Comparison of four commercial viral load techniques in an area of non-B HIV-1 subtypes circulation

被引:9
作者
Ndiaye, Ousseynou [1 ]
Diop-Ndiaye, Halimatou [1 ]
Ouedraogo, Abdou Salam [2 ]
Fall-Malick, Fatim Zahra [1 ]
Sow-Sall, Amina [1 ]
Thiam, Moussa [1 ]
Diouara, Abou Abadallah Malick [1 ]
Ndour, Cheikh Tidiane [1 ]
Gaye-Diallo, Aissatou [1 ]
Mboup, Souleymane [1 ]
Toure-Kane, Coumba [1 ]
机构
[1] Univ Cheikh Anta Diop Dakar, Lab Bacteriol Virol, CHU A Dantec, Dakar, Senegal
[2] Univ Ouagadougou, CHU Souro Sanou, Serv Bacteriol Virol, Bobo Dioulasso, Burkina Faso
关键词
HIV-1; Viral load; Comparison; GENETIC DIVERSITY; RNA QUANTITATION; MONITOR V1.5; TAQMAN HIV-1; ASSAYS; PERFORMANCE; AMPLICOR; FAILURE; RESISTANCE; INFECTION;
D O I
10.1016/j.jviromet.2015.06.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this study was to compare four HIV-1 viral quantitation platforms, Nuclisens EasyQ v2.0 (R) (EQ), COBAS AmpliPreP/Cobas Tagman (R) HIV-1 test v 2.0 (CTM), GENERIC HIV CHARGE VIRALE (R) (GEN), with Abbott Real Time HIV-1 (R) (m2000sp/rt) as reference technique. The study had first evaluated m2000sp/rt performances and then compared quantitation between techniques. Discordant samples were genotyped on gag and pal gene and sequences were analyzed using Sequence locator and SeqPublish to detect eventual mismatches. Performance analysis of m2000sp/rt showed good results with coefficients of variation values (CV) of 1.35%, 0.65%, and 0.54% for repeatability testing of low, intermediate and high concentrations, respectively. Reproducibility tests showed low CV values with 2.36% and 1.42% for low and high concentration levels, respectively and contamination test was very low value with 0.94%. Correlation and concordance between techniques ranged from r(2) = 0.98 and bias = -0.00185 (for m2000sp/rt vs CTM) to r(2) = -0.90 and bias = -0.135 (for EQ vs GEN). Discrepancies were observed on 37 samples mostly CRF02_AG but despite some mismatches, sequence analysis (26/37) did not show any remarkable differences between CRF02_AG queries and references. This study showed good correlation and good concordance between techniques. However, EQ yielded under-quantitation of CRF02_AG. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 131
页数:10
相关论文
共 50 条
  • [31] Comparison of three commercial assays for the quantification of HIV-1 RNA in plasma from individuals infected with different HIV-1 subtypes
    Chew, CB
    Herring, BL
    Zheng, F
    Browne, C
    Saksena, NK
    Cunningham, AL
    Dwyer, DE
    JOURNAL OF CLINICAL VIROLOGY, 1999, 14 (02) : 87 - 94
  • [32] Tissue culture drug resistance analysis of a novel HIV-1 protease inhibitor termed PL-100 in non-B HIV-1 subtypes
    Asahchop, Eugene L.
    Oliveira, Maureen
    Brenner, Bluma G.
    Martinez-Cajas, Jorge L.
    Toni, Thomas d'Aquin
    Ntemgwa, Michel
    Moisi, Daniela
    Dandache, Serge
    Stranix, Brent
    Tremblay, Cecile L.
    Wainberg, Mark A.
    ANTIVIRAL RESEARCH, 2010, 87 (03) : 367 - 372
  • [33] Increase of non-B subtypes and recombinants among newly diagnosed HIV-1 native Spaniards and immigrants in Spain
    Holguin, Africa
    de Mulder, Miguel
    Yebra, Gonzalo
    Lopez, Marisa
    Soriano, Vincent
    CURRENT HIV RESEARCH, 2008, 6 (04) : 327 - 334
  • [34] Development of a cost-effective assay for genotyping of HIV-1 non-B subtype for drug resistance
    Ammaranond, Palanee
    Sanguansittianant, Sayompoo
    Raju, Paul A.
    Cunningham, Philip
    Horthongkham, Navin
    JOURNAL OF VIROLOGICAL METHODS, 2014, 199 : 102 - 107
  • [35] Prevalence and resistance mutations of non-B HIV-1 subtypes among immigrants in Southern Spain along the decade 2000-2010
    de Felipe, Beatriz
    Perez-Romero, Pilar
    Abad-Fernandez, Maria
    Fernandez-Cuenca, Felipe
    Martinez-Fernandez, Francisco J.
    Trastoy, Monica
    del Carmen Mata, Rosario
    Lopez-Cortes, Luis F.
    Leal, Manuel
    Viciana, Pompeyo
    Vallejo, Alejandro
    VIROLOGY JOURNAL, 2011, 8
  • [36] Diagnostic accuracy of ultrasensitive heat-denatured HIV-1 p24 antigen in non-B subtypes in Kampala, Uganda
    Spacek, L. A.
    Lutwama, F.
    Shihab, H. M.
    Summerton, J.
    Kamya, M. R.
    Ronald, A.
    Laeyendecker, O.
    Quinn, T. C.
    Mayanja-Kizza, H.
    INTERNATIONAL JOURNAL OF STD & AIDS, 2011, 22 (06) : 310 - 314
  • [37] HIV-1 non-B subtypes: High transmitted NNRTI-resistance in Spain and impaired genotypic resistance interpretation due to variability
    Yebra, G.
    de Mulder, M.
    del Romero, J.
    Rodriguez, C.
    Holguin, A.
    ANTIVIRAL RESEARCH, 2010, 85 (02) : 409 - 417
  • [38] Presence of multiple non-B subtypes and divergent subtype B strains of HIV-1 in individuals infected after overseas deployment
    Lasky, M
    Perrett, JL
    Peeters, M
    BibolletRuche, F
    Liegeois, F
    Patrel, D
    Molinier, S
    Gras, C
    Delaporte, E
    AIDS, 1997, 11 (01) : 43 - 51
  • [39] Problems in the interpretation of HIV-1 viral load assays using commercial reagents
    O'Shea, S
    Chrystie, I
    Cranston, R
    Mullen, J
    Corbett, K
    Murphy, G
    Parry, JV
    De Ruiter, A
    Banatvala, J
    JOURNAL OF MEDICAL VIROLOGY, 2000, 61 (02) : 187 - 194
  • [40] A review on new commercial methods for HIV-1 and HCV viral load determinations
    Aguilera, Antonio
    Gonzalez Alba, Jose Maria
    Martinez Lamas, Lucia
    Moldes Suarez, Maria Luz
    Carlos Galan, Juan
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2010, 28 : 62 - 67