Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant

被引:5
|
作者
Melo de Matos, Jefferson David [1 ,2 ]
Scalzer Lopes, Guilherme da Rocha [2 ]
Queiroz, Daher Antonio [3 ]
Jesus Pereira, Andre Luiz [4 ]
Coelho Sinhoreti, Mario Alexandre [5 ]
Ramos, Nathalia de Carvalho [2 ,6 ,7 ]
Lino, Vinicius [2 ]
de Oliveira, Flavio Rosa [2 ]
Souto Borges, Alexandre Luiz [2 ]
Bottino, Marco Antonio [2 ]
机构
[1] Univ Florida, Ctr Dent Biomat, Dept Restorat Dent Sci, UF Hlth, Gainesville, FL 32601 USA
[2] Sao Paulo State Univ, Inst Sci & Technol, Dept Biomat Dent Mat & Prosthodont, UNESP, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[3] Univ Texas Hlth Sci Ctr Houston UTHlth, Sch Dent, Dept Restorat Dent & Prosthodont, Houston, TX 77054 USA
[4] Aeronaut Technol Inst ITA, Phys Dept, Plasmas & Proc Lab, 50 Marechal Eduardo Gomes Sq, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[5] FOP UNICAMP, Dept Restorat Dent, Dent Mat Div, Piracicaba Dent Sch, BR-13416000 Piracicaba, SP, Brazil
[6] Univ Sao Francisco USF, Dept Dent, BR-12916900 Braganca Paulista, SP, Brazil
[7] Univ Taubate UNITAU, Dept Dent, Postgrad Program Dent, BR-12080000 Taubate, SP, Brazil
关键词
bioengineering; dental abutments; dental implants; dental materials; polyetheretherketone; IN-VITRO EVALUATION; STRESS-DISTRIBUTION; FRAMEWORK; FORCE; DEFORMATION; PROSTHESIS; INTERFACE; DESIGN; ALLOY;
D O I
10.3390/ma15228133
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 x 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 x 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30 degrees) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30 degrees). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing
    Ortega-Martinez, Jordi
    Delgado, Luis M.
    Ortiz-Hernandez, Monica
    Punset, Miquel
    Cano-Batalla, Jordi
    Roig Cayon, Miguel
    Cabratosa-Termes, Josep
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03) : 470 - 476
  • [2] Review of the Mechanical Behavior of Different Implant-Abutment Connections
    Vinhas, Ana Sofia
    Aroso, Carlos
    Salazar, Filomena
    Lopez-Jarana, Paula
    Rios-Santos, Jose Vicente
    Herrero-Climent, Mariano
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (22) : 1 - 20
  • [3] Mechanical Behavior of Five Different Morse Taper Implants and Abutments with Different Conical Internal Connections and Angles: An In Vitro Experimental Study
    Caballero, Claudia
    Rodriguez, Fernando
    Cortellari, Guillermo Castro
    Scarano, Antonio
    Prados-Frutos, Juan Carlos
    De Aza, Piedad N.
    Fernandes, Gustavo Vicentis Oliveira
    Gehrke, Sergio Alexandre
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (07)
  • [4] Impact of Diamond-like Carbon Films on Reverse Torque: Superior Performance in Implant Abutments with Internal Conical Connections
    Coelho, Arianne Vallim Pinto
    de Figueiredo, Viviane Maria Goncalves
    Ferreira, Leandro Lameirao
    Silva, Alecsandro de Moura
    Oliani, Marcelo Gallo
    de Queiroz, Jose Renato Cavalcanti
    Sobrinho, Argemiro Soares da Silva
    Nogueira Junior, Lafayette
    do Prado, Renata Falchete
    COATINGS, 2024, 14 (09)
  • [5] Load to failure of different zirconia abutments for an internal hexagon implant
    Yilmaz, Burak
    Salaita, Louai G.
    Seidt, Jeremy D.
    McGlumphy, Edwin A.
    Clelland, Nancy L.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (03) : 373 - 377
  • [6] Discrepancies in marginal and internal fits for different metal and alumina infrastructures cemented on implant abutments
    Faot, Fernanda
    Suzuki, Dalton
    Senna, Plinio M.
    da Silva, Wander J.
    de Mattias Sartori, Ivete A.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2015, 123 (03) : 215 - 219
  • [7] Mechanical analysis of conventional and small diameter conical implant abutments
    Mauricio Moris, Izabela Cristina
    Lapria Faria, Adriana Claudia
    Chiarello de Mattos, Maria da Gloria
    Ribeiro, Ricardo Faria
    Silveira Rodrigues, Renata Cristina
    JOURNAL OF ADVANCED PROSTHODONTICS, 2012, 4 (03) : 158 - 161
  • [8] INFLUENCE OF REVERSE TORQUE VALUES IN ABUTMENTS WITH OR WITHOUT INTERNAL HEXAGON INDEXES
    Cerutti-Kopplin, Daiane
    Rodrigues Neto, Dimas Joao
    do Valle, Accacio Lins
    Pereira, Jefferson Ricardo
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (04) : 824 - 827
  • [9] Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections
    Siadat, Hakimeh
    Beyabanaki, Elaheh
    Mousavi, Niloufar
    Alikhasi, Marzieh
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04) : 271 - 277
  • [10] Mechanical Testing of Implant-Supported Anterior Crowns with Different Implant/Abutment Connections
    Almeida, Erika O.
    Freitas, Amilcar C., Jr.
    Bonfante, Estevam A.
    Marotta, Leonard
    Silva, Nelson R. F. A.
    Coelho, Paulo G.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 103 - 108