Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant

被引:5
作者
Melo de Matos, Jefferson David [1 ,2 ]
Scalzer Lopes, Guilherme da Rocha [2 ]
Queiroz, Daher Antonio [3 ]
Jesus Pereira, Andre Luiz [4 ]
Coelho Sinhoreti, Mario Alexandre [5 ]
Ramos, Nathalia de Carvalho [2 ,6 ,7 ]
Lino, Vinicius [2 ]
de Oliveira, Flavio Rosa [2 ]
Souto Borges, Alexandre Luiz [2 ]
Bottino, Marco Antonio [2 ]
机构
[1] Univ Florida, Ctr Dent Biomat, Dept Restorat Dent Sci, UF Hlth, Gainesville, FL 32601 USA
[2] Sao Paulo State Univ, Inst Sci & Technol, Dept Biomat Dent Mat & Prosthodont, UNESP, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[3] Univ Texas Hlth Sci Ctr Houston UTHlth, Sch Dent, Dept Restorat Dent & Prosthodont, Houston, TX 77054 USA
[4] Aeronaut Technol Inst ITA, Phys Dept, Plasmas & Proc Lab, 50 Marechal Eduardo Gomes Sq, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[5] FOP UNICAMP, Dept Restorat Dent, Dent Mat Div, Piracicaba Dent Sch, BR-13416000 Piracicaba, SP, Brazil
[6] Univ Sao Francisco USF, Dept Dent, BR-12916900 Braganca Paulista, SP, Brazil
[7] Univ Taubate UNITAU, Dept Dent, Postgrad Program Dent, BR-12080000 Taubate, SP, Brazil
关键词
bioengineering; dental abutments; dental implants; dental materials; polyetheretherketone; IN-VITRO EVALUATION; STRESS-DISTRIBUTION; FRAMEWORK; FORCE; DEFORMATION; PROSTHESIS; INTERFACE; DESIGN; ALLOY;
D O I
10.3390/ma15228133
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 x 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 x 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30 degrees) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30 degrees). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Original vs. non-original abutments for screw-retained single implant crowns: An in vitro evaluation of internal fit, mechanical behaviour and screw loosening
    Alonso-Perez, Raquel
    Bartolome, Jose F.
    Ferreiroa, Alberto
    Salido, Maria P.
    Pradies, Guillermo
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1230 - 1238
  • [32] PHOTOELASTIC STRESS ANALYSIS OF EXTERNAL VERSUS INTERNAL IMPLANT-ABUTMENT CONNECTIONS
    Asvanund, Pattapon
    Morgano, Steven M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (04) : 266 - 271
  • [33] In vitro assessment of connection strength and stability of internal implant-abutment connections
    Kofron, Michelle D.
    Carstens, Matthew
    Fu, Cong
    Wen, Hai Bo
    CLINICAL BIOMECHANICS, 2019, 65 : 92 - 99
  • [34] Influence of loading conditions on the overall mechanical behavior of polyether-ether-ketone (PEEK)
    Abbasnezhad, N.
    Khavandi, A.
    Fitoussi, J.
    Arabi, H.
    Shirinbayan, M.
    Tcharkhtchi, A.
    INTERNATIONAL JOURNAL OF FATIGUE, 2018, 109 : 83 - 92
  • [35] Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study
    Cascos, Rocio
    Celemin-Vinuela, Alicia
    Mory-Rubinos, Nataly
    Gomez-Polo, Cristina
    Ortega, Rocio
    Agustin-Panadero, Ruben
    Gomez-Polo, Miguel
    MATERIALS, 2023, 16 (19)
  • [36] An In Vitro Analysis of the Physical and Mechanical Behavior of a PEEK Component for an Implant-Supported and Retained Removable Dental Prosthesis
    da Costa Valente, Mariana Lima
    da Silva, Geyson Galo
    Bachmann, Luciano
    Marcondes Agnelli, Jose Augusto
    dos Reis, Andrea Candido
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (05) : 612 - 619
  • [37] Influence of implant connection on the stress distribution in restorations performed with hybrid abutments
    Tribst, J. P. M.
    Dal Piva, A. M. O.
    Anami, L. C.
    Borges, A. L. S.
    Bottino, M. A.
    JOURNAL OF OSSEOINTEGRATION, 2019, 11 (03) : 507 - 512
  • [38] Evaluation of the Mechanical Reliability of Different Implant-Abutment Connections for Single Crowns According to the ISO 14801 Fatigue Test Protocol
    Thome, Geninho
    Torres Gomes, Andre Felipe
    de Moura, Marcos Boaventura
    Beng, Christian Felippi
    Trojan, Larissa Carvalho
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (01) : 47 - 54
  • [39] Influence of Different Screw Torque Levels on the Biomechanical Behavior of Tapered Prosthetic Abutments
    Herbst, Paulo Eduardo
    de Carvalho, Eduardo Bortolas
    Salatti, Rafael C.
    Valgas, Laiz
    Tiossi, Rodrigo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (03) : 536 - 540
  • [40] Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants
    Gil, F. J.
    Herrero-Climent, M.
    Lazaro, P.
    Rios, J. V.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (07) : 1825 - 1830