Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant
被引:5
|作者:
Melo de Matos, Jefferson David
[1
,2
]
Scalzer Lopes, Guilherme da Rocha
[2
]
Queiroz, Daher Antonio
[3
]
Jesus Pereira, Andre Luiz
[4
]
Coelho Sinhoreti, Mario Alexandre
[5
]
Ramos, Nathalia de Carvalho
[2
,6
,7
]
Lino, Vinicius
[2
]
de Oliveira, Flavio Rosa
[2
]
Souto Borges, Alexandre Luiz
[2
]
Bottino, Marco Antonio
[2
]
机构:
[1] Univ Florida, Ctr Dent Biomat, Dept Restorat Dent Sci, UF Hlth, Gainesville, FL 32601 USA
[2] Sao Paulo State Univ, Inst Sci & Technol, Dept Biomat Dent Mat & Prosthodont, UNESP, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[3] Univ Texas Hlth Sci Ctr Houston UTHlth, Sch Dent, Dept Restorat Dent & Prosthodont, Houston, TX 77054 USA
[4] Aeronaut Technol Inst ITA, Phys Dept, Plasmas & Proc Lab, 50 Marechal Eduardo Gomes Sq, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[5] FOP UNICAMP, Dept Restorat Dent, Dent Mat Div, Piracicaba Dent Sch, BR-13416000 Piracicaba, SP, Brazil
[6] Univ Sao Francisco USF, Dept Dent, BR-12916900 Braganca Paulista, SP, Brazil
[7] Univ Taubate UNITAU, Dept Dent, Postgrad Program Dent, BR-12080000 Taubate, SP, Brazil
来源:
关键词:
bioengineering;
dental abutments;
dental implants;
dental materials;
polyetheretherketone;
IN-VITRO EVALUATION;
STRESS-DISTRIBUTION;
FRAMEWORK;
FORCE;
DEFORMATION;
PROSTHESIS;
INTERFACE;
DESIGN;
ALLOY;
D O I:
10.3390/ma15228133
中图分类号:
O64 [物理化学(理论化学)、化学物理学];
学科分类号:
070304 ;
081704 ;
摘要:
The present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 x 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 x 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30 degrees) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30 degrees). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation.