Sensitive detection of Ferulic acid using multi-walled carbon nanotube decorated with silver nano-particles modified carbon paste electrode

被引:43
作者
Erady, Veera [1 ]
Mascarenhas, Ronald J. [1 ,2 ]
Satpati, Ashis K. [3 ]
Detriche, Simon [4 ]
Mekhalif, Zineb [4 ]
Dalhalle, Joseph [4 ]
Dhason, A. [5 ]
机构
[1] Bharathiar Univ, Res & Dev Ctr, Coimbatore 641014, Tamil Nadu, India
[2] St Josephs Coll, Dept Chem, Electrochem Res Grp, Lalbagh Rd, Bangalore 560027, Karnataka, India
[3] Bhabha Atom Res Ctr, Analyt Chem Div, Bombay 400094, Maharashtra, India
[4] Univ Namur, Lab Chim & Electrochim Surface, 61 Rue Bruxelles, B-5000 Namur, Belgium
[5] Raman Res Inst, Soft Condensed Matter, Bangalore 560080, Karnataka, India
关键词
Ferulic acid; Amperometry; Silver decorated multiwalled carbon nano tubes; Modified carbon paste electrode; Electra-catalytic oxidation; ANTICANCER DRUG 5-FLUOROURACIL; DOPED TIO2 NANOPARTICLES; ELECTROCHEMICAL SENSOR; VOLTAMMETRIC DETERMINATION; ASCORBIC-ACID; ANTIOXIDANT CAPACITY; PHENOLIC-COMPOUNDS; IONIC LIQUID; URIC-ACID; OXIDATION;
D O I
10.1016/j.jelechem.2017.10.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical oxidation of Ferulic acid (FA) was assiduously scrutinized by cyclic voltammetry and more sensitive amperometry technique using silver decorated multi-walled carbon nano-tubes modified carbon paste electrode. The modified electrode showed superior catalytic activity at physiological pH. The synergistic outcome of multiwalled carbon nano-tubes and silver nano-particles resulted in superior electro-catalytic activity and a significant three time increase of anodic peak current sensitivity and a remarkable lower energetics by 120 mV shift in potential thereby decreasing over-potential for electro-oxidation of FA in comparison to bare carbon paste electrode. Under optimized conditions, a linear dynamic range of 4.0 x 10(-8) to 1.0 x 10(-3) M, with a lower detection limit of 3.0 x 10(-8) M (S/N = 3) was obtained. The surface morphology of the sensor was studied using field emission scanning electron microscopy and atomic force microscopy. EDX was used determine the elemental composition of the electrode. The electrochemical impedance study revealed the least charge transfer resistance for the modified electrode. The effect of variation of scan rate, pH and concentration towards the electro-catalytic oxidation of FA was also investigated. Absence of peak for interfering molecules like Ascorbic acid, Uric acid and Glucose makes this sensor unique with significant analytical advantage. The fabricated sensor revealed adequate reproducibility, long term stability and enhanced selectivity in presence of commonly existing interfering molecules. The sensor was employed for the validation of spiked human urine and the wine which gave recoveries ranging from 97.5 to 99.4%, making it a potential alternative tool for the quantitative detection of FA in the biomedical field.
引用
收藏
页码:22 / 31
页数:10
相关论文
共 50 条
  • [41] Simultaneous Determination of Hydroquinone, and Catechol Using a Multi-Walled Carbon Nanotube/GC Electrode Modified by Electrodeposition of Carbon Nanodots
    Gu, Chunchuan
    Li, Xiaoping
    Liu, Hongying
    [J]. JOURNAL OF NANO RESEARCH, 2018, 54 : 42 - 53
  • [42] Electrochemical Sensor for Highly Sensitive Detection of Gallic Acid Based on Graphitized and Carboxylated Multi-Walled Carbon Nanotubes modified Glassy Carbon Electrode
    Zhu, Gan
    Wang, Qian
    Liu, Yunhang
    Guo, Meimei
    Liu, Runqiang
    Zhao, Hongyuan
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (10):
  • [43] Application of thionine-nation supported on multi-walled carbon nanotube for preparation of a modified electrode in simultaneous voltammetric detection of dopamine and ascorbic acid
    Shahrokhian, Saeed
    Zare-Mehrjardi, Hamid Reza
    [J]. ELECTROCHIMICA ACTA, 2007, 52 (22) : 6310 - 6317
  • [44] Simultaneous determination of ascorbic acid, acetaminophen and codeine based on multi-walled carbon nanotubes modified with magnetic nanoparticles paste electrode
    Taei, M.
    Salavati, H.
    Hasanpour, F.
    Habibollahi, S.
    Baghlani, H.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 1 - 11
  • [45] Multi-walled carbon nanotubes modified glassy carbon electrode for sensitive determination of ketoconazole
    Borowiec, Joanna
    Wei, Lili
    Zhu, Lihua
    Zhang, Jingdong
    [J]. ANALYTICAL METHODS, 2012, 4 (02) : 444 - 448
  • [46] Electrochemical determination of a hemorheologic drug, pentoxifylline at a multi-walled carbon nanotube paste electrode
    Abbar, Jyothi C.
    Malode, Shweta J.
    Nandibewoor, Sharanappa T.
    [J]. BIOELECTROCHEMISTRY, 2012, 83 : 1 - 7
  • [47] Voltammetric Determination of Dopamine Using Au Nanoparticles Decorated on Multi-Walled Carbon Nanotubes and β-Cyclodextrin Modified Glassy Carbon Electrode
    Varmazyar, Nasrin
    Pourghobadi, Zeinab
    Derikvand, Zohreh
    [J]. IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2024, 43 (05): : 1928 - 1936
  • [48] Electrocatalytic Determination of Carbidopa and Acetaminophen Using a Modified Carbon Nanotube Paste Electrode
    Moghaddam, Hadi Mahmoudi
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6557 - 6566
  • [49] Sensitive and selective determination of uric acid in real samples by modified glassy carbon electrode with holmium fluoride nanoparticles/multi-walled carbon nanotube as a new biosensor
    Noroozifar, M.
    Khorasani-Motlagh, M.
    Jahromi, F. Zareian
    Rostami, S.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 65 - 72
  • [50] Construction of a glassy carbon ibuprofen electrode modified with multi-walled carbon nanotubes and cyclodextrins
    Lenik, Joanna
    Nieszporek, Jolanta
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 2282 - 2289