen Med Ultrasound Engn Ctr, Dept Ultrasound,Clin Med Coll 2, 1017 Dongmen North Rd, Shenzhen 518020, Peoples R China
[2] Jinan Univ, Clin Med Coll 2, Shenzhen Peoples Hosp, Dept Pathol, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
elastic imaging technique; shear modulus; Young's modulus; breast cancer; differential diagnosis; WAVE ELASTOGRAPHY; SCREENING US; ULTRASOUND; WOMEN; MAMMOGRAPHY; MASSES;
D O I
10.1097/RUQ.0000000000000434
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to compare the diagnostic value of Young's modulus (E) and shear modulus (G) in the differential diagnosis of benign and malignant breast masses using sound touch elastography (STE) and to explore the relationship between G and E in breast lesions. Methods A total of 96 consecutive women with 110 pathologically confirmed breast masses were included. All masses were detected by conventional and STE ultrasound. E-mean, E-max, E-min, E-SD, G(mean), G(max), G(min), and G(SD) were determined and evaluated for evidence of significant differences between benign and malignant breast masses. Receiver operator characteristics were used to compare the diagnostic efficacy of E and G and to determine the G cutoff value that would aid in the differential diagnosis of breast cancer. ResultsE(mean), E-max, E-SD, G(mean), G(max), and G(SD) in cases of malignant breast masses were significantly higher than those in cases of benign masses (P < 0.05). There was no significant difference between E-min and G(min) (P = 0.565). In applying the E-mean, E-max, E-SD, G(mean), G(max), and G(SD) to the receiver operator characteristics: (1) the area under the curve (AUC) of G(mean) and G(max) is greater than the AUC of E-mean and E-max, and the AUC of E-SD is equal to the AUC of G(SD). (2) The sensitivity and specificity were highest when the G(mean) was 10.14 kPa. They were 84.1% and 80.3% respectively. (3) The sensitivity and specificity were highest when the G(max) was 52.20 kPa. They were 88.6% and 87.9% respectively. Conclusions These preliminary results of STE evaluation of breast masses suggest that the diagnostic value of G is greater than E. Furthermore, STE is a valuable tool in the differential diagnosis of breast lesions.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 50 条
  • [21] Unusually high ratio of shear modulus to Young's modulus in a nano-structured gyroid metamaterial
    Park, Jun-Hyoung
    Lee, Jae-Chul
    SCIENTIFIC REPORTS, 2017, 7
  • [22] Measurement of the Young's modulus and shear modulus of extruded polystyrene foam by the longitudinal and flexural vibration methods
    Yoshihara, Hiroshi
    Ataka, Naoki
    Maruta, Makoto
    JOURNAL OF CELLULAR PLASTICS, 2018, 54 (02) : 199 - 216
  • [23] Bulk modulus and young's modulus of nanocrystalline γ-alumina
    Gallas, Marcia R.
    Piermarini, Gasper J.
    Journal of the American Ceramic Society, 1994, 77 (11): : 2917 - 2920
  • [24] Experimental study on Young’s modulus of concrete
    Shi-you Wen
    Xi-bing Li
    Journal of Central South University of Technology, 2000, 7 : 43 - 45
  • [25] Study of measuring Young's modulus with CCD
    Wang, Guangxue
    Zhu, Zixiang
    Li, Yurong
    Guangxue Jishu/Optical Technique, 1994, (04): : 31 - 34
  • [26] Experimental study on Young's modulus of concrete
    Wen, SY
    Li, XB
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2000, 7 (01): : 43 - 45
  • [27] Shear-wave elastography for breast masses: local shear wave speed (m/sec) versus Young modulus (kPa)
    Youk, Ji Hyun
    Son, Eun Ju
    Park, Ah Young
    Kim, Jeong-Ah
    ULTRASONOGRAPHY, 2014, 33 (01) : 34 - 39
  • [28] Simultaneously obtaining the Young's relaxation modulus and shear relaxation modulus of an epoxy molding compound by using DMA
    Chen, Dao-Long
    Chiu, Tz-Cheng
    Chen, Tei-Chen
    Yang, Ping-Feng
    Hung, Chih-Pin
    Fang, Jen-Kuang
    2014 IEEE 16TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE (EPTC), 2014, : 171 - 174
  • [29] EVALUATION OF PRECISE MEASUREMENTS OF YOUNG'S MODULUS AND SHEAR MODULUS BY THE ELECTRO-STATE DRIVING METHOD.
    Tanji, Yasunori
    Moriya, Hiroshi
    Oguma, Ichiro
    Shirakawa, Yuki
    1600, (25):
  • [30] Analysis of in-plane elastic modulus for a hexagonal honeycomb core (2nd report, analysis of young's modulus and shear modulus)
    Department of Mechanical Engineering, Tokyo University of Science, 1-3 Kagurazaka, Shinjuku-ku, Tokyo, 162-8601, Japan
    Nihon Kikai Gakkai Ronbunshu A, 2007, 5 (595-602):