Sensitive detection of Ferulic acid using multi-walled carbon nanotube decorated with silver nano-particles modified carbon paste electrode

被引:43
|
作者
Erady, Veera [1 ]
Mascarenhas, Ronald J. [1 ,2 ]
Satpati, Ashis K. [3 ]
Detriche, Simon [4 ]
Mekhalif, Zineb [4 ]
Dalhalle, Joseph [4 ]
Dhason, A. [5 ]
机构
[1] Bharathiar Univ, Res & Dev Ctr, Coimbatore 641014, Tamil Nadu, India
[2] St Josephs Coll, Dept Chem, Electrochem Res Grp, Lalbagh Rd, Bangalore 560027, Karnataka, India
[3] Bhabha Atom Res Ctr, Analyt Chem Div, Bombay 400094, Maharashtra, India
[4] Univ Namur, Lab Chim & Electrochim Surface, 61 Rue Bruxelles, B-5000 Namur, Belgium
[5] Raman Res Inst, Soft Condensed Matter, Bangalore 560080, Karnataka, India
关键词
Ferulic acid; Amperometry; Silver decorated multiwalled carbon nano tubes; Modified carbon paste electrode; Electra-catalytic oxidation; ANTICANCER DRUG 5-FLUOROURACIL; DOPED TIO2 NANOPARTICLES; ELECTROCHEMICAL SENSOR; VOLTAMMETRIC DETERMINATION; ASCORBIC-ACID; ANTIOXIDANT CAPACITY; PHENOLIC-COMPOUNDS; IONIC LIQUID; URIC-ACID; OXIDATION;
D O I
10.1016/j.jelechem.2017.10.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical oxidation of Ferulic acid (FA) was assiduously scrutinized by cyclic voltammetry and more sensitive amperometry technique using silver decorated multi-walled carbon nano-tubes modified carbon paste electrode. The modified electrode showed superior catalytic activity at physiological pH. The synergistic outcome of multiwalled carbon nano-tubes and silver nano-particles resulted in superior electro-catalytic activity and a significant three time increase of anodic peak current sensitivity and a remarkable lower energetics by 120 mV shift in potential thereby decreasing over-potential for electro-oxidation of FA in comparison to bare carbon paste electrode. Under optimized conditions, a linear dynamic range of 4.0 x 10(-8) to 1.0 x 10(-3) M, with a lower detection limit of 3.0 x 10(-8) M (S/N = 3) was obtained. The surface morphology of the sensor was studied using field emission scanning electron microscopy and atomic force microscopy. EDX was used determine the elemental composition of the electrode. The electrochemical impedance study revealed the least charge transfer resistance for the modified electrode. The effect of variation of scan rate, pH and concentration towards the electro-catalytic oxidation of FA was also investigated. Absence of peak for interfering molecules like Ascorbic acid, Uric acid and Glucose makes this sensor unique with significant analytical advantage. The fabricated sensor revealed adequate reproducibility, long term stability and enhanced selectivity in presence of commonly existing interfering molecules. The sensor was employed for the validation of spiked human urine and the wine which gave recoveries ranging from 97.5 to 99.4%, making it a potential alternative tool for the quantitative detection of FA in the biomedical field.
引用
收藏
页码:22 / 31
页数:10
相关论文
共 50 条
  • [1] Carbon paste modified with Bi decorated multi-walled carbon nanotubes and CTAB as a sensitive voltammetric sensor for the detection of Caffeic acid
    Erady, Veera
    Mascarenhas, Ronald J.
    Satpati, Ashis K.
    Bhakta, Arvind K.
    Mekhalif, Zineb
    Delhalle, Joseph
    Dhason, A.
    MICROCHEMICAL JOURNAL, 2019, 146 : 73 - 82
  • [2] Multi-walled carbon nanotube modified carbon paste electrode as a sensor for the amperometric detection of L-tryptophan in biological samples
    Thomas, Tony
    Mascarenhas, Ronald J.
    D'Souza, Ozma J.
    Martis, Praveen
    Dalhalle, Joseph
    Swamy, B. E. Kumara
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2013, 402 : 223 - 229
  • [3] Multi-walled carbon nanotube modified carbon paste electrode as an electrochemical sensor for the determination of epinephrine in the presence of ascorbic acid and uric acid
    Thomas, Tony
    Mascarenhas, Ronald J.
    Martis, Praveen
    Mekhalif, Zineb
    Swamy, B. E. Kumara
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (06): : 3294 - 3302
  • [4] Voltammetric determination of phenylephrine hydrochloride using a multi-walled carbon nanotube-modified carbon paste electrode
    Zhou, Q.
    Zhai, H. Y.
    Pan, Y. F.
    ROYAL SOCIETY OPEN SCIENCE, 2018, 5 (12):
  • [5] Multi-walled Carbon Nanotube Modified Carbon Paste Electrode for the Voltammetric Determination of Folic Acid and Uric Acid
    Rekha
    Swamy, Bahaddurghatta Eshwaraswamy Kumara
    Ganesh, Pattan Siddappa
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (05): : 647 - 656
  • [6] Amperometric sensor based on multi-walled carbon nanotube and poly (Bromocresol purple) modified carbon paste electrode for the sensitive determination of L-tyrosine in food and biological samples
    Shrestha, Siddharth
    Mascarenhas, Ronald J.
    D'Souza, Ozma J.
    Satpati, Ashis K.
    Mekhalif, Zineb
    Dhason, A.
    Martis, Praveen
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 778 : 32 - 40
  • [7] Application of Multi-walled Carbon Nanotube Modified Carbon Ionic Liquid Electrode for the Voltammetric: Detection of Dopamine
    Qu, Li-Ning
    Wu, Jie
    Sun, Xiao-Ying
    Xi, Meng-Ying
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (4A) : 701 - 707
  • [8] Multi-walled carbon nanotube/poly(glycine) modified carbon paste electrode for the determination of dopamine in biological fluids and pharmaceuticals
    Thomas, Tony
    Mascarenhas, Ronald J.
    Swamy, B. E. Kumara
    Martis, Praveen
    Mekhalif, Zineb
    Sherigara, B. S.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 110 : 458 - 465
  • [9] Poly(sulfosalicylic acid)/multi-walled Carbon Nanotube Modified Electrode for the Electrochemical Detection of Catechol
    Liang, Yongqing
    Li, Jian
    Zhao, Yanjun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (10): : 9512 - 9522