Rapid analytical methods to measure pentachlorophenol in wood

被引:29
作者
Gremaud, E [1 ]
Turesky, RJ [1 ]
机构
[1] NESTEC LTD,NESTLE RES CTR,CH-1000 LAUSANNE 26,SWITZERLAND
关键词
chlorophenols; pentachlorophenol; contamination; off-flavor; rapid detection; wood;
D O I
10.1021/jf9605963
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Pentachlorophenol (PCP) was measured in wood following extraction with methanol:0.1% acetic acid. The extract was derivatized with acetic anhydride in a biphasic solvent containing toluene and 0.1 M Na2CO3 (pH 11.4), and pentachlorophenyl acetate was quantitated by gas chromatography-mass spectrometry (GC-MS) using [C-13(6)]PCP as an internal standard. A second detection method employed thin layer chromatography (TLC) after nitric acid-mediated oxidation of PCP to tetrachloro-1,4-benzoquinone. The third method was by colorimetry and required a liquid-liquid partitioning of PCP under acidic and alkaline pH against toluene. Then, PCP was coupled to 4-aminoantipyrine in the presence of sodium persulfate to form a dye which was measured at 580 nm. The limit of detection approached 50 ppb by GC-MS and 1 ppm by TLC when 100 mg of wood was used for analysis and 1 ppm for the colorimetric method when 1 g of wood was used for detection. The estimates of PCP were comparable for all three methods.